Quick Start
Step 7, Locate the Symbol in the Field of View Locate by ESP • In ESP’s EZ Mode, click the Locate button to enable the blue target pattern.
The symbol in the field of view will appear in the video view beneath the Locate and Calibrate buttons, and you will see the blue target pattern projected from the front of the imager. • Center the target pattern on the symbol. At 2 to 3 inches, the pattern resembles an X. At 3 to 6 inches, the pattern resembles a V.
Center on object in field of view.
Target pattern shown as it would appear between 3 and 6 inches.
Important: The entire symbol should fall within the field of view (FOV) of the imager. The field of view is what appears in ESP’s Locate/Calibrate window in EZ Mode. • Click the Stop button to end the Locate function.
Quadrus MINI Imager User’s Manual
1-9
Page 22
Locate the Symbol in the Field of View
Locate by EZ Button If you are not connected to a host computer, the EZ Button allows you to locate a symbol in the imager’s field of view. EZ Button
• Hold down the EZ Button for about one second and release when you hear one short beep. The amber 20% LED will illuminate, and you will see the blue target pattern projected from the front of the imager. • Center the target pattern on the symbol. Note: To end all EZ Button functions, press the EZ Button once and quickly release.
1-10
Quadrus MINI Imager User’s Manual
Page 23
Quick Start
Step 8, Calibrate Quadrus MINI settings can be adjusted automatically for optimum symbol decoding performance by either the EZ Button or by ESP. During the calibration routine, the reader will flash its amber Read Rate percent LEDs and red illumination LEDs while searching camera settings and determining the best configuration for decoding symbol data. Upon successful completion of this routine, a green LED pattern will flash brightly and illuminate the symbol. If unsuccessful, the imager will emit 5 short beeps and stop searching.
Calibrate by EZ Button 1. Hold down the EZ Button for about two seconds and release when you hear two short beeps. The 20% and 40% LEDs will illuminate. 2. The imager will search camera settings to determine the best configuration for decoding symbol data. Note: To end all EZ Button functions, press the EZ Button once and quickly release.
Calibrate by ESP 1. Click the Calibrate button.
2. The imager will search camera settings to determine the best configuration for decoding symbol data. A successful calibration will display a green frame around the symbol, and the following message will appear: “Uploading all reader parameters.” After a moment the symbol data will be presented in the field below the image display window.
Calibrate by Serial Command Send <@CAL> from a terminal program to begin calibration.
Quadrus MINI Imager User’s Manual
1-11
Page 24
Test Read Rate
Step 9, Test Read Rate Read Rate indicates the number of successful decodes per second achieved by the imager.
Test Read Rate by EZ Button 1. To start the Read Rate test, hold down the EZ Button about three seconds until you hear three short beeps. The 20%, 40%, and 60% LEDs will illuminate. While the symbol is being inspected, the Read Rate LEDs will indicate the corresponding read rate percentage on the back of the unit.
20%, 40%, 60%, 80%, 100%. These LEDs represent the percentage of Good Reads per images captured.
2. To end the Read Rate test, press the EZ Button and quickly release.
Test Read Rate by ESP 1. Click the Test button to start the Read Rate test and Stop to end it.
If a symbol has been successfully decoded, the symbol’s data and related features will be presented in the field below the image display window. Also, while the symbol is being inspected, the Read Rate LEDs will indicate the corresponding Read Rate percentage on the back of the unit. 2. To end the test, click the Stop button. Note: Read Rate can also be tested using the Read Rate interface in Utilities.
Test Read Rate by Serial Command You can also start a test with the <C> or <Cp> command and end it with the <J> command.
1-12
Quadrus MINI Imager User’s Manual
Page 25
Quick Start
Step 10, Configure the Imager in ESP To make setup changes to Quadrus MINI, click the App Mode button.
The following modes are accessible by clicking the buttons in the first row of App Mode icons:
• Click the Autoconnect button to establish communications between ESP and the imager. • Click the Send/Recv button to send or receive commands. • Click the Camera button to access a live Video view, Evaluate image captures, Calibrate the imager, set the Window of Interest, fine-tune capture settings and processing settings in the Configuration Database, and control multiple read cycle functions in Dynamic Setup. • Click the Terminal button to display decoded symbol data, and to send serial commands to the imager using text or macros. • Click the Utilities button to test Read Rate, request or clear Counters, enable or disable the imager or send output pulses in Device Control, determine the Differences from Default in the current settings, add or remove master symbol data in Master Database, and verify or update the imager’s Firmware. • Click the Output Format button to determine the order and content of data output. Click the Configuration button to display the second row of ESP icons.
From here you can make changes in the tree controls that can be accessed by clicking the buttons on the second row of icons in the ESP window.
For further details, see Microscan ESP Help in the dropdown Help menu.
Quadrus MINI Imager User’s Manual
1-13
Page 26
Save Configuration in ESP
Step 11, Save Configuration in ESP To make changes to a configuration setting:
3. Place your cursor in the selection box, scroll down to the setting you want to change, and click once on the setting.
1. Left-click on the + to expand the desired tree. 2. Double-click on the desired parameter and click once in the selection box to view options. 4. Left-click again on the open screen to complete your selection.
5. Right-click on the open screen and select Save to Reader to implement the command in the imager.
Saving Options • Send, No Save. Changes will be lost when power is re-applied to the imager. • Send and Save. This activates all changes in current memory and saves to the imager for power-on.
1-14
Quadrus MINI Imager User’s Manual
Page 27
2 Using ESP Contents EZ Mode........................................................................................................................................2-2 Application Mode...........................................................................................................................2-3 Menu Toolbar ................................................................................................................................2-4 Autoconnect ................................................................................................................................2-12 View ............................................................................................................................................2-14 Navigating in ESP .......................................................................................................................2-15 Send/Receive Options ................................................................................................................2-16 Using EZ Trax .............................................................................................................................2-18
This section is designed to help you understand the basic structure and elements of ESP (Easy Setup Program). When you open ESP, unless otherwise specified in the ESP Preferences dialog accessible from the Options heading on the menu toolbar, you will enter EZ Mode for initial setup. From there, you can enter Application Mode (App Mode) and access several configuration menus (Communications, Read Cycle, Symbologies, I/O Parameters, Symbol Quality, Matchcode, and Diagnostics), a Camera setup interface, a Terminal interface, a Utilities interface, and an Output Format interface. ESP can be used to configure the Quadrus MINI in three different ways: • Tree Controls: Each configuration menu contains a list of all option settings that pertain to that specific element of imager operation. For example, the Communications menu shows a Host Port Connections option, and then a list of the sub-options Baud Rate, Parity, Stop Bits, and Data Bits. Each of these sub-options is configurable by using dropdown menus. • Graphic User Interfaces: Imager settings can be configured using such point-and-click tools as radio buttons, zoom in/zoom out sliders, spin boxes, check boxes, and drag-and-drop functions. • Terminal: ESP’s Terminal allows you to send serial configuration and utility commands directly to the imager by typing them in the provided text field. Information about using ESP in specific applications is provided in subsequent sections. For ESP system requirements, see ESP System Requirements in Chapter 1, Quick Start.
Quadrus MINI Imager User’s Manual
2-1
Page 28
EZ Mode
EZ Mode In EZ Mode you are presented with the Locate, Calibrate, and Test options. After connecting to your imager, EZ Mode is the screen you will see. You will be provided with on-screen instructions that will help you with positioning, testing, and calibration.
Test Click the Test button to start the Read Rate test for a quick indication of the imager’s read capabilities and the limits of your application. When Decodes per Second is unchecked, the test will count the percentage of decodes relative to the number of actual scans. Click Stop to end the test.
Calibrate The calibration routine that will optimize the imager by comparing Read Rates at various camera and image processing settings. Enter App Mode to access configuration trees and other setup features.
Click Calibrate to begin the initial calibration routine. Calbration is explained at the left of the EZ Mode screen, and also in Quick Start.
Click Locate to activate the Quadrus MINI’s blue target pattern LEDs. Center the target pattern on the symbol. The display shows you where the symbol is located in the imager’s field of view.
Starts Read Rate test.
Ends Read Rate test.
2-2
Quadrus MINI Imager User’s Manual
Page 29
Using ESP
Application Mode From EZ Mode, you can click on the App Mode button to access specific configuration menus, Utilities tools, Camera setup, Output Format options, and a Terminal window where serial commands can be entered.
Note: The App Mode and EZ Mode buttons appear in the same position to allow easy switching between these primary modes. Camera Setup, advanced Calibration, Configuration Database. Click this icon to return to EZ Mode.
Menu toolbar.
Click here to open the Terminal view.
Click here for Ordered Output and Output Format features.
Click on icons in this row to access configuration trees like the one shown here. Click the Configuration icon to return to full App Mode view from Camera, Terminal, Utilities, or Output Format.
Click Capture and Decode to read the symbol in the field of view, and to see a high resolution image capture of the symbol.
Decoded symbol data is shown in this table.
Note: For specific information on any of the icons shown above in the operations bar or configuration bar, see the corresponding chapters in this manual.
Quadrus MINI Imager User’s Manual
2-3
Page 30
Menu Toolbar
Menu Toolbar File > New Whenever New is selected, the default configuration of ESP is loaded.
Open/Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open. Important: When you save menu changes to your hard drive, these changes are not saved to your imager. The illustration below shows how settings can be saved and received between ESP and the imager, and ESP and the host hard drive.
(Save to Imager) (Receive Imager Settings)
Import/Export Import converts the ASCII settings from a text file to ESP configuration settings. Export converts the active ESP configuration settings to an ASCII text file.
2-4