Page 231
I/O Parameters
Quality Output Separator Definition: Serial Cmd: Default: Options:
The separator character separates quality output data from symbol data. <K704,separator,decodes/trigger status> , Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K704h,3C> For >: <K704h,3E> For , : <K704h,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
Decodes per Trigger Status Definition:
Serial Cmd: Default: Options:
When this feature is enabled, the imager enters a state where it processes frames as configured until the end of a read cycle, with or without a successful symbol decode. When the read cycle ends, the imager outputs any decoded symbol data along with the decodes per trigger count. <K704,separator,decodes/trigger status> 0 0 = Disabled 1 = Enabled
Quadrus MINI Imager User’s Manual
7-51
Page 232
Configuring EZ Trax Output
Configuring EZ Trax Output After you have set up your imager for EZ Trax, you can configure the software in three different ways: using the EZ Trax interface, using the tree controls in ESP, and using serial commands. For detailed information about how to use the EZ Trax user interface for configuration, refer to the Help menu in EZ Trax software, or the EZ Trax Quick Start Guide, available on the Microscan Tools CD.
Configuring EZ Trax Output by ESP To configure EZ Trax using ESP, first click the I/O button in App Mode to display the I/O Parameters tree control.
7-52
Quadrus MINI Imager User’s Manual
Page 233
I/O Parameters
EZ Trax Output When EZ Trax output is enabled, the imager will attempt to output all enabled EZ Trax options. EZ Trax will not function unless enabled.
Comm Port Selects the communication port that will be used to transfer image files.
Image Mode
Determines which read cycle condition triggers image file output.
Image Format
Selects the format of the image output file.
Quadrus MINI Imager User’s Manual
7-53
Page 234
Configuring EZ Trax Output
JPEG Quality Sets the amount of JPEG image compression. A value of 1 represents the highest compression and lowest image quality, and 100 represents the lowest compression and highest image quality.
Object Info Output
If a symbol is decoded during an image capture, the symbol type and other supplementary symbol information is also included.
Grade Output
Symbol quality information will be output in the form of an abbreviated identifier for each read cycle.
7-54
Quadrus MINI Imager User’s Manual
Page 235
I/O Parameters
Configuring EZ Trax Output by Serial Command Usage: Definition: Serial Cmd: Default: Options:
Useful for when you want to configure EZ Trax output using serial commands instead of the EZ Trax graphic interface. When EZ Trax output is enabled, the imager will attempt to output all enabled EZ Trax options. EZ Trax will not function unless enabled. <K757,status,comm port,image mode,image format,JPEG quality,object info output, grade output> Disabled 0 = Disabled 1 = Enabled
Comm Port Definition: Serial Cmd: Default: Options:
Selects the communication port that will be used to transfer image files. <K757,status,comm port,image mode,image format,JPEG quality,object info output, grade output> Host 0 = Host 1 = Aux 2 = USB
Host Port Sends output using the current Host Port.
Aux Port Sends output using the Auxiliary Port.
USB Sends output using a USB connection.
Image Mode Definition: Serial Cmd: Default: Options:
Determines which read cycle condition triggers image file output. <K757,status,comm port,image mode,image format,JPEG quality,object info output, grade output> Disabled 0 = Disabled 1 = Good Read 2 = No Read 3 = No Read and Good Read 4 = Mismatch
Good Read Outputs the first Good Read image in the read cycle. The image file will immediately follow the symbol data.
Quadrus MINI Imager User’s Manual
7-55
Page 236
Configuring EZ Trax Output
No Read Outputs the first No Read image in the read cycle. The image file will immediately follow the symbol data. Note: If two symbols are present in the same image capture and one of them is successfully decoded, no image will be output.
No Read and Good Read Outputs the first No Read or Good Read image in the read cycle.
Mismatch Outputs the image of the first mismatch condition.
Image Format Definition: Serial Cmd: Default: Options:
Selects the format of the image output file. <K757,status,comm port,image mode,image format,JPEG quality,object info output, grade output> Compressed 0 = Lossless 1 = Compressed
Lossless A “lossless” image is one that is in a high resolution format, and that will not lose resolution even when manipulated and saved multiple times. When Lossless is enabled, the JPEG Quality setting has no effect.
Compressed Outputs the image in JPEG format. Image quality is determined by the JPEG Quality setting.
JPEG Quality Definition:
Serial Cmd: Default: Options:
7-56
Sets the amount of JPEG image compression. A value of 1 represents the highest compression and lowest image quality, and 100 represents the lowest compression and highest image quality. <K757,status,comm port,image mode,image format,JPEG quality,object info output, grade output> 90 1 to 100 (percent)
Quadrus MINI Imager User’s Manual
Page 237
I/O Parameters
Object Info Output Definition: Serial Cmd: Default: Options:
If a symbol is decoded during an image capture, the symbol type and other supplementary symbol information is also included. <K757,comm port,image mode,image format,JPEG quality,object info output, grade output> Disabled 0 = Disabled 1 = Enabled
Grade Output Definition: Serial Cmd: Default: Options:
Symbol quality information will be output in the form of an abbreviated identifier for each read cycle. <K757,comm port,image mode,image format,JPEG quality,object info output, grade output> Disabled 0 = Disabled 1 = Enabled
Quadrus MINI Imager User’s Manual
7-57
Page 238
Configuring EZ Trax Output
7-58
Quadrus MINI Imager User’s Manual
Page 239
8 Symbol Quality Contents Symbol Quality Serial Commands ................................................................................................ 8-2 Overview of Symbol Quality.......................................................................................................... 8-3 Symbol Quality by ESP................................................................................................................. 8-4 Symbol Quality Separator/Data Matrix Output Mode.................................................................... 8-8 ISO/IEC 16022 Symbol Quality Output....................................................................................... 8-10 ISO/IEC 16022 Symbol Quality Output by ESP.......................................................................... 8-12 Microscan Symbol Quality Output .............................................................................................. 8-13 Microscan Symbol Quality Output by ESP ................................................................................. 8-16
This section describes parameters that, when enabled, will output detailed symbol quality evaluations. Important: Symbol Quality output is not supported when Q-Mode is enabled.
Quadrus MINI Imager User’s Manual
8-1
Page 240
Symbol Quality Serial Commands
Symbol Quality Serial Commands Symbol Quality Separator/ Data <K708,symbol quality separator,data matrix output mode> Matrix Output Mode ISO/IEC 16022 Symbol Quality <K709,symbol contrast,print growth,axial non-uniformity, unused ECC> Output Microscan Symbol Quality Output <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Static Validation Report <VAL>
8-2
Quadrus MINI Imager User’s Manual