Page 241

Symbol Quality

Overview of Symbol Quality Information about symbol quality and timing can be appended to symbol data by enabling specific evaluation parameters. The order in which these values are appended corresponds directly to the order in which they appear in ESP‘s Symbol Quality tree control. Symbol Quality parameters are separated into ISO/IEC 16022 Symbol Quality Output and Microscan Symbol Quality Output. Total Read Time, Symbol Quality Separator, and Output Mode are common to both ISO/IEC 16022 and Microscan Grading Parameters.

The enabled Symbol Quality parameters are appended to symbol data output in the order that they appear in the tree control.

If you enable the outputs shown above, they will be returned in this order:

Symbol Data

Locate Time (Microscan Grading)

Symbol Contrast (ISO/IEC 16022)

Decode Time (Microscan Grading)

0123456789abcdefghijklmnopqrstuv 256 A 30 210 3 17 Total Read Time

Pixels Per Element (Microscan Grading)

Capture Time (Microscan Grading)

Quadrus MINI Imager User’s Manual

8-3

Page 242

Symbol Quality by ESP

Symbol Quality by ESP Tree Control To open nested options, single-click the +. Click this button to bring up the App Mode view.

Click this button to bring up the Symbol Quality tree control.

To change a setting, double-click the setting and use your cursor to scroll through the options.

8-4

Quadrus MINI Imager User’s Manual

Page 243

Symbol Quality

Report Tab The Report tab allows the user to initiate Data Matrix Grading and to generate and save grading reports. To save the report as a PDF file, an HTML file, a CSV file, or an RTF file, click the Save Report button. Reports appear in the viewing area underneath the Data Matrix Grading and Save Report buttons.

The Symbol Quality interface is divided into three sections: Report, Locate, and Preferences.

The imager’s field of view is shown here. When grading is completed, the initial report is also shown in this viewing area.

Quadrus MINI Imager User’s Manual

8-5

Page 244

Symbol Quality by ESP

Locate Tab The Locate tab allows the user to determine the position of the symbol within the imager’s field of view, and to optimize the imager’s camera settings for symbol quality evaluation.

Click the Locate button to display the symbol in the imager’s field of view.

8-6

Click the Calibrate button to optimize camera settings.

Quadrus MINI Imager User’s Manual

Page 245

Symbol Quality

Preferences Tab The Preferences tab allows the user to set defaults that are automatically activated when grading is completed. For this reason, the user is advised to set preferences before performing grading.

This information is appended at the bottom of the report.

Choose the default report type to be generated when you click Save Report on the Report tab. Check Autofit Content to ensure that saved PDF report content will fit on a single page.

Typically you will be asked where you wish to store your report. If you do not want to be prompted to choose a file path, click Store Report without file path prompt.

Click the Include Image check box to output the captured symbol image with your saved report as a Bitmap or JPEG image file.

Enables ESP to parse UII symbol data into the correct fields and output order defined by the U.S. Department of Defense IUID initiative.

Returns all settings to default.

Returns all settings to most recent.

Quadrus MINI Imager User’s Manual

8-7

Page 246

Symbol Quality Separator/Data Matrix Output Mode

Symbol Quality Separator/Data Matrix Output Mode Symbol Quality Separator applies to both Symbol Quality groups: ISO/IEC 16022 Symbol Quality Output and Microscan Symbol Quality Output.

Symbol Quality Separator Definition: Serial Cmd: Default: Options:

Inserts a separator between each enabled field of the symbol quality output. <K708,symbol quality separator,output mode> <SP> (space character) Any ASCII character.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K708h,3C> For >: <K708h,3E> For , : <K708h,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

Symbol Quality Separator by ESP

When you double-click on the default separator SP, the Symbol Quality Separator Calculator appears. Use the calculator keypad for one-click separator configuration.

8-8

Quadrus MINI Imager User’s Manual

Page 247

Symbol Quality

Data Matrix Output Mode Note: Output Mode applies to ISO/IEC 16022 symbol quality parameters. Definition: Serial Cmd: Default: Options:

Output Mode specifies how the four output parameters, if enabled, are formatted. <K708,symbol quality separator,output mode> Grade 0 = Grade 1 = Value

Grade If in Grade Mode, a grade (A,B,C,D) is appended to the symbol data.

Value If in Value Mode, the calculated value for the given parameter is appended to the symbol data.

Quadrus MINI Imager User’s Manual

8-9

Page 248

ISO/IEC 16022 Symbol Quality Output

ISO/IEC 16022 Symbol Quality Output Symbol Quality Parameters for Data Matrix symbols specified by ISO/IEC 16022.

Symbol Contrast Usage: Definition:

Serial Cmd: Default: Options:

Lets the user know if contrast settings are less than acceptable. All the pixels that fall within the area of the test symbol, including its required zone, will be sorted by their reflectance values to select the darkest 10% and the lightest 10% of the pixels. The arithmetic mean of the darkest and the lightest pixels is calculated and the difference of the two means is the Symbol Contrast. (ANSI) Symbol Contrast grading is defined this way: A (4.0) if SC > 70% B (3.0) if SC > 55% C (2.0) if SC > 40% D (1.0) if SC > 20% F (0.0) if SC < 20% If enabled, the symbol contrast is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled

Print Growth Note: Print Growth is not supported when Q-Mode is enabled. Definition:

Serial Cmd: Default: Options: 8-10

The extent to which dark or light markings appropriately fill or exceed their module boundaries. These values are determined by counting pixels in the clock pattern of the binary digitized image, then comparing it to a nominal value and minimum and maximum values. The print growth grade is defined in this way: A (4.0) if -.050 < PG < 0.50 B (3.0) if -.070 < PG < 0.70 C (2.0) if -.085 < PG < 0.85 D (1.0) if -.10 < PG < 1.00 F (0.0) if PG < -1.00 or PG > 1.00 If enabled, the print growth is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled Quadrus MINI Imager User’s Manual

Page 249

Symbol Quality

Axial Non-Uniformity (Data Matrix Only) Note: Axial Non-Uniformity is not supported when Q-Mode is enabled. Definition:

Serial Cmd: Default: Options:

Axial non-uniformity is a measure of how much the sampling point spacing differs from one axis to another, namely AN = abs (XAVG YAVG) / ((XAVG + YAVG)/2) where abs () yields the absolute value. If a symbology has more than two major axes, then AN is computed for those two average spacings which differ the most. (ANSI) axial non-uniformity grading is defined this way: A (4.0) if AN < .06 B (2.0) if AN < .08 C (2.0) if AN < .10 D (1.0) if AN < .12 F (0.0) if AN > .12 If enabled, the axial non-uniformity is appended to the symbol data according the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled

Unused Error Correction (Data Matrix Only) Note: Unused Error Correction is not supported when Q-Mode is enabled. Definition:

Serial Cmd: Default: Options:

The correction capacity of Reed-Solomon decoding is expressed in the equation: e + 2d < d - p, where e is the number of erasures, d is the number of error correction code words, and p is the number of code words reserved for error detection. A (4.0) if UEC > .62 B (3.0) if UEC > .50 C (2.0) if UEC > .37 D (1.0) if UEC > .25 F (0.0) if UEC < .25 If enabled, the UEC is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled

Quadrus MINI Imager User’s Manual

8-11

Page 250

ISO/IEC 16022 Symbol Quality Output by ESP

ISO/IEC 16022 Symbol Quality Output by ESP ESP’s Symbol Quality interface allows you to evaluate Data Matrix symbols for compliance with ISO/IEC 16022 requirements. First, determine which ISO/IEC 16022 Parameters you need to evaluate, using the Symbol Quality tree control.

Once you have set these Data Matrix evaluation parameters, go to the Preferences Tab and set your Data Matrix Grading Report output preferences.

After your output preferences are set, click the Data Matrix Grading button.

There will be a wait of a few seconds, and then the evaluation results will appear in the Symbol Quality view, in a format similar to the one shown below.

If you want to view the results in a report format, click the Save Report button. The report will be output in the format you chose in the Preferences dialog.

8-12

Quadrus MINI Imager User’s Manual