Page 301

Configuration Database

Number of Active Indexes Usage:

Definition:

Serial Cmd: Default: Options:

Useful for applications that require several different complex imager configurations to be applied sequentially. Multiple database indexes allow you to concatenate configuration profiles, and to perform more complex operations than would be possible with only one set of configuration parameters. This feature allows you to set the number of database records (groups of settings) that will be used automatically during the read cycle. If Number of Active Indexes is set to 0, only the current imager settings will be used, not database entry settings. <K252,number of active indexes,database sort> 0 (disabled) 0 to 10

Database Sort Definition: Serial Cmd: Default: Options:

Database Sort moves the database entry that produced a successful decode to the first position in the list of database entries. <K252,number of active indexes,database sort> Disabled 0 = Disabled 1 = Enabled

Number of Active Indexes by ESP Click the arrow on the Active Indexes dropdown menu and select how many database indexes will be used during the read cycle. (0 to 10).

Sort Index Positions on Good Reads moves the database entry that produces the first successful decode to the top of the list.

Quadrus MINI Imager User’s Manual

11-3

Page 302

Configuration Database Status

Configuration Database Status Index Usage:

Useful for applications that require several different complex imager configurations to be applied sequentially. Multiple database indexes allow you to concatenate configuration profiles, and to perform more complex operations than would be possible with only one set of configuration parameters. Definition: Determines the specific database index that will be used. Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology type> Options: 1 to 10

Shutter Speed Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology type> Default: 250 Options: 15 to 15,000

Gain Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology type> Default: 20 Options: 0 to 48

Focal Distance Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology type> Default: 400 (4”) Options: 200 to 600

11-4

Quadrus MINI Imager User’s Manual

Page 303

Configuration Database

Pixel Sub-Sampling Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology type> Default: Disabled Options: 0 = Disabled 1 = 4:1 2 = 16:1 Important: Sub-sampling has no effect when the Image Dimension mode is configured as Region of Interest in the Database Mode command. This is because the Window of Interest camera settings are determined by the software based on the Region of Interest setup. There is no benefit to sub-sampling to increase processing speed when ROI is configured, because the frame size would need to be increased to make sub-sampling possible.

Row Pointer Definition:

The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology type> Default: 0 Options: 0 to (1024-row depth)

Column Pointer Definition:

The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology type> Default 0 Options: 0 to (1280-column width)

Quadrus MINI Imager User’s Manual

11-5

Page 304

Configuration Database Status

Row Depth Definition:

The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel binning,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology> Default: 480 Options: 3 to (480 – row pointer)

Column Width Definition:

The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel binning,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology> Default 752 Options: 8 to (752 – column pointer)

Threshold Mode Note: Threshold Mode is not supported when Q-Mode is enabled. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel binning,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology> Default: Adaptive Options: 0 = Adaptive 1 = Fixed

Fixed Threshold Value Note: Fixed Threshold Value is not supported when Q-Mode is enabled. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel binning,row pointer, column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology> Default: 128 Options: 0 to 255

11-6

Quadrus MINI Imager User’s Manual

Page 305

Configuration Database

Processing Mode Important: Options 2 and 3 are not available in non-Q-Mode imagers. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel binning,row pointer, column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology> Default: Both Options: 0 = Standard 1 = Fast Linear Mode 2 = Q-Mode 3 = Both Note: The following items are not supported when Q-Mode is enabled: • Hollow Mode • Number of Symbols in Field of View • Damaged Symbol • IP Threshold • BC412 Symbology • 2D Enhanced (Narrow Margins) • Large Intercharacter Gap (Code 39) • Large Intercharacter Gap (Codabar) • Guard Bar Status (Interleaved 2 of 5) • Codeword Collection (PDF417) • Print Growth (ISO/IEC 16022 Symbol Quality Output) • Axial Non-Uniformity (Data Matrix Only) (ISO/IEC 16022 Symbol Quality Output) • Unused Error Correction (Data Matrix Only) (ISO/IEC 16022 Symbol Quality Output) • Percent Cell Damage (Data Matrix Only) (Microscan Symbol Quality Output) • Pixels Per Element (Data Matrix Only) (Microscan Symbol Quality Output) • Error Correction Level (Data Matrix Only) (Microscan Symbol Quality Output) • Matrix Size (Data Matrix Only) (Microscan Symbol Quality Output) • Detailed No Read Message (No Read Message) • Bad Symbol Message • No Symbol Message • 1D/Stacked Symbology Qualification • 2D Symbology Qualification

Narrow Margins Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel binning,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology> Default: 2D Enhanced Options: 0 = Disabled 1 = Enabled 2 = 2D Enhanced

Quadrus MINI Imager User’s Manual

11-7

Page 306

Configuration Database Status

Background Color Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel binning,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode,narrow margins,background color,symbology> Default: Both Options: 0 = White 1 = Black 2 = Both

Symbology Definition:

This field allows the user to configure the database to enable specific symbologies for selected database indexes. Symbology-specific parameters must be configured with the appropriate symbology command. For example, if fixed length Code 128 is required, it must first be set up with the Code 128 command: <K474>. To select a particular symbology, add the number value associated with that symbology type. Examples: If Data Matrix and Code 39 are required, the paramater would be: 2 + 16 = 18.

If I 2/5, BC412, and DataBar Limited (RSS Limited) are required, the parameter would be: 128 + 2048 + 16384 = 18560. Serial Cmd: <K255,index,shutter speed,gain,pixel binning,row pointer,column pointer,row depth,column width,threshold mode,fixed threshold value,processing mode, narrow margins,background color,symbology> Default: Disabled

Disabled When Symbology Type is disabled, the database uses the current Symbology Type setup to determine active symbologies.

Any Symbology (Add 1) All symbologies except Pharmacode are enabled while this database index is being used.

Data Matrix (Add 2) If enabled, Data Matrix will be active for this database index. Important: The ECC level must be configured using the Data Matrix command <K479>. If no ECC level has been configured, the imager will not decode Data Matrix symbols.

QR Code (Add 4) If enabled, QR Code will be active for this database index.

Code 128 (Add 8) If enabled, Code 128 will be active for this database index. 11-8

Quadrus MINI Imager User’s Manual

Page 307

Configuration Database

Code 39 (Add 16) If enabled, Code 39 will be active for this database index.

Codabar (Add 32) If enabled, Codabar will be active for this database index.

Code 93 (Add 64) If enabled, Code 93 will be active for this database index.

Interleaved 2 of 5 (Add 128) If enabled, Interleaved 2 of 5 will be active for this database index.

UPC/EAN (Add 256) If enabled, UPC/EAN will be active for this database index.

PDF417 (Add 512) If enabled, PDF417 will be active for this database index.

MicroPDF417 (Add 1024) If enabled, MicroPDF417 will be active for this database index.

BC412 (Add 2048) If enabled, BC412 will be active for this database index. Note: BC412 is not supported when Q-Mode is enabled.

Pharmacode (Add 4096) If enabled, Pharmacode will be active for this database index.

DataBar-14 (RSS-14) (Add 8192) If enabled, DataBar-14 will be active for this database index. Important: If the stacked and non-stacked operation is required, the DataBar-14 command must be configured as follows: <K482,2>. If the DataBar-14 status parameter in the <K482> command is set to either DISABLED or ENABLED, the imager will only read non-stacked DataBar-14 symbols.

DataBar Limited (RSS Limited) (Add 16384) If enabled, DataBar Limited will be active for this database index.

DataBar Expanded (RSS Expanded) (Add 32768) If enabled, DataBar Expanded will be active for this database index. Important: If the stacked and non-stacked operation is required, the DataBar Expanded command must be configured as follows: <K484,2>. If the DataBar Expanded status parameter in the <K484> command is set to either DISABLED or ENABLED, the imager will only read non-stacked DataBar Expanded symbols. Quadrus MINI Imager User’s Manual

11-9

Page 308

Configuration Database Status

Micro QR Code (Add 65536) If enabled, Micro QR Code will be active for this database index. Note: Micro QR Code is only supported when Q-Mode is enabled.

Aztec Code (Add 131072) If enabled, Aztec Code will be active for this database index. Note: Aztec Code is only supported when Q-Mode is enabled.

Postal Symbologies (Add 262144) If enabled, Postal Symbologies will be active for this database index. Note: Postal Symbologies are only supported when Q-Mode is enabled.

OCR (Add 524288) If enabled, OCR will be active for this database index.

11-10

Quadrus MINI Imager User’s Manual

Page 309

Configuration Database

Database Mode Switch Mode Definition:

Selects the event that causes the imager to load the next database entry to current, active settings. When Frame Count/Time expires and Image Process Looping is enabled, the next database entry with modifications to camera settings will be used. Note: The image capture event always occurs when the first database entry is used. Note: The Switch Mode setting has no effect on Rapid Capture Mode, which always operates in Number of Image Frames mode with a frame count of 1. Serial Cmd: <K256,switch mode,frame count/time,image process looping,image dimensions> Default: 1 Options: 0 = Time 1 = Number of Image Frames

Time When Switch Mode is set to Time, the imager will load the next database entry to current, active settings after a predefined time interval. The timer will start upon use of a database entry. If the timer expires during an image capture event, the timer will not start again until that database entry has been incremented and the new database entry has been loaded to current, active settings.

Number of Image Frames When Switch Mode is set to Number of Image Frames, the database entry is incremented after the predetermined number of image capture events has occurred.

Frame Count/Time Definition:

Indicates the Number of Image Frames that must be captured or the amount of Time that must transpire before the imager will load the next database index entry. Serial Cmd: <K256,switch mode,frame count/time,image process looping,image dimensions> Default: 1 (frames/ms) Options: 1 to 65535

Quadrus MINI Imager User’s Manual

11-11

Page 310

Database Mode

Image Process Looping Usage:

Useful in applications where it is necessary to process a single captured image multiple times using different IP and decode parameters. Serial Cmd: <K256,switch mode,frame count/time,image process looping,image dimensions> Default: Disabled Options: 0 = Disabled 1 = Enabled

Disabled When Image Process Looping is set to Disabled, an image is captured for every database configuration, whether or not any camera settings have been modified.

Enabled When Image Process Looping is set to Enabled, the last captured image frame is reprocessed with the new IP and decode parameters. If camera settings have not been changed from the last capture event, and when a database configuration is loaded to current, active settings, no new image is captured. Note: An exception to this is the first database index: a new image is always captured when the first database index is used. When a camera setting has been modified from one database setting to the next, a new image is captured. For example, if all database entries contained the same camera setting values but had different IP and decode parameters, an image frame would only be captured when the first database configuration was used.

11-12