Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 10

Operating Instructions CLP100 Bar Code Reader: 7 Maintenance

Pages 37 to 39 of 58, from Operating Instructions CLP100 Bar Code Reader

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLP100

Page 37

Operating Instructions

Maintenance

Chapter 7

CLP100 Bar Code Reader

7

Maintenance 7.1

Maintennance during operation

The CLP100 operates maintenance free. No maintenance is required to keep this product in compliance with LED class 1.

NOTICE Claims under the warranty rendered void! Do not open the housing of the CLP100. If the device is opened, the SICK AG warranty shall not apply.

7.2 Recommendation

Cleaning the CLP100

In order to make use of the full optical reading capacity of the CLP100, the reading window should be checked regulary (e.g. weekly) for soiling. This is especially recommended when operating the device in harsh conditions (dust, abraison, humidity).

CAUTION LED radiation! The illumination of the CLP100 operates with LEDs of LED class 1. Under normal and sensible conditions, the accessible radiation of the LEDs is not hazardous. The entire area of the reading window acts as a LED outlet aperture. Caution – use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. ¾

Never look directly into the illumination.

¾

Do not open the housing. (Opening the housing does not deactivate the LEDs by the reading pulse.)

¾

Always observe the latest valid version of laser protection regulations.

7.2.1

Cleaning the reading window

NOTICE Damage to the reading window! The CLP100 reading window is made of glass. Scratches and streaks on the reading window impair the reading performance.

Important

8008912/R289/2008-11-28

¾

Use a mild detergent without scouring agents.

¾

Avoid cloths or sponges which scratch.

¾

Clean the reading window carefully.

Electrostatic charges cause dust particles to stick to the reading window. This effect can be combated by using anit-static SICK synthetic cleaner (no. 5600006) in combination with a SICK lens cloth (no. 4003353).

© SICK AG · Division Auto Ident · Germany · All rights reserved

37

Page 38

Chapter 7

Maintenance

Operating Instructions CLP100 Bar Code Reader

Cleaning the reading window: ¾

Use a clean, soft brush to free the reading window.

¾

If necessary, additionally clean the reading window with a clean, damp, lint-free cloth and a mild, anti-static window cleaning fluid.

a

Fig. 7-1:

b

Cleaning the reading window

If the reading window is scratched or damaged (cracked, broken), it must be replaced. Please contact the SICK Service. 7.2.2 ¾

Cleaning the housing

If necessary, also clean the LEDs on the back side of the housing.

7.2.3

Cleaning further optical effective surfaces

If an external reading pulse generator with a sensor (e.g. photoelectric reflex switch) is used, make sure to clean the relevant optical surfaces regulary (e.g. weekly). Contamination on these surfaces can cause switching errors. ¾

In oder to prevent incorrect switching behaviour, remove soiling from the optical effective surfaces of the external sensor.

7.3

Replacing a CLP100

An incorrect or damaged CLP100 has to be removed and replaced with either a new or an repaired CLP100.

NOTICE Repairs to the CLP100 should only be carried out by qualified and authorised SICK AG service staff.

7.3.1

38

Removing the CLP100

1.

Switch off the power supply to the CLP100.

2.

Remove the cable plug of the CLP100 respectively remove the wires when using the variant with open cable end.

3.

Mark the situation and alignment of the CLP100 on the holder or environment.

4.

Remove the CLP100 from the holder.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8008912/R289/2008-11-28

Page 39

Operating Instructions

Maintenance

Chapter 7

CLP100 Bar Code Reader

7.3.2

Replacing the CLP100

1.

Align and install the new or repaired CLP100. To do so, observe any marks made previously on the holder or environment (see also Chapter 4.4 Installation and adjustment of the device, Page 21).

2.

Reconnect the cable plug of the CLP100 respectively reconnect the wires when using the variant with open cable end.

3.

Switch on the power supply to the CLP100. The CLP100 starts with the factory default settings.

4.

Establish communication to the CLP100 using the CLP Setup configuration software.

5.

Transfer the configuration of the replaced device stored on the PC via download to the new CLP100 (see Chapter 6.4.1 Transferring the parameter set between the CLP Setup and CLP100, Page 31). The configuration can only be transferred between identical device types.

6.

Check the behaviour of the CLP100 in the reading process.

7.4

Disposal

After removal from service dispose of unusable or irreparable devices in a manner which is not harmful to the environment. Observe the respective state regulations on waste disposal. At present, SICK AG does not take back devices which have become unusable or irreparable.

8008912/R289/2008-11-28

1.

Remove the CLP100 housing.

2.

Remove the electronic modules and connection cable.

3.

Recycle the housing.

4.

Dispose of electronic modules and connection cable as hazardous waste.

© SICK AG · Division Auto Ident · Germany · All rights reserved