Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Quadrus MINI Imager User's Manual

Manual · Microscan

Quadrus MINI Imager User's Manual

Manual424 pagesPDF 3.7 MB

User's manual for the Microscan Quadrus MINI imager: setup, ESP software, communications, calibration and symbology settings.

Download the PDF3.7 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

The complete user's manual for the Microscan Quadrus MINI Imager, a fixed-mount imager that reads linear and 2D symbols. It walks through a quick start with the EZ Button or ESP (Easy Setup Program), then covers communications, calibration, read cycle, symbologies, I/O parameters, symbol quality, matchcode, camera and IP setup, the configuration database, terminal, utilities and output format, with serial commands for each setting.

Its parts

  1. Quick Start
  2. Using ESP
  3. Communications
  4. Calibration
  5. Read Cycle
  6. Symbologies
  7. I/O Parameters
  8. Symbol Quality
  9. Matchcode
  10. Camera and IP Setup
  11. Configuration Database
  12. Terminal
  13. Utilities
  14. Output Format

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

The Microscan user's manual for the Quadrus MINI Imager and Quadrus MINI ESD Safe (as printed), megapixel (SXGA) imagers with software-adjusted focus. The site files it under the MINI 3, which the manual does not describe. It covers quick-start setup with the EZ Button or ESP software, calibration, read rate tests, and the general and electrical specifications.

Read for this summary: pages 1 to 2, 8 to 11, 13 to 26, 364 to 369 and 388 to 389 of 424.

Device
Quadrus MINI megapixel (SXGA) imager for linear and 2D symbologies, with software-adjustable focus p. 8
Interfaces
RS-232/422/485 or USB models p. 366
Connector
3 ft. cable with a High Density 15-pin D-Sub socket connector or USB type A connector p. 364
Power
5VDC +/– 5%, 200 mV p-p max. ripple, 554 mA @ 5VDC (typ.), 4.0 Watts (max.) p. 367
Resolution
SXGA: 1280 by 1024 pixels, progressive scan, electronic shutter p. 364
Read parameters
Focal range 2 to 6" (50.8 to 152.4 mm), autofocus; up to 10 decodes per second; pitch ±30°, skew ±30°, tilt 360° p. 364
Symbologies
Data Matrix (ECC 0-200), Aztec Code, QR Code, Micro QR Code, PDF417, MicroPDF417, GS1 DataBar, Code 39, Code 128, BC412, Interleaved 2 of 5, Pharmacode, UPC/EAN, Codabar, Code 93, Postal p. 364
Size and weight
Height 1" (25.4 mm), width 1.8" (45.7 mm), depth 2.10" (53.3 mm); 2 oz. (57 g) p. 364
Environment
IP54 enclosure; operating 0° to 40°C (32° to 104°F); storage -50° to 75° C; humidity up to 90% (non-condensing) p. 364
Discrete I/O
Trigger and New Master inputs 5 to 28VDC (0.16 mA); outputs 1, 2, 3 5V TTL, sink and source 10 mA; optoisolated with IC-332 accessory p. 364
Versions
Standard, High or Ultra-High Density; Q-Mode; ESD Safe with a nickel-plated case p. 366, 368
Quick-start hardware
IC-332 Adapter, IB-131 Interface Box, power supply (90-264 VAC, 24VDC), object detector, communication cable p. 14
ESP software needs
Windows Vista, XP, or 2000; Internet Explorer 5.0 or higher; 64 MB RAM; 40 MB disk; 800 x 600, 256 colors p. 17
Indicators
Read performance, power and read status LEDs; green flash on good read; blue target pattern; beeper p. 364

What this manual walks you through

  • Checking the hardware needed for a first setup p. 14
  • Connecting by RS-232/RS-422/RS-485 or USB p. 15
  • Positioning the imager and symbol p. 16
  • Installing the ESP setup program p. 17
  • Selecting the model and connection protocol in ESP p. 18, 19, 20
  • Locating the symbol with the blue target pattern p. 21, 22
  • Calibrating by EZ Button, ESP or serial command p. 23
  • Testing the read rate p. 24
  • Configuring and saving settings in ESP p. 25, 26
  • Triggering reads with an object detector p. 388

Good to know

  • Connect all cables before applying power, and power down before disconnecting any cable. p. 14
  • A USB model must be connected to the host before power-on, or it is not recognized as a USB device. p. 15
  • Clean the hard-coated window only with 100% isopropyl alcohol. p. 389
  • Do not insulate the stand mount: the bottom panel needs metal-to-metal contact to shed heat. p. 389
  • Maximum skew and pitch are each ±30°. p. 16

Questions this manual answers

How do I calibrate a Quadrus MINI with the EZ Button?

Hold the EZ Button about two seconds until two short beeps, then release; the imager searches camera settings for the best configuration. p. 23

What do 5 short beeps from the Quadrus MINI mean?

Calibration was unsuccessful and the imager stopped searching camera settings. p. 23

Why is my USB Quadrus MINI not recognized by the computer?

A USB model must be connected to the host computer before it is powered on. p. 15

How do I restore the Quadrus MINI default configuration?

Connect pin 8 to ground pin 4 on the 15-pin host connector. p. 367

What power does the Quadrus MINI imager need?

5VDC +/– 5% with at most 200 mV ripple; it draws 554 mA typical and 4.0 Watts maximum. p. 367

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Quadrus MINI Imager User’s Manual1
    1. About the Quadrus MINI Imager8
    2. About This Manual8
    3. Highlighting8
    4. Host Communications8
    5. Warning and Caution Summary9
    6. Statement of Agency Compliance10
    7. Statement of RoHS Compliance11
    8. 1 Quick Start13
    9. 2 Using ESP27
    10. 3 Communications45
    11. 4 Calibration79
    12. 5 Read Cycle99
    13. 6 Symbologies129
    14. 7 I/O Parameters181
    15. 8 Symbol Quality239
    16. 9 Matchcode255
    17. 10 Camera and IP Setup267
    18. 11 Configuration Database299
    19. 12 Terminal319
    20. 13 Utilities325
    21. 14 Output Format349
    22. Appendices363
    23. Index399

From the PDF’s own bookmarks.

The whole text · 43 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 130121-130
  14. Pages 131 to 140131-140
  15. Pages 141 to 150141-150
  16. Pages 151 to 160151-160
  17. Pages 161 to 170161-170
  18. Pages 171 to 180171-180
  19. Pages 181 to 190181-190
  20. Pages 191 to 200191-200
  21. Pages 201 to 210201-210
  22. Pages 211 to 220211-220
  23. Pages 221 to 230221-230
  24. Pages 231 to 240231-240
  25. Pages 241 to 250241-250
  26. Pages 251 to 260251-260
  27. Pages 261 to 270261-270
  28. Pages 271 to 280271-280
  29. Pages 281 to 290281-290
  30. Pages 291 to 300291-300
  31. Pages 301 to 310301-310
  32. Pages 311 to 320311-320
  33. Pages 321 to 330321-330
  34. Pages 331 to 340331-340
  35. Pages 341 to 350341-350
  36. Pages 351 to 360351-360
  37. Pages 361 to 370361-370
  38. Pages 371 to 380371-380
  39. Pages 381 to 390381-390
  40. Pages 391 to 400391-400
  41. Pages 401 to 410401-410
  42. Pages 411 to 420411-420
  43. Pages 421 to 424421-424

The file

Revision and size

RevisionP/N 83-006300 Rev F, 2010
PublisherMicroscan Systems, Inc.
Pages424
PDF3.7 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 424

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 424
Page 2
Page 2of 424
Page 3
Page 3of 424

More documents · 1

For the same models