The text of a manual · part 10 of 10
Operating Instructions CLP100 Bar Code Reader: 10 Appendix
Pages 46 to 58 of 58, from Operating Instructions CLP100 Bar Code Reader
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLP100
Page 46
Appendix
Chapter 10
Operating Instructions CLP100 Bar Code Reader
10
Appendix 10.1
Appendix overview
•
Installation and handling of the CLP Setup software
•
Calculation of the number of scans
•
Calculation of the code length of a bar code
•
Command language for CLP100 bar code readers
•
Copy of the EC Declaration of Conformity (page 1)
10.2
Installation and handling of the CLP Setup software
The scope of delivery of the CLP100 includes a CD-ROM (“Manuals & Software“) with the CLP Setup software. A PC with the operating system Windows 95TM/98TM, Windows NTTM, Windows 2000TM or Windows XPTM as well as an HTML browser, e.g. Internet ExplorerTM is required in order to install and use the software. The memory requirement on the hard disk amounts to approx. 6.5 MB for the installation of CLP Setup and CLP Setup Help. 10.2.1 1.
Important
Preparing the installation
Have the CD ROM (“Manuals & Software“) at hand.
2.
Connect the PC to the host interface of the CLP100 (see Chapter 5.4.2, Page 25).
3.
Switch on the supply voltage of the CLP100.
4.
Switch on the PC and start Windows.
The following instructions describe how to install the software on Windows 95TM. These instructions may differ depending on the operating system you are using (for example, administrator rights are required to install the software on Windows NTTM). 10.2.2
Carrying out the installation
The installation can be carried out directly from the CD-ROM or after the software has been saved on your local hard disk. During the installation of CLP Setup the installation program creates a main directory with subdirectories and the required links. CLP Setup can be removed completely from the PC by using the Uninstaller which is automatically installed as well. First installation 1.
Shut down all the applications running in Windows.
2.
Insert the CD-ROM into the CD-ROM drive.
3.
If the auto run function is enabled, the start page (table of contents) of the CD-ROM is automatically displayed in the your browser.
4.
Select the SOFTWARE folder on top left.
5.
Select CLP SET-UP SOFTWARE in the listing. A table with CLP100 information is displayed.
6.
Select DOWNLOAD under SOFTWARE FILE .
7.
In the FILE DOWNLOAD dialog box select the option to install directly from the CD-ROM. Confirm with OK. - or -
46
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 47
Operating Instructions
Appendix
Chapter 10
CLP100 Bar Code Reader
Select the option to save the software locally on your local hard disk and confirm with OK. In the FILE DOWNLOAD dialog box select the desired target directory on your hard disk. The “CLPSetup.exe“ file is then saved at this location. Select OPEN in the dialog box to start the file. 8.
The installation program starts and guides you through the installation with screen messages. The CLP Setup software and the CLP Setup Help online help are installed.
9.
Observe the the latest information on the CLP Setup given in the Readme file.
10. Click on OK to confirm the final installation message. The CLP Setup software and the CLP Setup Help online help are installed and ready for use. Updating an installation There are two possibilities of installing a new version of CLP Setup: •
Installation of the new version in addition to the old version - or -
•
Installation of the new version instead of the old version (overwriting)
Installation of the new version in addition to the old version When the new version is installed in addition to the old version the new CLP Setup software is installed as described under First installation. When prompted for the target directory you have to enter a new directory. Both software versions are available parallel, but may not be started simultaneously. The configuration files of the old version can continue to be used in the new version. Installation of the new version instead of the old version When the new version is installed instead of the old one, the files of the old version have to be removed – with the exception of the configuration files "*.slp". The "*.slp" files contain the parameter sets of the CLP100. The Uninstaller removes the program files. The Uninstaller can be used to remove either all the files (with the exception of the configuration files) or only selected files. The default setting is the complete removal (the configuration files are not removed). In the case of userspecific removal the files are listed and only the selected files are removed. When selecting files ensure that the main directory together with the "*.slp" files is not deleted. 1.
Select the Uninstaller for CLP Setup in the start menu of Windows under PROGRAMS. The Uninstaller starts and guides you through the removal with screen messages.
2.
Select the type of removal (complete or user-specific).
3.
The new version of CLP Setup is installed as described under First installation. Select the same directory. The new version of CLP Setup is installed. The configuration files of the old version can continue to be used.
8008912/R289/2008-11-28
© SICK AG · Division Auto Ident · Germany · All rights reserved
47
Page 48
Chapter 10
Appendix
Operating Instructions CLP100 Bar Code Reader
10.2.3
Starting the CLP Setup software
The CLP Setup software starts with the following default setting: Communication
COM 1, 9,600 Bd, 8 data bits, 1 stop bit, no parity
Linear measures
Metric
Language
English
Browser
Not assigned
Directory for files
"Data" (configuration files for CLP100)
Table 10-1: Default settings of CLP Setup
1.
Switch on the PC and start Windows.
2.
Select CLP Setup in the start menu. The introductory dialog box is displayed after the identifier for the SICK software.
3.
Click on OK. CLP Setup checks whether a bar code reader is connected to the port "COM 1" of the PC and whether the values of the communication parameters between the bar code reader and the PC agree. If the values agree, CLP Setup enters CONNECTED in the top right-hand of the status bar. The software loads the internal description of the bar code reader and the default setting of the parameters from the database and displays it in the tab cards. Then the software copies the last set saved permanently in the CLP100 from the CLP100. Afterwards this is displayed in the tab cards. The current parameter set can be edited in the tab cards.
Help in cases of problems If the CLP Setup displays the message NO CONNECTION in the top right-hand of the status bar, the software could not establish a connection to the CLP100. This can have two causes. The CLP100 is not connected, or the communication parameters of the CLP100 and the PC do not agree.
48
1.
Connect the PC to the host interface of the CLP100 as described in Chapter 5.4.2, Page 25.
2.
Click on . The AUTO BAUD DETECT dialog box is displayed. CLP Setup checks whether a bar code reader is connected to the port "COM 1" of the PC and whether the values of the communication parameters between the bar code reader and the PC agree. If the values agree, the CLP Setup displays the values of the communication parameters.
3.
If CLP Setup still cannot establish a connection, click on CANCEL and select the SERIAL INTERFACE menu item in the OPTIONS menu. CLP Setup displays the current settings of the communication parameters.
4.
Set the following communication parameters: Connected COM port, 9,600 Bd, 8 data bits, 1 stop bit, no parity.
5.
Click on OK.
6.
Click on . The AUTO BAUD DETECT dialog box is displayed. CLP Setup attempts again to communicate with the CLP100. If this is successful, CLP Setup displays the values of the communication parameters between the bar code reader and the PC.
7.
Click on OK. The dialog box prompts you whether the parameters of the device are to be loaded.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 49
Operating Instructions
Appendix
Chapter 10
CLP100 Bar Code Reader
8.
In order to copy the current parameter set to the CLP Setup click on YES. CLP Setup displays CONNECTED. The current parameter set can be edited in the tab cards.
10.2.4
User interface
The user interface is largely self-explanatory. The online help describes how to use the user interface under HELP in the menu item PROGRAM INFORMATION. Fig. 10-1 shows a view of the user interface. The user interface consists of the following elements:
Fig. 10-1:
•
Title bar displaying the program name (CLP Setup) and the current configuration file
•
Menu bar with pull-down menus
•
Toolbar with icons which trigger a function when clicked on
•
Status bar (top right) with scanner selection field and status field for displaying the connection to the bar code reader
•
3 tab cards (READING CONFIGURATION, DEVICE CONFIGURATION, HOST INTERFACE). Further dialog boxes are opened in the tab cards, if necessary
User interface of the CLP Setup software
8008912/R289/2008-11-28
© SICK AG · Division Auto Ident · Germany · All rights reserved
49
Page 50
Chapter 10
Appendix
Operating Instructions CLP100 Bar Code Reader
10.2.5
Functions
The CLP Setup software provides the following functions: Group
Function
Communication
• • • •
Display
• Selecting the display language • Selecting the units of measure • Displaying the last 10 configuration files that were processed
Operation
• Modifying the parameter/parameter values on the tabs • Online access to the CLP100 via a Terminal Emulator (selecting operating mode, configuring with commands, starting reading process) • Context-sensitive help via the [F1] key
Upload/Download
• Uploading and displaying parameter set stored in the CLP100 • Downloading and saving the changes to the parameter set in the CLP100
Administration
• • • • •
Export
• Exporting the configuration files in RTF format
Printing
• Printing the configuration files
Automatic communication attempt with the CLP100 when the program is started AutoBaud detect for automatic serial communication establishment with the CLP100 Selecting the COM port of the PC for adapting the data transfer parameters Automatic software compatibility check in the CLP100
Loading the default setting of the parameter set from the database of CLP Setup Saving the changes to the parameter set as a configuration file "*.slp" Automatic storage confirmation prompt when changes are made to the configuration file Setting switches in the "dpmain.ini" file for starting the program Starting program with SLP file as argument
Table 10-2: Functions of the CLP Setup configuration software (overview)
10.2.6
Using the CLP Setup Help on-line help
The CLP Setup Help on-line help helps you in using the CLP Setup software. The help runs under an HTML browser (for example, Microsoft Internet-ExplorerTM). The help can be called up context-specifically for the parameter being edited and describes the function of the parameter and possible values for the parameter. ¾
Press [F1] key. The browser window opens and the help topic is displayed.
¾
If the browser is not found, select CHOOSE BROWSER in the HELP menue and enter the path for the browser in the opened dialog box.
¾
In order to avoid multiple opening of the browser use the key combination [Alt]+ [Tab] or the Windows status bar to toggle between the CLP Setup and the CLP Setup Help.
¾
In order to call up the help overview click on the CONTENTS menu item under HELP in the menu bar of the CLP Setup.
In the upper horizontal frame it is possible to also click on a tab tard. The parameters are then displayed in the left-hand vertical frame. These can be selected by clicking on them.
50
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 51
Operating Instructions
Appendix
Chapter 10
CLP100 Bar Code Reader
10.3
Calculation of the number of scans
The maximum possible number of scans for a bar code depends on the transporting speed v. Fig. 10-2 show one calculation example for the possible number of scans at ladder positionings of the bar code bars. s v = -t
IS lS v = --------------------n ⋅ t Scan with
1 t Scan = -f lS v = --- ⋅ f n lS n = --- ⋅ f v v Specified values: Number of scans n = ? Transporting speed v = 1.5 m/s Bar length lS = 20 mm Scanning frequency f = 500 Hz Coding 100 % readable Fig. 10-2:
Important
8008912/R289/2008-11-28
0.02 m 1 n = ---------------- ⋅ 500 -m s 1.5 ---s n = 6.7 ⇒ n = 6 Recommended minimum value n = 5
Calculation example: Number of scans for ladder positioning of the bar code bars
Picket fence orientation of the bar code labels is only feasible in stand still situations or slow movement of the object.
© SICK AG · Division Auto Ident · Germany · All rights reserved
51
Page 52
Appendix
Chapter 10
Operating Instructions CLP100 Bar Code Reader
10.4
Calculation of the code length of a bar code
The code length of a bar code corresponds to the number of used characters in the printing image including the check digits (if they exist). The fixed code length can be specified in the CLP Setup. The code length can be determined by counting the bars and gaps if the code type of a bar code is known. The respective equation for calculation is shown in Table 10-3. 1.
Count the bars and possibly gaps as specified in Table 10-3. Also count the start and stop characters.
2.
Calculate the code length in accordance with the equation specified in the table.
3.
Carry out the input in the CLP Setup as specified in Column 4 of Table 10-3. Calculation of the code length1)2)
Input in the CLP Setup
Number of bars
Number – 10 I Code = ------------------------------------------5
Calculated code length
2/5 Interleaved
Number of wide elements (bars and gaps)
Number – 1 I Code = ----------------------------------------2
Calculated code length
EAN
Not applicable
13 characters (normal version) 8 characters (short version)
activate 13-digit activate 8-digit
UPC
Not applicable
12 characters (UPC A, normal version) 8 characters (UPC E, short version)
Activate Version A Activate Version E
Codabar
Number of bars
Number – 8 I Code = ----------------------------------------4
Calculated code length
Code 128 (character set A)
Number of bars
Number – 10 I Code = ---------------------------------------------3
Calculated code length
EAN 128
Number of bars
Number – 10 I Code = ---------------------------------------------3
Calculated code length
Code type
Count
Code 39
1) Check digit optional for Code 39, 2/5 Interleaved, Codabar. Check digit always integrated in the bar code print at EAN, UPC, Code 128, EAN 128 in accordance with specification (is suppressed automatically at the output of the read result of the CLP100) 2) With few exceptions each printed character corresponds to an ASCII character which has to be decoded. In the case of Code 39 extended, Code 128 and EAN 128 the number of characters in the data string of the CLP100 can exceed the number of characters in the printing image because it consists of several character sets.
Table 10-3: Auxiliary table for calculating the code length of a bar code
52
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 53
Operating Instructions
Appendix
Chapter 10
CLP100 Bar Code Reader
10.5
Command language for CLP100 bar code reader
Table 10-4 lists the commands of the command language for CLP100. The default settings of the respective parameters are printed in bold. For sending host commandos to the CLP100 it is nesessary to frame the data string with <ESC> and <CR>. Example: <ESC>U0B2<CR> (Meaning: enable lable no. 1, set to Codabar) There may be not any blank between the characters. Parameter
Character
Value
Number Of Codes
UAx x: 0: FREE 1-10: 1 - 10 Labels to be read with one Sensor
Output On Good Read
UBx x: 0: 1:
AFTER SENSOR AFTER READ
Label Number
Ux x: 0: ... 9:
Label Number 1 Label Number 10 CODE 39 Codabar ITF JAN (UPC) ITF-B CODE 128
Code Type
UxBy y: 1: 2: 3: 4: 5: 7:
Code Length
UxByNz z: 0: FREE 1-32: Specified Digits (1 - 32)
Reading Direction
UxByNzDa a: 0: 1: 2:
NOT SPECIFIED FORWARD REVERSE
Check Digits
UxByNzDaCb b: 0: 1: 3:
NO CHECK SEND C/D NOT SEND C/D
(Codabar Only)
UxByNzDaCb b: 0: 1: 2: 3: 4:
NO CHECK SEND M16 SEND 7DR NOT SEND M16 NOT SEND 7DR
Transmit Start/Stop
UxByNzDaCbSc c: 0: 1:
SEND NOT SEND
Option (Code 128)
UxB7NzDaEd d: 0: 1: 2:
NOT SEND SEND THROUGH SEND TRANSLATED
Transmit Leading Character
UxByNzDaCbScKe
Host Interface
UHx x: 0:
RS-232C
Baud Rate
UH0Fy y: 0: 1: 3: 4:
1,200 2,400 9,600 19,200 e: 0: NONE 2,“N“: N = 0 - 9 (30h - 39h) & Upper Character
Table 10-4: Command language for CLP bar code readers
8008912/R289/2008-11-28
© SICK AG · Division Auto Ident · Germany · All rights reserved
53
Page 54
Chapter 10
Appendix
Operating Instructions CLP100 Bar Code Reader
Parameter
Character
Value
Data/Parity/Stop Bits
UH0Py y: 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11:
7O1 7O2 7E1 7E2 8N1 8N2 8O1 8O2 8E1 8E2 7N1 7N2
Terminator
UH0Ty y: 0: 1: 2: 3: 4: 5:
NONE <SX>/<EX> /<CR><LF> /<CR> <SX>/<EX><CR> <EX>/<CR>
Cs Control
UH0Hy y: 0: 1:
NO CONTROL CONTROL
Error String
UH0Ry y: 0: 1: 2: 3: 4:
NOT SEND BR ? <CAN> ERROR
Result Output Time
UExx xx: 00: HOLD 1-99: 10 - 990 ms 10: 100 ms One Shot
Result Function
UJx x: 0: 1: 2:
DISABLED GOOD READ NO READ
Result Output Timing
UFx x: 0: 1:
AFTER READ AFTER SENSOR OFF
Memory
Mx x: 0: 1: 2:
DEFAULT RECALL N. V. MEMORY WRITE N. V. MEMORY
Multiple Reads
Xxx xx: 1-10: 1 - 10 Times 2: 2 Times
End Of Reading Interval
Yx x: 0: GENERATED BY TRIGGER 1,nn: 01 - 99 BY TIMER
Debouncing Sensor
UYx x: 0: 1: 2:
1 ms 5 ms 10 ms
Codabar Start/Stop Character
USx x: 0: 1:
LOWER CASE UPPER CASE
Separator
UTx x: 0: 1: 2: 3: 4: 5:
NONE & FS GS SP
Table 10-4: Command language for CLP bar code readers (contd.)
54
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 55
Operating Instructions
Appendix
Chapter 10
CLP100 Bar Code Reader
Parameter
Character
Value
LED Control
UIx x: 0: 1:
CCD ON (Red) & READING GATES ON (Green) NO READ (Red) & GOOD READ (Green)
Minimum Time Between Labels
UDx x: 0:
NOT READ nn: 01-99 = Prohibition Time 10-990 ms
Code Comparison
UNx x: 0: 1:
NO YES
Sensor Input
Ax x: 0:
LEVEL 0,mm: EDGE mm s (mm = 1 - 60 ms) OFF
1: Operation Mode
UCx x: 0: 1: 2: 3:
READING MODE DIAGNOSIS MODE ONLINE TESTING MODE ADJUSTMENT MODE
Result Output On Code Comparison
UQx x: 0: 1:
ACTIVE HIGH ON READ & MATCH ACTIVE HIGH ON READ & NO MATCH
Teach In Code Comparison
URx x: 0: 1:
NO YES
Read Out
Wx x: 0: 1: 4: 5:
VERSION INFORMATION SETUP OUTPUT BAUD RATE/FRAME (1 STOP) BAUD RATE/FRAME (2 STOP)
Table 10-4: Command language for CLP bar code readers (contd.)
Selection of a bar code (example): 2/5 ITF 6-digit without check digit Reqired command: <STX>U0B3N6D0C0<CR>
8008912/R289/2008-11-28
© SICK AG · Division Auto Ident · Germany · All rights reserved
55
Page 56
Chapter 10
Appendix
Operating Instructions CLP100 Bar Code Reader
10.6
EC Declaration of Conformity
10.6.1
Copy of the EC Declaration of Conformity
Fig. 10-3 shows a scaled down copy of the EC Declaration of conformity, page 1 for the CLP100 bar code reader. ¾
Fig. 10-3:
56
The complete EC Declaration of Conformity and the list of device versions and the standards met can be requested from SICK AG.
Copy of the EC Declaration of of conformity, page 1 (scaled down in size)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8008912/R289/2008-11-28
Page 57
Appendix
Operating Instructions
Chapter 10
CLP100 Bar Code Reader
Notes:
8008912/R289/2008-11-28
© SICK AG · Division Auto Ident · Germany · All rights reserved
57
Page 58
8008912/R289/2008-11-28 ∙ 5M/TR <PM6.5/FM7.0/PDF>/VD ∙ Printed in Germany ∙ Subject to change without notice ∙ The specified product features and technical data do not represent any guarantee ∙ 05 Aft int62
Australia Phone +61 3 9497 4100 1800 33 48 02 – tollfree E-Mail sales@sick.com.au Belgium/Luxembourg Phone +32 (0)2 466 55 66 E-Mail info@sick.be Brasil Phone +55 11 3215-4900 E-Mail sac@sick.com.br Ceská Republika Phone +420 2 57 91 18 50 E-Mail sick@sick.cz China Phone +852-2763 6966 E-Mail ghk@sick.com.hk Danmark Phone +45 45 82 64 00 E-Mail sick@sick.dk Deutschland Phone +49 211 5301-270 E-Mail info@sick.de España Phone +34 93 480 31 00 E-Mail info@sick.es France Phone +33 1 64 62 35 00 E-Mail info@sick.fr Great Britain Phone +44 (0)1727 831121 E-Mail info@sick.co.uk India Phone +91–22–4033 8333 E-Mail info@sick-india.com Israel Phone +972-4-999-0590 E-Mail info@sick-sensors.com Italia Phone +39 02 27 43 41 E-Mail info@sick.it
Österreich Phone +43 (0)22 36 62 28 8-0 E-Mail office@sick.at Polska Phone +48 22 837 40 50 E-Mail info@sick.pl Republic of Korea Phone +82-2 786 6321/4 E-Mail kang@sickkorea.net Republika Slowenija Phone +386 (0)1-47 69 990 E-Mail office@sick.si România Phone +40 356 171 120 E-Mail office@sick.ro Russia Phone +7 495 775 05 34 E-Mail info@sick-automation.ru Schweiz Phone +41 41 619 29 39 E-Mail contact@sick.ch Singapore Phone +65 6744 3732 E-Mail admin@sicksgp.com.sg Suomi Phone +358-9-25 15 800 E-Mail sick@sick.fi Sverige Phone +46 10 110 10 00 E-Mail info@sick.se Taiwan Phone +886 2 2375-6288 E-Mail sickgrc@ms6.hinet.net Türkiye Phone +90 216 587 74 00 E-Mail info@sick.com.tr USA/Canada/México Phone +1(952) 941-6780 1 800-325-7425 – tollfree E-Mail info@sickusa.com
Japan Phone +81 (0)3 3358 1341 E-Mail support@sick.jp Nederlands Phone +31 (0)30 229 25 44 E-Mail info@sick.nl Norge Phone +47 67 81 50 00 E-Mail austefjord@sick.no
SICK AG | Waldkirch | Germany | www.sick.com
More representatives and agencies in all major industrial nations at www.sick.com