Page 11

Operating Instructions

Product description

Chapter 3

CLP100 Bar Code Reader

3

Product description This chapter describes the design, the features and the functions of the CLP100. ¾

3.1

For installation, electrical installation and startup assistance as well as for the application-specific configuration of the CLP100 using the CLP Setup configuration software, please read this chapter prior to carrying out any of the tasks.

Design

The CLP100 consists of an optical system with CCD line and an electronic unit with integrated decoder. All components are loctated in an industry-compatible housing (enclosure rating IP 40). The light exits and enters via a reading window in the housing. For an adaptation to on-site space conditions two housings are available: a housing with front reading window and a housing with side reading window. Via the integrated angle attachment, the reflected light enters through the side reading window at an angle of 90°, referred to the centre-line of the housing. Two LEDs on the rear of the CLP100 indicate the status depending on the operating mode. Depending on the type, the CLP100 is electrically connected by a shielded cable with a D-Sub plug or with an open end.

8008912/R289/2008-11-28

© SICK AG · Division Auto Ident · Germany · All rights reserved

11

Page 12

Product description

Chapter 3

Operating Instructions CLP100 Bar Code Reader

3.1.1

! !

View of device

"

§

! !

$

! !

$

Legend:

! Threaded hole M3, 2.5 mm deep " Connection cable § Reading window $ LED (status display) Fig. 3-1:

Design of the CLP100 with front end reading window

! !

"

§

Legend:

! Threaded hole M3, 2.5 mm deep " Connection cable § Reading window $ LED (status display) Fig. 3-2:

12

Design of the CLP100 with side reading window

© SICK AG · Division Auto Ident · Germany · All rights reserved

8008912/R289/2008-11-28

Page 13

Operating Instructions

Product description

Chapter 3

CLP100 Bar Code Reader

3.1.2

Scope of delivery

Delivery of the CLP100 includes the following components: No.

Component

Comment

1

CLP100 bar code reader

Type depends on version, see Table 3-2

1

Notes on device with electrical connection dia- Included in the device packing of the gram and quick start as primary information CLP100

1

CD-ROM "Manuals & Software Bar Code Scan- Included in the device packing of the ners" CLP100 CLP100 Operating Instructions in printed form, in German and/or English

Optional, depending on the number of issues explicitly ordered upon purchase

Table 3-1: CLP100 delivery

3.1.3 • • • Important

Contents of the CD-ROM (no. 2029112)

CLP Setup: Configuration software for standard PC (WindowsTM) with integrated online help system CLP Setup Help (HTML files) CLP100 operating instructions: PDF version in German and English as well as further publications of other SICK devices (connection modules, bar code scanners) Adobe Reader: Freely available PC software for displaying PDF files

All current versions of publications and programs on the CD-ROM can also be downloaded at www.sick.com. 3.1.4

Variants

At present the CLP100 is available in the following variants: Device

Order no.

Reading window

Connection

CLP100-0010

1018331

Front

9-pin D-Sub plug

CLP100-2010

1018332

Side

9-pin D-Sub plug

CLP100-0110

1018333

Front

Open cable end

CLP100-2110

1018334

Side

Open cable end

Table 3-2: Variants of the CLP100

3.1.5

System requirements

The following are required to start-up and operate the CLP100: •

A supply power pack with a stabilised output voltage of 5 V DC ± 5 % in accordance with IEC 60364-4-41 (functional extra-low voltage) and at least 2 W power output

•

In the case of external reading pulsing via the "Sensor" switching input: A suitable sensor for signaling an object with bar code, for example, a photoelectric reflex switch

•

A PC as followed: – Min. 80486, 66 MHz, 16 MB RAM, CD drive, a serial port (COM x), mouse (recommended), colour screen (resolution min. 800 x 600 pixel) – Operating system Windows 95TM/98TM, Windows NTTM, Windows 2000TM or Windows XPTM. – Free space available on the hard disk: approx. 6.5 MB

8008912/R289/2008-11-28

•

An RS 232 data connection cable (null modem, TxD and RxD transposed)

•

In order to install the CLP Setup configuration software and to use the CLP Setup Help online help system an HTML browser, for example, Internet ExplorerTM.

© SICK AG · Division Auto Ident · Germany · All rights reserved

13

Page 14

Chapter 3

Product description

Operating Instructions CLP100 Bar Code Reader

3.2

Product features and functions (overview)

Feature

Characteristic

High-performance bar code reader

• • • • •

Optical system with CCD line and integrated LED illumination Fixed focus Front reading window or side reading window Resolution 0.15 to 1.0 mm (5.9 mil to 39.5 mil), reading range (DOF) see Fig. 9-1, Page 44 Scanning/decoding frequency 500 Hz

Safety and user-friendly features

• • • •

Robust, compact metal housing, CE certification LED class 1 Automatic self-test on startup Low power consumption

Easy configuration

• Configuration (online/offline) via CLP Setup configuration software with integrated help system • Configuration alternatively with simple command strings, also for use with special devices • Two status LEDs

Operating modes

• • • •

Reading pulse

• External reading pulse, via switching input(s) or serial data interface (command)

Bar code evaluation

• • • •

Data communication

• Host interface: variable output format for reading result • Auxiliary interface (auxiliary data interface): same output format as on host interface

Electrical interfaces

• • • •

Connection technology (design)

• Data and switching interfaces as well as power supply: – Cable with 9-pin D Sub plug or – Cable with open end

Reading mode Diagnostic mode Adjusting mode Online test mode All standard bar code types Max. 10 codes per reading pulse Code length max. 32 digits (depends on number of codes per reading pulse) Code comparison (one matchcode)

Host interface (RS 232), variable data transfer rate and protocol Auxiliary interface (RS 232 TTL), same data transfer rate and protocol as on host interface One digital switching input for external reading pulse One digital switching output for signaling the reading status

Table 3-3: Overview of the product features and functions

14

© SICK AG · Division Auto Ident · Germany · All rights reserved

8008912/R289/2008-11-28

Page 15

Operating Instructions

Product description

Chapter 3

CLP100 Bar Code Reader

3.3

Working method of the device

The CCD bar code reader CLP100 detects bar codes in an illuminated scan field (scan line) and decodes the bar codes. The CLP100 transmits this data via the serial host interface to a host/PC for further processing. Refer to Fig. 3-3 for an overview of the functionality of the CLP100.

--- Cable if required Fig. 3-3:

Function of the CLP100

The CLP100 derives useful data for diagnostics from the reading processes. The quality of the reading data can be checked in the diagnosis mode. The CLP100 requires suitable pulsing (triggering) in order to start a reading process when there is an object in the reading area. This results in a time window for the reading process being opened in the CLP100. Triggering is carried out either with an external sensor or with a command string via the host interface. Both options are active in the default setting. The switching input ("Sensor" input) informs the CLP100 when it must start a reading process. The switching output ("Result" output) can have result functions assigned to them and triggers external devices such as, for example, a PLC input.

3.4

Display and operating elements

The CLP100 is operated or configured via the host interface by using the CLP Setup PC software or with command strings. The CLP100 is adapted to various applications by means of parameterization. The CLP Setup software is used, for example, to carry out the following settings: •

Configuration of the code types to be read

•

Read, evaluation and output properties

•

Communication parameters of the host interface

•

Structure of the data output strings of the host interface

•

Function of the auxiliary interface (terminal interface)

Chapter 10.2, Page 46 describes the installation and handling of the CLP Setup software. The procedure for configuring the CLP100 with the software is explained in Chapter 6.4, Page 30.

8008912/R289/2008-11-28

© SICK AG · Division Auto Ident · Germany · All rights reserved

15

Page 16

Chapter 3

Product description

Operating Instructions CLP100 Bar Code Reader

An LED status display ("Monitor") with two LEDs (red and green) on the rear of the CLP100 indicates the current operating state of the device. The meaning of the display for the respective operating mode is shown in Table 3-4. The display can be parameterized differently in some operating modes. The table lists all the possible meanings. :

Operating mode

Display

Function

Start

Green/red

• Light up during the switching on phase if the self-test is successful • Extinguish when changing to the read standby state

Reading mode

Green/red

• Light up when the signal for reading is given, until the beginning of the next reading cycle

Green

• Lights up after successful reading ("Good Read")

Red

• Extinguishes after successful reading ("Good Read")

Green

• Extinguishes after unsuccessful reading ("No Read")

Red

• Lights up after unsuccessful reading ("No Read")

Adjusting mode

Matchcode operation Green/red

• Extinguish, when there was no signal for reading and there is no read result

Red

• Lights up at "No Read" or "Read & No Match" or in accordance with the parameterization • Lights up at "No Read" or "Read & Match"

Green

• Lights up at "Read & Match" or in accordance with the parameterization • Lights up at "Read & No Match"

Table 3-4: Meaning of the LEDs

16

© SICK AG · Division Auto Ident · Germany · All rights reserved