Operating Instructions CLP100 Bar Code Reader: 9 Technical data

Pages 43 to 45 of 58, from Operating Instructions CLP100 Bar Code Reader

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLP100

Page 43

Operating Instructions

Technical data

Chapter 9

CLP100 Bar Code Reader

9

Technical data 9.1

Data sheet CLP100 bar code reader

Type

CLP100

Scanner design

CCD bar code reader

Light source

Visible red light (λ = 630 nm)

LED class

Class 1 according to EN 60825-1/A2 (2001-03) and IEC 60825-1 AMD2 (2001-01)

Artificial light compatability

0 to 100,000 lux

Scanning/Decoding frequency

500 Hz

Reading distance/Resolution

30 to 40 mm: (1.18 to 1.58 in 25 to 45 mm: (0.99 to 1.77 in 25 to 45 mm: (0.99 to 1.77 in 25 to 55 mm: (0.99 to 2.17 in 25 to 55 mm: (0.99 to 2.17 in 25 to 55 mm: (0.99 to 2.17 in

Reading area width

80 mm (3.15 in) (at a reading distance of 40 mm (1.58 in))

Minimum resolution

0.15 mm (5.9 mil)

0.15 mm 5.9 mil) 0.2 mm 7.9 mil) 0.25 mm 9.8 mil) 0.35 mm 13.8 mil) 0.5 mm 19.7 mil) 1 mm 39.5 mil)

Code types

All common bar codes

Number of codes per reading pulse

Max. 10 codes

Code length

Max. 32 digits (depends on number of codes per reading pulse)

Optical indicators

Status display with two LEDs (red and green)

Data interfaces

2 x (RS 232), parallel operation (transmitting/monitoring)

Data transfer rate

1,200 to 19,200 Bd

Digital switching input

Vin = max. 5 V, Iin ≤ 1,5 µA

Digital switching output

Iout = max. 50 mA

Electrical connection

Cable (0.9 m (2.95 ft)), with 9-pin D Sub plug or open end

Supply voltage

5 V DC ± 5 % according to IEC 60364-4-41

Power consumption (reading operation)

350 mA

Power consumption (standby mode)

150 mA

Housing

Metal

Enclosure rating

IP 40

EMC test

According to EN 61000-6-2 (2001-10-01), 61000-6-3 (2001-10-01), 61000-6-3/A11 (2004-07-01)

Weight

Approx. 200 g (7.05 oz)

Temperature (ambient service/storage)

0 to +40 °C / −20 to +70 °C (+32 to 104 °F/ −4 to +158 °F)

Maximum relative humdity

30 to 85 %, non-condensing

Table 9-1: Technical specification of the CLP100

8008912/R289/2008-11-28

© SICK AG · Division Auto Ident · Germany · All rights reserved

43

Page 44

Chapter 9

Technical data

Operating Instructions CLP100 Bar Code Reader

9.2

Reading field diagram

The reading area diagram shows the reading width as a ratio of the reading distance for various resolutions. Disturbing optical effects (distortions) which can occur when the distance is too great are taken into account when specifying the reading width.

Reading field height

The module width is the narrowest bar of a bar code which is still resolved. mm (in) (1.97) (1.58) (1.18) (0.79) (0.39)

(-0.39) (-0.79) (-1.18) (-1.58) (-1.97) mm (in) (0.39) (0.79) (1.18) (1.58) (1.97) (2.36) (2.76) Reading distance Resolution in mm (mil)

a: 0.15 (5.9 mil) b: 0.2 (7.9 mil), 0.25 (9.8 mil) c: 0.35 (13.8 mil), 0.5 (19.7 mil), 1.0 (39.5 mil)

Reading Conditions:

Fig. 9-1:

44

Test Code: Print Ratio: Print Contrast: Pitch/Tilt

39 3:1 90 % 0°

Reading field diagram

© SICK AG · Division Auto Ident · Germany · All rights reserved

8008912/R289/2008-11-28

Page 45

Operating Instructions

Technical data

Chapter 9

CLP100 Bar Code Reader

9.3

Dimensional drawings

*) Screws may not project more than 2.5 mm (0.1 in) into the CLP100 All dimensions in mm Fig. 9-2:

Dimensions of the CLP100 with front end reading window

*) Screws may not project more than 2.5 mm (0.1 in) into the CLP100

All dimensions in mm

Fig. 9-3:

Dimensions of the CLP100 with side reading window mm inch mm inch mm inch mm inch

3

0.12

7

0.28

15

0.59

24

0.95

4.5

0.18

10

0.39

16.5

0.65

47

1.85

5

0.20

11

0.43

20

0.79

55

2.17

Table 9-2: Conversion table for dimensions in the figures above (mm to inch)

8008912/R289/2008-11-28

© SICK AG · Division Auto Ident · Germany · All rights reserved

45