Operating Instructions CLP100 Bar Code Reader: 5 Electrical installation
Pages 23 to 28 of 58, from Operating Instructions CLP100 Bar Code Reader
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLP100
Page 23
Operating Instructions
Electrical installation
Chapter 5
CLP100 Bar Code Reader
5
Electrical installation 5.1 Important
Overview of installation sequences
Electrical installation should only be carried out by qualified staff. The following list provides an overview of a typical installation sequence: •
Connecting the supply voltage
•
Wiring the host interface (Connecting the PC)
•
Wiring the "Sensor" switching input
•
Wiring the "Result" switching output
Once electrical installation has been completed, the CLP100 is started up and configured (see Chapter 6 Startup and configuration, Page 29).
5.2
Planning the electrical installation
The following general requirements should be observed for the electrical installation: •
Supply voltage 5 V DC ± 5 % (functional extra-low voltage in accordance with IEC 60364-4-41). The power supply unit must output a continuous output of 2 W and be provided by the customer using e.g. a supply power pack.
•
With external reading pulsing: Suitable reading pulse sensor (start/stop), e.g. photoelectric reflex switch, for registering an object in the field of view
•
Host computer with RS RS 232 data interface for further processing the reading data
The following toots and resources are required for electrical installation:
8008912/R289/2008-11-28
•
Tool
•
Digital measuring device (current/voltage measurement)
© SICK AG · Division Auto Ident · Germany · All rights reserved
23
Page 24
Chapter 5
Electrical installation
Operating Instructions CLP100 Bar Code Reader
5.3
Electrical connections and cables
The electrical connection of the CLP100 is carried out either via a 9-pin D-Sub cable plug or the open cable end. The cable length is 0.9 m (2.95 ft). 5.3.1
Pin assignment of the connection plug or wire colors of the cable end 1
5
6
9
Pin
Signal
1
Sensor
2
RxD (Host)
3
TxD (Host)
4
Result "GO/NG"
5
GND
6
Not assigned
7
RxD (Terminal), TTL
8
TxD (Terminal), TTL
9
+5 V
Table 5-1: Pin assignment of the D Sub plug
Wire color
Signal
Pink
Sensor
Brown
RxD (Host)
Gray
TxD (Host)
White
Result "GO/NG"
Black
GND
Yellow
RxD (Terminal), TTL
Orange
TxD (Terminal), TTL
Red
+5 V
Blue
RTS
Green
CTS
Table 5-2: Assignment of the wire colors of the open cable end
24
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 25
Operating Instructions
Electrical installation
Chapter 5
CLP100 Bar Code Reader
5.4
Carry out the electrical installation
NOTICE Claims under the warranty rendered void! Do not open the housing of the CLP100. If the device is opened, the SICK AG warranty shall not apply. •
Connect or disconnect current linkages only under de-energised conditions.
•
Wire cross sections and their correct protection have to be selected and implemented according to valid engineering standards.
•
For data connection use only shielded data cables (twisted pair).
•
In order to avoid interferences, do not install data cable parallel to the power- supply and motor cables over long distances (for example in cable ducts).
•
Lay all cables so that there is no possibility of people tripping over them and so that they are protected against damage.
5.4.1
Supply voltage
For operation the CLP100 requires a supply voltage of 5 V DC ± 5 % in accordance with IEC 60364-4-41 (functional extra-low voltage). The functional extra-low voltage can be generated by a power supply unit using a safety transformer . The power supply unit must output a continuous output of 2 W. Important
The output circuit of the power supply unit must be electrically insulated from the input circuit. This is usually created by means of a safety transformer in accordance with IEC 742. To ensure that the incoming supply cables are protected against short-circuits/overloads, the wire cross-sections must be dimensioned and protected in accordance with valid standards. Connecting the supply voltage: ¾
Connect the supply voltage to Pin 5 and Pin 9 of the 9-pin D Sub plug (see Table 5-1, Page 24) respectively to the wires of the open cable end (see Table 5-2, Page 24).
5.4.2
Wiring the host interface (Connecting the PC)
The CLP100 is operated and configured with the CLP Setup software. For this purpose it must be connected temporarily to the PC via the host interface. The host interface of the CLP100 is an RS 232 interface. For the pin assignment refer to Table 5-1, Page 24 or Table 5-2, Page 24. Table 5-3 shows the recommended maximum cable length as a function of the data transmission rate. .
Interface type
Transmission rate
Max. distance to the host
RS 232
Up to 19,200 Bd
12 m (39.37 ft)
Table 5-3: Maximum cable length between the CLP100 and the host computer
When the PC is connected, the communications parameters are set as described in Chapter 6.4.1 Transferring the parameter set between the CLP Setup and CLP100, Page 31.
8008912/R289/2008-11-28
© SICK AG · Division Auto Ident · Germany · All rights reserved
25
Page 26
Electrical installation
Chapter 5
Operating Instructions CLP100 Bar Code Reader
Fig. 5-1 shows the wiring of the host interface.
*) 9-pin internal D-Sub plug to PC
Fig. 5-1:
Wiring the host interface (RS 232)
NOTICE Damage to the interface module in the CLP100! Electronic components can be damaged if the host interface is wired incorrectly.
Recommendation
¾
Wire the host interface correctly in accordance with Fig. 5-1.
¾
Check the wiring before switching on the CLP100.
¾
Connect the host interface of the CLP100 EMC-compatibly to the host by means of shielded cables. Observe the maximum cable lengths (see Table 5-3, Page 25).
¾
Connect the shielding at one end.
1.
Switch off the PC and the supply voltage of the CLP100.
2.
Connect the desired port "COM x" of the PC to the CLP100. To this purpose use an RS-232 data connection cable (null modem, RxD and TxD transposed).
3.
Switch on the PC and the supply voltage of the CLP100.
4.
Set the communication parameters of the PC (see Chapter 10.2.3, Page 48). In the default setting the CLP100 communicates via the RS 232 interface with the host using the values listed in Table 5-4.
Parameter
Host interface value
Aux interface value
Data transmission rate
9,600 Bd
9,600 Bd
Data bit
8
8
Parity
None
None
Stop bit
1
1
Protocol
SICK: Sending start characters: STX Sending stop characters: ETX Repeat request: None Timeout: 50 ms
SICK: Sending start characters: STX Sending stop characters: ETX Repeat request: None Timeout: 50 ms
Table 5-4: Communication parameters of the host interface (default setting)
26
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 27
Electrical installation
Operating Instructions
Chapter 5
CLP100 Bar Code Reader
5.4.3
Wiring the auxiliary (terminal) interface
As an alternative the PC may be connected to the Aux interface which operates parallel to the host interface with the same communication parameter values. The Aux interface can be use e.g. to monitor the data traffic on the host interface. Fig. 5-2 shows the wiring of the Aux interface. Important
The terminal interface is a TTL level interface.
7
3*
8
2*
5
5*
*) 9-pin internal D-Sub plug to PC
Fig. 5-2:
Wiring the Aux interface (RS 232 TTL)
5.4.4
Wiring the "Sensor" switching input
If a reading process is to be triggered via an external sensor, connect the sensor to the "Sensor" switching input. This triggering type is selected as the default setting of the CLP100. Fig. 5-3 shows the wiring of the "Sensor" switching input. Table 5-5 lists the characteristic data of this switching input.
Fig. 5-3:
¾
Wiring of the "Sensor" switching input
Connect the sensor as shown in Fig. 5-3.
Switching behaviour
Connecting GND to the input starts the read port of the CLP100 (low)
Properties
Not electrically separated
Electrical values
Low (Reading gate active): 0 V ≤ VS ≤ 0.8 V I ≤ 1.5 V µA
High (Reading gate inactive): 2.4 V ≤ VS ≤ 5 V I ≤ 1.5 V µA
Table 5-5: Characteristic data of the "Sensor" switching input
TIP
8008912/R289/2008-11-28
The DEVICE CONFIGURATION tab card of the CLP Setup software can be used to modify the response time of the "Sensor" input (debouncing).
© SICK AG · Division Auto Ident · Germany · All rights reserved
27
Page 28
Electrical installation
Chapter 5
Operating Instructions CLP100 Bar Code Reader
5.4.5
Wiring the "Result" switching output
The switching output can have various result functions assigned to it. If the corresponding event occurs during a reading process, the switching output becomes live for the selected pulse duration. Fig. 5-4 shows the wiring of the "Result" switching output. Table 5-6 lists the characteristic data of the switching output.
Fig. 5-4:
¾
Wiring of the "Result" switching output (NPN)
Wire the switching output as described in Figure 5-4.
Switching behaviour
NPN switching against GND
Properties
Not electrically separated
Electrical values
Vout = 5 V ≤ V ≤ 30 V Iout = ≤ 50 mA
Table 5-6: Characteristic data of the "Result" switching output
Recommendation
TIP
28
¾
In order to check the switching functions wire the switching output to a load and measure the voltage with a high-voltage digital voltmeter. This avoids the display of incorrect voltage values and switching states.
The DEVICE CONFIGURATION tab card of the CLP Setup software can be used to modify the function assignment, the pulse duration and the output instant of the signal.