Page 311
Configuration Database
Image Dimensions Definition: Serial Cmd: Default: Options:
Determines how the image dimension parameters will be implemented. <K256,switch mode,frame count/time,image process looping,image dimensions> 0 0 = Window of Interest 1 = Region of Interest
Window of Interest (WOI) by ESP When Image Dimensions is set to Window of Interest, the database image dimension parameters are camera settings, and they determine the size of the image to be captured.
Camera settings (Capture Index, Shutter Speed, Gain, Focal Distance, Sub-Sampling) located in the left half of the highlighted area. Image capture dimensions (Row Pointer, Column Pointer, Row Depth, Column Width) located in the right half of the highlighted area.
Quadrus MINI Imager User’s Manual
11-13
Page 312
Database Mode
Region of Interest (ROI) When Image Dimensions is set to Region of Interest, the database image dimension parameters are IP and decode settings, and they determine the region or area of the captured image to be processed. ROI coordinate data is based on the full image size. The WOI of the captured image will be configured to cover all the ROI settings in the current, active database entry. In the following example, there are three active database settings, each with a different ROI configuration. Their coordinates are based at point 0,0 of the full scale image (1280 x 1024). In this example, DB1 and DB3 determine the size of the captured image WOI, while DB2 has no impact. The image WOI is not configurable. It is automatically set up by the database according to the ROI settings. row pointer column pointer
DB 1 IP ROI row size
DB 2 IP ROI column size
DB 3 Camera WOI
IP ROI
Full Image Size (1280 x 1024) Note: Since the ROI parameters are not a camera setting, a change in ROI parameters from one index to another does not indicate an image capture event. This feature is intended to be used in conjunction with Image Process Looping, to allow different regions of a captured image to be processed using different IP and decode settings. Also, if this feature is used in conjunction with Output Filtering, multiple decoded symbols in a captured image frame can be output according to their location in the field of view. 11-14
Quadrus MINI Imager User’s Manual
Page 313
Configuration Database
Region of Interest (ROI) by ESP When Image Dimensions is set to Region of Interest, the database image dimension parameters are IP and decode settings, and they determine the region or area of the captured image to be processed.
Threshold Mode, Fixed Threshold Value, Processing Mode, Narrow Margins, Background, and Code Type are all Processing Settings values.
Quadrus MINI Imager User’s Manual
11-15
Page 314
Save Current Settings to Configuration Database
Save Current Settings to Configuration Database Definition: Serial Cmd:
Allows current, active configuration settings to be saved to a selected database index. <K255+,index>
Example: <K255+,5> This command phrase saves the imager’s current, active configuration settings to database index 5.
Save Current Settings to Configuration Database by ESP
Click the Load Current to Index button to save the imager’s current configuration parameters to the selected database index.
11-16
Quadrus MINI Imager User’s Manual
Page 315
Configuration Database
Load Current Settings from Configuration Database Definition: Serial Cmd:
Allows the configuration settings contained in a selected database index to be loaded to current, active configuration settings. <K255-,index>
Example: <K255-,5> This command phrase loads the configuration settings contained in database index 5 to current, active configuration settings.
Load Current Settings from Configuration Database by ESP
Click the Load Index to Current button to load configuration settings from the selected index to current, active settings.
Notes on Symbol Type • The current DataBar Expanded status does not change if it is configured as Enabled (Stacked) and the database DataBar Expanded status is Enabled. • The current DataBar-14 status does not change if it is configured as Enabled (Stacked) and the database DataBar Expanded status is Enabled. • Data Matrix ECC level is determined by the current settings and not by database settings. Therefore, the database does not know which ECC level to enable, and has no effect on current Data Matrix ECC settings.
Quadrus MINI Imager User’s Manual
11-17
Page 316
Request Selected Index Settings
Request Selected Index Settings Definition: Serial Cmd:
Returns configuration settings for the selected database index. <K255?,index>
Example: <K255?,5> This command phrase returns the configuration settings for database index 5.
11-18
Quadrus MINI Imager User’s Manual
Page 317
Configuration Database
Request All Configuration Database Settings Definition: Serial Cmd:
Returns configuration settings for all indexes in the configuration database. <K255?>
Example: <K255?> This command phrase returns the configuration settings for all 10 database indexes.
Quadrus MINI Imager User’s Manual
11-19
Page 318
Request All Configuration Database Settings
11-20
Quadrus MINI Imager User’s Manual
Page 319
12 Terminal Contents Terminal Window........................................................................................................................ 12-2 Find ............................................................................................................................................ 12-3 Send ........................................................................................................................................... 12-4 Macros........................................................................................................................................ 12-5 Terminal Window Menus............................................................................................................ 12-6
This section describes the Terminal window and macro functions in ESP.
Quadrus MINI Imager User’s Manual
12-1
Page 320
Terminal Window
Terminal Window Click this button to display the Terminal view. The following view will appear: Copy, paste, save
Clear screen
Type text here to find matching text in the Terminal window.
Terminal screen
Macros listed on this bar
Type serial commands here.
Click on desired Macro to run. Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro.
The Terminal screen allows you to send serial commands to the imager by using Macros, by copying and pasting, or by typing commands in the Send text field. The Terminal screen also displays symbol data or information from the imager. You can also right-click on the Terminal screen to bring up a menu of further options.
12-2
Quadrus MINI Imager User’s Manual