Page 281
Camera and IP Setup
Pixel Sub-Sampling Definition: Usage: Default: Options:
The camera can be enabled to sub-sample pixels in the specified image frame. Sub-sampling can be set to either 4:1 or 16:1. These ratios signify the sampling rate. <K542,sub-sampling> Disabled 0 = Disabled 1 = 4:1 2 = 16:1
4:1 At this sampling rate, 1 pixel is output for every 4 pixels sampled. The image will be sampled 2:1 vertically and 2:1 horizontally, for a combined 4:1 ratio. An image with dimensions of 640 x 480 will be scaled to 320 x 240.
16:1 At this sampling rate, 1 pixel is output for every 16 pixels sampled. The image will be sampled 4:1 vertically and 4:1 horizontally, for a combined 16:1 ratio. An image with dimensions of 640 x 480 will be scaled to 160 x 120.
Quadrus MINI Imager User’s Manual
10-15
Page 282
Camera Settings
Camera Settings Camera parameters are typically obtained during the calibration process, and do not necessarily need to be modified directly by the user.
Optics The Quadrus MINI Imager has three different optical configurations available: Standard Density, High Density, and Ultra High Density. Determine the optics of your imager and find the corresponding camera values in the following sections.
Standard Density, High Density, and Ultra High Density Optics Shutter Speed Usage:
Definition:
Serial Cmd: Default: Options:
Faster shutter speeds reduce blurring in faster applications. Slower shutter speeds are useful in slower applications and lower contrast applications. This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If a slow shutter speed is selected to capture fast-moving objects, blurring or smearing of the image will occur. As shutter speed is increased, more light and gain become necessary, because the pixels’ exposure time has decreased. <K541,shutter speed,gain> 250 (SD) 30 (HD) 300 (UHD) 15 to 15,000
Gain Usage: Definition:
Serial Cmd: Default: Options:
10-16
Can be used to adjust the brightness of the image. Sets the gain value for the image sensor. This setting can be configured through calibration, which is the recommended method. A higher gain value will increase the brightness of the image, but the visual noise reduction performance of the system is reduced. Before configuring gain settings, the desired shutter speed should already be set and the gain should be configured to optimize the shutter speed setting. <K541,shutter speed,gain> 20 0 to 48
Quadrus MINI Imager User’s Manual
Page 283
Camera and IP Setup
Focal Distance Definition:
Serial Cmd: Default:
Options:
This setting provides a means for configuring the focal distance of the imager. The input value is in terms of inches and is divided by 100 internally. For example, 400 sets the imager to a focal distance of 4 inches. It is important to note that the imager may not have an exact match for the focal position requested. The imager has a range of steps that are calibrated and mapped to focal positions. This input value is matched to the closest focal position step that the system supports. It is also important to keep in mind that the resolution of the system is not linear. As the imager’s focal distance setting increases, the resolution decreases. This effect is offset somewhat by the fact that the depth of field increases at greater focal distances. <K525,focal distance> Standard Density = 400 (4”) High Density = 400 (4”) Ultra High Density = 300 (3”) 200 (2”) to 600 (6”)
Note: In the factory, the imager calibrates its focus curve and matches the focus motor steps to various focal positions. Therefore, each imager has a slightly different focus map of stepper motor positions vs. focal positions. This allows the user to enter a focal distance that causes the imager to select the closest stepper motor position required to obtain the user-defined setting. In this way, there is consistency between imagers for any given focal distance input. Note: To view a list of focal distances supported by your imager, use the <K526> command.
Quadrus MINI Imager User’s Manual
10-17
Page 284
Focal Distance Table (Read-Only)
Focal Distance Table (Read-Only) Number of Focal Distances Definition: Serial Cmd: Options:
Specifies the number of focal distances supported by the imager. <K526,number of focal distances,focal distance> 1 to 255
Focal Distance Definition:
Serial Cmd: Options:
10-18
Each (x) output represents a focal distance that is supported by the imager. The values are specified in 1/100ths of an inch, but the focal distance increments and decrements are not that fine. The focal distance is defined from a curve equation whose constants are calibrated during factory setup. The output value is in terms of inches, and it is multiplied by 100 to remove the decimal place. For example, an output of 375 would signify a focal distance of 3.75”. <K526,number of focal distances,focal distance> 200 (2”) to 600 (6”)
Quadrus MINI Imager User’s Manual
Page 285
Camera and IP Setup
Increment Focus Position Definition:
Serial Cmd: Options:
Increments the imager’s focus setting to the next focal distance supported by the imager. Note: Use the Focus Distance Table command <K526> to find the focal distance settings supported by your imager. <K525+> 200 (2”) to 600 (6”)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <K525+> Send: <K525?> Response: <K525,447>
Decrement Focus Position Definition:
Serial Cmd: Options:
Decrements the imager’s focus setting to the next focal distance supported by the imager. Note: Use the Focus Distance Table command <K526> to find the focal distance settings supported by your imager. <K525-> 200 (2”) to 600 (6”)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <K525-> Send: <K525?> Response: <K525,264>
Quadrus MINI Imager User’s Manual
10-19
Page 286
IP Threshold
IP Threshold Note: IP Threshold is not supported when Q-Mode is enabled.
Threshold Mode Usage:
Definition:
Serial Cmd: Default: Options:
Fixed Mode works best when decode time must be as short as possible and the reflectance and illumination of the symbol area is uniform and unchanging. Cycle Fixed Mode is useful in applications where decode time can be slightly longer, and reflectance and illumination of the symbol area is uniform and unchanging. Otherwise, Adaptive Mode is the preferred mode. This value switches the image processing threshold mode between the Adaptive, Fixed, and Cycle Fixed modes. An adaptive routine sets the light/dark threshold using data acquired from the current read. A fixed routine applies the same gray scale threshold value to each and every symbol. A cycle fixed routine loops through a pre-defined range of values (Cycle Min to Cycle Max) by pre-defined increments (Cycle Step). <K512,threshold mode,fixed threshold value,cycle min,cycle max,cycle step,adaptive contrast percent> Adaptive 0 = Adaptive 1 = Fixed 2 = Cycle Fixed
Fixed Threshold Value Usage: Definition:
Serial Cmd: Default: Options:
A higher value will increase the threshold for distinguishing between light and dark elements. Determines how the imager will distinguish light pixels from dark pixels. This value is used for Fixed Mode only. When Adaptive Mode is set, this value is ignored. <K512,threshold mode,fixed threshold value,cycle min,cycle max,cycle step,adaptive contrast percent> 128 0 to 255
Cycle Min Definition: Starting value of the cycle mode. Serial Cmd: <K512,threshold mode,fixed threshold value,cycle min,cycle max,cycle step,adaptive contrast percent> Default: 0 Options: 0 to 255 Important: Cycle Min must be a smaller numerical value than Cycle Max.
10-20
Quadrus MINI Imager User’s Manual
Page 287
Camera and IP Setup
Cycle Max Definition: Ending value of the cycle mode. Serial Cmd: <K512,threshold mode,fixed threshold value,cycle min,cycle max,cycle step,adaptive contrast percent> Default: 255 Options: 0 to 255 Important: Cycle Max must be a greater numerical value than Cycle Min.
Cycle Step Definition: Serial Cmd: Default: Options:
The numerical value of a single cycle mode increment. <K512,threshold mode,fixed threshold value,cycle min,cycle max,cycle step,adaptive contrast percent> 10 0 to 255
Adaptive Contrast Percent Definition:
Serial Cmd: Default: Options:
The percentage value that sets the adaptive threshold map. Useful for underprinted or overprinted symbols. For example, if a value of 110 is entered, the adaptive threshold will be 110% of the original values. <K512,threshold mode,fixed threshold value,cycle min,cycle max,cycle step,adaptive contrast percent> 100 1 to 200
Quadrus MINI Imager User’s Manual
10-21
Page 288
Number of Symbols in Field of View
Number of Symbols in Field of View Definition: Serial Cmd: Default: Options:
This command allows the user to determine how FLM will behave in relation to the candidate symbols in the field of view. <K518,number of symbols in field of view> Any number of symbols 0 = Any number of symbols 1 = One symbol 2 = More than one symbol Note: When the number of symbols in the field of view is set to 1, codeword stitching from all scaled image processes is allowed for PDF417 and MicroPDF417. Note: This variable is used in Fast Linear Mode. FLM usually considers the whole image as one candidate, but when Number of Symbols in Field of View is set to 2, FLM will try to locate the candidates first and then decode. The symbols cannot be side-by-side - they must be parallel. Note: Number of Symbols in Field of View is not supported when QMode is enabled.
10-22
Quadrus MINI Imager User’s Manual
Page 289
Camera and IP Setup
Damaged Symbol Usage:
Definition:
Usage: Default: Options:
This feature is useful with badly damaged symbols in which finder patterns or clock patterns are distorted, margins are distorted or missing on one or both sides of a symbol, or portions of data are damaged. When enabled, the imager will make additional attempts and try different processes in order to decode the symbol. Due to the complexity of the algorithm required, enabling this feature could significantly increase decode time. <K519,damaged symbol status> Disabled 0 = Disabled 1 = Enabled Note: Damaged Symbol is not supported when Q-Mode is enabled.
Quadrus MINI Imager User’s Manual
10-23
Page 290
IP Mode
IP Mode Definition: Usage: Default: Options:
Determines the decode algorithm that will be used to process images. Important: Options 2 and 3 are not available in non-Q-Mode imagers. <K527,IP Mode,FLM direction> Both Standard Mode and Q-Mode 0 = Standard Mode 1 = Fast Linear Mode 2 = Q-Mode 3 = Both
Standard Mode In Standard Mode, the imager processes the image using the standard decode algorithm.
Fast Linear Mode In Fast Linear Mode, the imager quickly locates and decodes linear symbols that are oriented in the field of view in such a way that a horizontal or vertical scan line can pass completely through the symbol. The entire image is assumed to be a candidate, and is read horizontally, vertically, or in both directions. When the number of symbols in the field of view <K518> is set to 2, Fast Linear Mode will try to locate the candidates first and then decode. The candidate symbols cannot be side-by-side - they must be parallel.
Q-Mode In Q-Mode, the image is processed using a special algorithm that is designed to provide quick, consistent decode times. Standard Mode may be required for more challenging symbols. Note: The following items are not supported when Q-Mode is enabled: • • • • • • • • • • • • • • • • • • • • • •
Hollow Mode Number of Symbols in Field of View Damaged Symbol IP Threshold BC412 Symbology 2D Enhanced (Narrow Margins) Large Intercharacter Gap (Code 39) Large Intercharacter Gap (Codabar) Guard Bar Status (Interleaved 2 of 5) Codeword Collection (PDF417) Print Growth (ISO/IEC 16022 Symbol Quality Output) Axial Non-Uniformity (Data Matrix Only) (ISO/IEC 16022 Symbol Quality Output) Unused Error Correction (Data Matrix Only) (ISO/IEC 16022 Symbol Quality Output) Percent Cell Damage (Data Matrix Only) (Microscan Symbol Quality Output) Pixels Per Element (Data Matrix Only) (Microscan Symbol Quality Output) Error Correction Level (Data Matrix Only) (Microscan Symbol Quality Output) Matrix Size (Data Matrix Only) (Microscan Symbol Quality Output) Detailed No Read Message (No Read Message) Bad Symbol Message No Symbol Message 1D/Stacked Symbology Qualification 2D Symbology Qualification
Both Standard Mode and Q-Mode In Both, the imager attempts to process the image using both Standard Mode and Q-Mode. 10-24
Quadrus MINI Imager User’s Manual