Page 261

Matchcode

Wild Card Character Usage:

Definition: Serial Cmd: Default: Options:

Example: With Wild Card Character defined as the default asterisk, defining CR*34 as the master symbol will result in matches for CR134 and CR234, but not CR2345. Entering the wild card at the end of the master symbol, as in CR*, will result in matches for variable symbol lengths such as CR1, CR23, CR358, etc. Wild Card Character allows a user to define a wild card character as part of the master symbol. <K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> * (asterisk) Any ASCII character.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K223h,,,,,3C> For >: <K223h,,,,,3E> For , : <K223h,,,,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

Quadrus MINI Imager User’s Manual

9-7

Page 262

Matchcode Type

Sequence on No Read Usage: Definition: Serial Cmd: Default: Options:

Sequence on No Read is useful when the imager needs to stay in sequence even if no decode occurs. When Sequence on No Read is Enabled and Matchcode is set to Sequential, the imager sequences the master symbol on every match or No Read. When disabled, it does not sequence on a No Read. <K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> Enabled 0 = Disabled 1 = Enabled

As an example of Sequence on No Read Enabled, consider the following decodes: Master Symbol 001 002 003 004 005 006 007

Decoded Symbol 001 002 No Read 004 No Read No Read 007

Master Symbol after Decode 002 003 004 (sequenced on No Read) 005 006 (sequenced on No Read) 007 (sequenced on No Read) 008

As an example of Sequence on No Read Disabled, consider the following series of decodes: Master Symbol 001 002 003 003 004 004 004

9-8

Decoded Symbol 001 002 No Read 003 No Read No Read 004

Master Symbol after Decode 002 003 003 (not sequenced) 004 004 (not sequenced) 004 (not sequenced) 005

Quadrus MINI Imager User’s Manual

Page 263

Matchcode

Sequence on Mismatch Note: Matchcode must be set to Sequential for this command to function. Usage:

Definition:

Serial Cmd: Default: Options:

Enable this parameter if every trigger event should have a decode and more than one consecutive mismatch may occur. Disable this parameter if every trigger event should have a decode but no more than one consecutive mismatch may occur. When set to Enabled, the master symbol sequences on every decode, match, or mismatch. When set to Disabled, the master symbol will not sequence whenever consecutive mismatches occur. <K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> Disabled 0 = Disabled 1 = Enabled

The imager will sequence the master to one more or one less than the decoded symbol. As an example of Sequence on Mismatch Enabled, consider the following decodes: Master Symbol 001 002 003 004 005 006 007

Decoded Symbol 001 002 abc 004 def ghi 007

Master Symbol after Decode 002 003 004 (sequenced on mismatch) 005 006 (sequenced on mismatch) 007 (sequenced on mismatch) 008

As an example of Sequence on Mismatch Disabled, consider the following decodes: Master Symbol 001 002 003 004 005 006 006

Decoded Symbol 001 002 abc 004 def ghi 006

Quadrus MINI Imager User’s Manual

Master Symbol after Decode 002 003 004 (sequenced because of previous match) 005 006 (sequenced because of previous match) 006 (not sequenced) 007

9-9

Page 264

Match Replace

Match Replace Usage: Definition: Serial Cmd: Default: Options:

Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol. Outputs a user-defined data string whenever a match occurs and Matchcode is enabled. <K735,status,replacement string> Disabled 0 = Disabled 1 = Enabled

Replacement String Definition: Serial Cmd: Default: Options:

User-defined data string that, when enabled, replaces symbol data whenever a match occurs. <K735,status,replacement string> MATCH An ASCII string up to 64 characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K735h,,3C> For >: <K735h,,3E> For , : <K735h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

9-10

Quadrus MINI Imager User’s Manual

Page 265

Matchcode

Mismatch Replace Usage: Definition: Serial Cmd: Default: Options:

Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol. Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled. <K736,status,replacement string> Disabled 0 = Disabled 1 = Enabled

Replacement String Definition: Serial Cmd: Default: Options:

User-defined data string that, when enabled, replaces symbol data whenever a mismatch occurs. <K736,status,replacement string> MISMATCH An ASCII string up to 64 characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K736h,,3C> For >: <K736h,,3E> For , : <K736h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

Quadrus MINI Imager User’s Manual

9-11

Page 266

New Master Pin

New Master Pin Definition:

Serial Cmd: Default: Options:

If Matchcode and New Master Pin are enabled and the new master pin is momentarily connected to ground (must be held low for a minimum of 10 ms) master symbol information will be loaded into the database based on the next read cycle that achieves a Good Read, starting with Index 1. The Master Symbol Database will be loaded with all symbols decoded in the read cycle as long as it does not exceed the Number of Master Symbols parameter. <K225,status> Disabled 0 = Disabled 1 = Enabled

New Master Load Status Definition:

Serial Cmd:

9-12

The new master status responds with the number of the next master position to be loaded, where 0 represents “idle” or “no master to be loaded.” Example: If the user has the Number of Master Symbols set to 1, and then either sends a <G> or toggles an active New Master Pin, the state will be 1, and prior to reading and effectively loading position 1, the response to <NEWM> would be <NEWM/1>. Once a symbol has been read and loaded, the status will be cleared: <NEWM/0>. <NEWM>

Quadrus MINI Imager User’s Manual

Page 267

10 Camera and IP Setup Contents Camera and IP Setup by ESP .................................................................................................... 10-2 Camera and IP Setup Serial Commands.................................................................................... 10-3 Video........................................................................................................................................... 10-4 Evaluation ................................................................................................................................... 10-5 Calibration................................................................................................................................... 10-9 Window of Interest .................................................................................................................... 10-10 Configuration Database ............................................................................................................ 10-13 Dynamic Setup ......................................................................................................................... 10-14 Pixel Sub-Sampling .................................................................................................................. 10-15 Camera Settings ....................................................................................................................... 10-16 Focal Distance .......................................................................................................................... 10-17 Focal Distance Table (Read-Only) ........................................................................................... 10-18 Increment Focus Position ......................................................................................................... 10-19 Decrement Focus Position........................................................................................................ 10-19 IP Threshold ............................................................................................................................. 10-20 Number of Symbols in Field of View......................................................................................... 10-22 Damaged Symbol ..................................................................................................................... 10-23 IP Mode .................................................................................................................................... 10-24 Hollow Mode ............................................................................................................................. 10-26 Mirrored Image ......................................................................................................................... 10-27 Illumination Brightness.............................................................................................................. 10-28 Skew Correction ....................................................................................................................... 10-29

This section provides adjustment parameters for the physical controls of the camera, image acquisition, database settings, and image diagnostics.

Quadrus MINI Imager User’s Manual

10-1

Page 268

Camera and IP Setup by ESP

Camera and IP Setup by ESP Click this button to bring up the App Mode view.

Click this button to bring up the Camera Setup tree control.

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

10-2

Quadrus MINI Imager User’s Manual

Page 269

Camera and IP Setup

Camera and IP Setup Serial Commands IP Threshold

<K512,threshold mode,fixed threshold value,cycle min,cycle max,cycle step,adaptive contrast percent> Mirrored Image <K514,mirrored image> <K516,row pointer,column pointer,row depth,column Window of Interest width> Hollow Mode <K517,hollow mode status> Number of Symbols in Field of View <K518,number of symbols in field of view> Damaged Symbol <K519,damaged symbol status> Focal Distance <K525,focal distance> Increment Focus Position <K525+> Decrement Focus Position <K525–> Focal Distance Table (Read-Only) <K526,number of focal distances,focal distance> IP Mode <K527,IP Mode,FLM direction> Illumination Brightness <K536,brightness> Skew Correction <K537,line speed,symbol direction> Camera <K541,shutter speed,gain> Pixel Sub-Sampling <K542,sub-sampling>

Quadrus MINI Imager User’s Manual

10-3

Page 270

Video

Video The Video view is similar to the EZ Mode interface, in that the user has the ability to perform the same Locate, Calibrate, and Test routines. There is also a focal distance adjustment tool to the right of the video view. Video also features Capture and Decode functionality, which is similar to the Configuration interfaces (Communication, Read Cycle, Symbologies, I/O, Matchcode, and Diagnostics).

Initiates Calibration routine.

Activates the imager’s target pattern and initiates live video display of the symbol in the field of view.

Allows the user to take an image capture of the symbol in the field of view at any time, and to decode the symbol data. Similar to the Capture and Decode function in the Configuration views.

Initiates the Test routine. Allows the user to test the imager’s read rate and decodes per second, and also displays decoded symbol data in the field at the bottom of the screen, Click Stop to end the Test routine.

Clicking this icon enables the focal distance slide control to the right of the video view. The focal distance value is displayed just below the icon.

Symbol data and Test results are shown in this field.

10-4

When enabled, shows the symbol in higher contrast than the default contrast value.

Quadrus MINI Imager User’s Manual