For the Sick CLP100

Page 6

Notes on this document

Chapter 1

Operating Instructions CLP100 Bar Code Reader

1

Notes on this document 1.1

Function

This document provides instructions for technical staff on the installation and operation of the CCD bar code reader CLP100 in the following versions: • front end or side reading window

• connection via cable with 9-pin D Sub plug or cable with open end

A summary of all device versions is given in Table 3-2, Page 13. The document contains information on •

Installation and electrical installation

•

Startup and configuration

•

Maintenance

•

Troubleshooting

•

Replacing the CLP100 bar code reader

All actions are described step-by-step. Important

The CLP100 bar code reader will all simply be called "CLP100" below.

1.2

Target audience

This document is intended for persons who are responsible for the following activities: Tasks

Target group

Installation, electrical installation, main- Qualified staff, e.g. electricians and service technicians tenance and replacement Startup and configuration

Qualified staff, e.g. technicians and engineers

Table 1-1: Target group of the document

1.3

Information content

This document contains all the information required for the installation, electrical installation and startup of the CLP100 with the default setting at the installation location. Configuration of the CLP100 for the application-specific reading conditions is carried out using the CLP Setup configuration software. The CLP Setup configuration software contains an online help system to facilitate configuration. Installation and use of the software are described in the appendix. Further information on the construction of the bar code reader as well as the bar code technology can be obtained from SICK AG, Auto Ident Division. On the Internet at www.sick.com.

6

© SICK AG · Division Auto Ident · Germany · All rights reserved

8008912/R289/2008-11-28

Page 7

Notes on this document

Operating Instructions

Chapter 1

CLP100 Bar Code Reader

1.4

Symbols used

To gain easier access, some information in this document is emphasised as follows:

NOTICE Notice! Indicates a potential risk of damage or impair on the functionality of the CLP100.

WARNING Warning notice! A warning noctice indicates real or potential danger. This should protect you against accidents. The safety symbol next to the warning notice indicates why there is a risk of accident. e.g. due to electricity. The warning levels (CAUTION, WARNING, DANGER) indicate the seriousness of the risk. ¾

Carefully read and follow the warning notices.

Reference

Italic script denotes a reference to further information.

Important

This important note informs you about specific features.

Recommendation TIP

A "Recommendation" provides information on how to carry out an action optimally. A "TIP" explains the setting possibilities in the CLP Setup configuration software. THIS FONT characterizes a term used in the user interface of the CLP Setup configuration software (for example, menu item, tab card).

¾

There is a procedure which needs to be carried out. This symbol indicates operational instructions which only contain one operational step or operational steps in warning notices which do not have to be followed in any particular order. Operational instructions comprising several steps are denoted using consecutive numbers.

8008912/R289/2008-11-28

© SICK AG · Division Auto Ident · Germany · All rights reserved

7

Page 8

Chapter 2

Safety information

Operating Instructions CLP100 Bar Code Reader

2

Safety information This chapter deals with your safety and operator safety in the operational area. ¾

Read this chapter carefully before using the CLP100.

2.1

Authorized users

The CLP100 must be installed and operated by qualified personnel in order to ensure that it functions correctly and safely.

NOTICE Repairs to the CLP100 should only be carried out by qualified and authorised SICK AG service staff. The following qualifications are required for the various activities: Tasks

Qualifications

Installation, maintenance

– General technical training – Knowledge of the standard guidelines relating to safety in the workplace

Electrical installation, replacement

– Practical electrical training – Knowledge of the common electrical safety guidelines – Knowledge regarding the operation of the devices in the relevant application (for example, packaging machines, clinical automatic analyzer, access control)

Startup, configuration

– Basis knowledge of the WindowsTM operating system – Basis knowledge of working with an HTML browser (e.g. Internet ExplorerTM) for using the online help – Basic knowledge of data transfer – Basic knowledge of bar code technology

Operation of the devices in – Knowledge regarding the operation and handling of the devices in each operational area the relevant application (for example, packaging machines, clinical automatic analyzer, access control) – Knowledge of the hardware and software environment of the relevant application Table 2-1: Required qualifications for starting up the CLP100

2.2

Intended use

The CLP100 is used for the automatic detection and decoding of bar codes. It is installed as a reading station and reads, for example, bar codes on objects of a clinical automatic analyser. The CLP100 transmits the decoded bar code information via its host interface to a host computer for further processing.

NOTICE Claims under the warranty rendered void! Any warranty claims against SICK AG shall be deemed invalid in the case changes to the CLP100, such as opening the housing, this includes modifications during installation and electrical installation or changes to the SICK software.

¾

8

Only operated the CLP100 in the permitted ambient air temperature range (see Chapter 9 Technical data, Page 43).

© SICK AG · Division Auto Ident · Germany · All rights reserved

8008912/R289/2008-11-28

Page 9

Operating Instructions

Safety information

Chapter 2

CLP100 Bar Code Reader

2.3 ¾

General safety instructions Read the general safety instructions thoroughly and observe them strictly at all activities at the bar code reader. This also applies to the warnings before the handling instructions in the individual chapters of this document.

2.3.1

LED illumination

CAUTION LED radiation! The illumination of the CLP100 operates with LEDs of LED class 1. Under normal and sensible conditions, the accessible radiation of the LEDs is not hazardous. The entire area of the reading window acts as a LED outlet aperture. Caution – use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Important

¾

Never look directly into the illumination.

¾

Do not open the housing. (Opening the housing does not deactivate the LEDs by the reading pulse.)

¾

Always observe the latest valid version of laser protection regulations.

The illumination LEDs operate at a wavelength of λ = 630 nm (visible red light). The product is classified in LED class 1 in accordance with EN/IEC 60825-1. Maintenance is not required to ensure compliance with LED class 1. 2.3.2

Electrical installation

NOTICE •

Electrical installation should only be carried out by qualified staff.

•

Connect or disconnect current linkages only under de-energised conditions.

•

Wire cross sections and their correct protection have to be selected and implemented according to valid engineering standards.

•

Observe the current safety regulations when working on eletrical systems.

2.4

Quick- Stop and Quick-Restart

The CLP100 can be switched on or off using the user’s main switch. 2.4.1 ¾

Switching off the CLP100

Switch off the supply voltage or remove the 9-pin D Sub plug.

At the most the last read result is lost. 2.4.2 ¾

Switching on the CLP100 again

Switch on the supply voltage or reconnect the 9-pin D Sub plug.

The CLP100 resumes operation with the last parameter set saved.

8008912/R289/2008-11-28

© SICK AG · Division Auto Ident · Germany · All rights reserved

9

Page 10

Chapter 2

Safety information

Operating Instructions CLP100 Bar Code Reader

2.5

Environmental information

The CLP100 is designed so that it harms the environment as little as possible. It does not contain or emit any substances harmful to the environment and is not a source of faults for, for example, coating wetting in paint shops. The maximum power consumption of the CLP100 amounts to 2 W. 2.5.1

Disposal after final removal from service

At present SICK AG does not take back devices which have become unusable or irreparable. ¾

Dispose of unusable or irreparable devices in accordance with the respective state regulations on waste disposal in a manner compatible with the environment.

The CLP100 design allows it to be separated into recyclable secondary raw materials (housing) and hazardous waste (electronic scrap). See Chapter 7.4, Page 39.

10