Installation This chapter describes the installation sequences for the CLP100.
4.1
Installation sequence
The typical installation sequences are listed below: •
Select the installation site for the CLP100
•
Connect the power supply
•
Align the CLP100 to the bar code
•
Install the CLP100
•
Adjust the CLP100
•
Install the external sensor for the reading pulse
NOTICE Claims under the warranty rendered void! Do not open the housing of the CLP100. If the device is opened, the SICK AG warranty shall not apply.
4.2
Preparations for installation
The following general requirements should be observed for installation: •
Typical space requirement: application-specific and type-dependent (reading range, orientation of reading window)
•
Unobstructed view of the objects for the CLP100
•
Stable installation holder with sufficient load capacity and dimensions suited to the CLP100 (see Chapter 9.3 Dimensional drawings, Page 45)
•
Shock absorbent and vibration free attachment
The following tools and resources are required for installation: •
2 screws M3 for fixing the CLP100 to the installation site, Screw length depends on the wall thickness of the base. Screws may not be screwed more than 2.5 mm (0.1 in) into the CLP100
•
Tool
•
Measuring tape
•
Angulometer
4.2.1 •
Laying out the components to be installed ready
CLP100 bar code reader
4.2.2
Threaded holes
The CLP100 is fastened by means of two threaded holes (M3) to the top or bottom of the device (Fig. 4-1, Page 18). The complete housing dimensions are shown in Chapter 9.3 Dimensional drawings, Page 45.
8008912/R289/2008-11-28
© SICK AG · Division Auto Ident · Germany · All rights reserved
17
Page 18
Chapter 4
Installation
Operating Instructions CLP100 Bar Code Reader
! ! Fig. 4-1:
Position of the threaded holes !at CLP100
4.3
Installation site
! !
The following aspects are relevant for the selection of the installation location: •
Reading distance to the code/field of view dimensions
•
Angle alignment of the CLP100
•
Avoiding surface reflections
When selecting the installation site take the distance between the CLP100 and the host. 4.3.1
Distance between the CLP100 and the host
The maximum distance between the CLP100 and the host when extension cables are used amounts to 12 m (39.37 ft) (host interface RS 232). 4.3.2
Distance between the CLP100 and the bar code/field of view dimensions
The distance a between the reading window of the CLP100 and the bar code must amount to 20 to 70 mm (0.79 to 2.76 in) depending on the width of the bar code (see Fig. 4-2). Chapter 9.2 Reading field diagram, Page 44 shows the width of the reading area of the CLP100 in relation to the reading distance for various resolutions (module widths).
a Fig. 4-2:
18
Reading distance to the object
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 19
Operating Instructions
Installation
Chapter 4
CLP100 Bar Code Reader
Angle alignment of the CLP100 The angle between the scan line and bar code is selected, so that a good reading is possible. The optimum alignment of the CLP100 is reached at an angle of 90° between the scan line and the bar code bars (see Fig. 4-3). Possible reading angles which can arise between the scan line and the bar code bars must be taken into consideration (see Fig. 4-4 and Table 4-1).
Fig. 4-3:
90° angle between the scan line and the bar code bars
Fig. 4-4:
Reading angle occurring between the scan line and the bar code bars
Angle
Limit
Tilt α
0° ± 2°
Pitch β
0° ± 5°
Skew γ
10° ± 5°
Table 4-1: Permissible angle occurring between the scan line and the bar code bars
8008912/R289/2008-11-28
© SICK AG · Division Auto Ident · Germany · All rights reserved
19
Page 20
Installation
Chapter 4
Operating Instructions CLP100 Bar Code Reader
Important
If the light of the scan line falls exactly vertically on the surface of the bar code, disturbing reflections can occur when the reflected light is received. In order to avoid this effect the CLP100 must be installed so that the emitted light is tilted relative to the perpendicular (see Fig. 4-5). Front end reading window
Side reading window 10° 10° Bar code
Reading Distance
Fig. 4-5:
20
8
15
Bar code
Reading Distance
Angle between the emitted light and the bar code (tilted to the perpendicular)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 21
Operating Instructions
Installation
Chapter 4
CLP100 Bar Code Reader
4.4
Installation and adjustment of the device
4.4.1
Installing the CLP100
1.
Align the CLP100 so that the angle between the scan line and the bar code bars amounts to 90°. Take any possible reading angle occurring into consideration (see Fig. 4-4, Page 19).
2.
In order to avoid disturbing reflections align the CLP100 so that the emitted light impacts on the bar code at an angle of 100° (see Fig. 4-5, Page 20 and Fig. 4-6).
NOTICE Damage to the device! The screws may not be screwed more than 2.5 mm (0.1 in) into the CLP100. Longer screws may damage the device. ¾
Use screws with a suitable length.
3.
Screw the screws through the base to which the CLP100 is fastened into the threaded hole.
4.
Tighten the screws slightly.
5.
Adjust the CLP100 as described below.
a b 100°
Fig. 4-6:
4.4.2
100°
Adjustment of the CLP100 in order to avoid reflections; a: With front end reading window, b: With side reading window
Adjusting the CLP100
The adjusting operating mode supports the adjustment of the CLP100. In this operating mode the green LED extinguishes if the reading process fails ("No Read"). If the green LED does not light up, the CLP100 cannot read the bar code. If the green LED flickers, the CLP100 can only read the bar code badly. If the green LED shows steady light, the CLP100 is aligned optimally. The scanning frequency in adjusting mode amounts to 500 Hz. 1. Connect the CLP100 to the supply voltage and switch on the supply voltage. 2. Connect the CLP100 to the PC. 3. Start the CLP Setup configuration software (see Chapter 10.2, Page 46). 4. In the CLP Setup select the DEVICE CONFIGURATION tab card. 5. Click in the OPERATING MODE field and select ADJUSTING MODE. 6. Click in the LED DISPLAY field and select NO READ/GOOD READ. 7. Carry out the download to the CLP100 (see Chapter 6.4.1, Page 31).
8008912/R289/2008-11-28
© SICK AG · Division Auto Ident · Germany · All rights reserved
21
Page 22
Chapter 4
Installation
Operating Instructions CLP100 Bar Code Reader
8. Guide objects with bar codes realistically into the reading area of the CLP100. Ensure that the permitted reading angle is not exceeded. 9. Start the reading pulse: Cover the optical path of the sensor or make connection (see Chapter 4.5, Page 22). 10. Align the CLP100 so that the green LED lights up steadily as far as possible (reading result "Good Read"). 11. Tighten the screws. The CLP100 is aligned optimally to the bar code.
4.5
Installing the reading-pulse sensor
If the CLP100 is triggered via an external sensor, the sensor and a reflector have to be installed near the CLP100. Fig. 4-7 shows an example of the installation site of the sensor.
a b Fig. 4-7:
1.
Install the reading-pulse sensor at the installation site.
2.
Connect the reading-pulse sensor to the CLP100 (see Chapter 5.4.4, Page 27).
3.
Call up the CLP Setup and check the read result with the terminal emulator (see Chapter 6.4, Page 30).
4.
Check whether the reading process of the CLP100 is synchronized with the incoming objects.
4.6
22
Installation site for the reading-pulse sensor and the reflector (b smaller than a)
Disassembling the device
1.
Switch off the supply voltage.
2.
Disconnect the cable connection.
3.
Screw off the CLP100.
4.
Dispose of the CLP100 ecologically friendly (see Chapter 7.4, Page 39)