Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Data Collection Browser Client User's Guide

Manual · Intermec

Data Collection Browser Client User's Guide

Manual107 pagesPDF 897 KB

User's guide for the Intermec Data Collection Browser (dcBrowser) client on Trakker Antares, JANUS, 502X, RT1700, 6400 and 700 Series devices.

What this file really is

The old site listed this file as “Browser Guide” for the Intermec 2475 and 6400. The file is named as a 2475 user manual, but it is the Data Collection Browser Client User's Guide, a software guide that does not mention the 2475 by number.

Download the PDF897 KB

Names · 1 model

The models it names

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

Intermec's guide to the Data Collection Browser (dcBrowser) client, which runs HTML applications on Intermec data collection devices through a dcBrowser gateway on a DCS 30X or a software-only gateway. It explains the supported HTML 3.2 features and special tags, setting up a test environment with the simulator, and loading, configuring and running the client on Trakker Antares terminals, JANUS devices, 502X data collection PCs, RT1700 and 6400 devices and 700 Series mobile computers, with a troubleshooting chapter.

Its parts

  1. Before You Begin
  2. Chapter 1 - Getting Started
  3. Chapter 2 - Developing and Testing Your Application
  4. Chapter 3 - Trakker Antares Terminals
  5. Chapter 4 - JANUS Devices
  6. Chapter 5 - 502X Data Collection PCs
  7. Chapter 6 - RT1700 and 6400 Devices
  8. Chapter 7 - 700 Series Mobile Computer
  9. Chapter 8 - Troubleshooting

From the manual

Key facts from this manual

Each line names its page in the PDF.

This is Intermec's Data Collection Browser Client User's Guide (version 004, 01/02), not a manual for one terminal. It explains how to build and test HTML applications for dcBrowser and how to load and run the client on Trakker Antares terminals, JANUS devices, 502X Data Collection PCs, RT1700 and 6400 devices and the 700 Series Mobile Computer. The 2475 is not named in it.

Read for this summary: pages 1 to 3, 5 to 7, 9 to 12, 15 to 17, 21, 47 to 51, 71 to 79 and 91 to 92 of 107.

Software
Intermec Data Collection Browser (dcBrowser) client, which runs HTML applications on Intermec data collection devices p. 15
HTML support
A subset of HTML 3.2 syntax and the HTTP 1.0 standard p. 21
Gateway
A dcBrowser gateway on the DCS 30X, or the software-only gateway, turns HTML 3.2 pages into condensed ASCII for the device p. 15
Protocols
Device to gateway: TCP/IP, UDP Plus or WTP; gateway to web server: HTTP over TCP/IP p. 16
Network port
4055 for TCP/IP, 05555 for UDP Plus p. 91
File transfer
6400: TFTP (Windows 2000, Windows NT, Windows XP), Interlnk/Intersvr or the FileCopy utility p. 72, 74
6400 setups
6400: original terminal emulation with Native terminal emulation, or the TCP/IP bundle for the WLI Forum OpenAir or 802.11b radio p. 72
6400 client files
6400: N6400.EXE (client), PSKNET.INI (host and protocol), IMDCB.INI (scanner symbologies), 64SCN7A.EXE (scanner TSR), RL2PCM.COM (OpenAir radio driver), ITC64XFR.EXE (file transfer) p. 71, 72, 73
6400 protocols
6400: TCP/IP or WTP, chosen in the PSKNET.INI file p. 71, 76
6400 FileCopy link
6400 with ITC64XFR.EXE: XMODEM 1K, 19200 baud, no parity, 8 data bits, 1 stop bit p. 73
Trakker Antares client
Trakker Antares: client file DCBT24.BIN on drive C, loaded with FileCopy, LOADER.EXE, reader commands or a host application p. 47, 48
Related manuals
6400 Hand-Held Computer User's Manual (Part No. 961-047-093); 6400 Application Development Tools System Manual (Part No. 070130); RT1700 Radio Data Terminal User's Guide (Part No. 961-047-068) p. 71, 72

What this manual walks you through

  • Understanding the development, test and runtime environments p. 17
  • Checking for and loading the dcBrowser client on Trakker Antares terminals p. 47, 48, 49
  • Setting the gateway IP address and network port on Trakker Antares terminals p. 49, 50
  • Using the RT1700 with the dcBrowser gateway p. 71
  • Setting the 6400 network configuration with chgparms p. 73
  • Moving files to a 6400 with TFTP, Interlnk/Intersvr or FileCopy p. 74, 75, 76, 78
  • Editing PSKNET.INI for WTP or TCP/IP p. 76
  • Starting and running the dcBrowser client on the 6400 p. 79
  • Troubleshooting connection, gateway and scanner problems p. 91, 92

Good to know

  • dcBrowser does not work with the 2460 and 2461 terminals or with the Model 200 Controller. p. 11
  • The DCS 300 can download the dcBrowser client only to UDP Plus terminals. p. 48
  • Interlnk/Intersvr are not available in Windows NT and Windows 2000; use TFTP there. p. 74
  • The RT1700 does not support highlighting and tab to anchors. p. 71
  • After the DCS 30X reboots, response is slower than expected for about 30 minutes. p. 91

Questions this manual answers

How do I run dcBrowser on an Intermec 6400?

Use a 6400 with Native terminal emulation or the TCP/IP bundle, load N6400.EXE and PSKNET.INI, then type loadscan and n6400. p. 71, 72, 79

What network port does dcBrowser use?

4055 for TCP/IP devices and 05555 for UDP Plus devices. p. 49

The 6400 scanner does not work in dcBrowser. What should I check?

Check that 641223.EXE or 64SCN7B.EXE starts on reboot in AUTOEXEC.BAT, and that 64SCN7A.EXE runs before N6400.EXE. p. 92

How do I send files to a 6400 with TFTP?

Set the 6400's IP address and radio link, type tftp serve at its DOS prompt, then use tftp -i with put from a DOS session on the PC. p. 74

Which HTML version does Intermec dcBrowser support?

A subset of HTML 3.2, plus the HTTP 1.0 standard; content the device cannot show is filtered out. p. 21

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Before You Begin9
    1. Warranty Information9
    2. Safety Summary9
    3. Cautions and Notes10
    4. About This Manual10
    5. Other Intermec Manuals12
  2. Chapter 1 - Getting Started13
    1. Learning About the Data Collection Browser15
    2. About the Environments17
  3. Chapter 2 - Developing and Testing Your Application19
    1. About the Development Environment21
    2. Supported HTML Features21
    3. Unsupported HTML Features22
    4. Summary of HTML 3.2 Tags23
    5. Special HTML Tags26
    6. Example Web Page and HTML Code33
    7. Advanced Features36
    8. About the Test/Software Only Gateway Environment37
    9. Setting Up the Test/Software Only Gateway Environment38
    10. Configuring the Test/Software Only Gateway Environment42
    11. Testing Your Application44
    12. Setting Up the Runtime Environment44
  4. Chapter 3 - Trakker Antares Terminals45
    1. Overview47
    2. Verifying the dcBrowser Client is Loaded47
    3. Loading the dcBrowser Client48
    4. Configuring Your Trakker Antares Terminals49
    5. Connecting to the dcBrowser Gateway51
    6. Running the dcBrowser Client51
  5. Chapter 4 - JANUS Devices53
    1. Overview55
    2. Loading and Configuring the dcBrowser Client55
    3. Connecting to the dcBrowser Gateway59
    4. Running the dcBrowser Client60
  6. Chapter 5 - 502X Data Collection PCs61
    1. Overview63
    2. Installing and Configuring the dcBrowser Client63
    3. Connecting to the dcBrowser Gateway66
    4. Running the dcBrowser Client67
  7. Chapter 6 - RT1700 and 6400 Devices69
18 more lines, from page 71 on
  1. Overview71
    1. Using the dcBrowser Gateway on the RT170071
    2. Verifying the dcBrowser Client Is Loaded71
    3. Loading the dcBrowser Client72
    4. Starting the dcBrowser Client79
    5. Running the dcBrowser Client79
  2. Chapter 7 - 700 Series Mobile Computer81
    1. Overview83
    2. Configuring and Starting the dcBrowser Client83
    3. Using ActiveSync84
    4. Connecting to the dcBrowser Gateway87
    5. Running the dcBrowser Client88
  3. Chapter 8 - Troubleshooting89
    1. Symptoms and Solutions91
    2. Using the Intermec Product Support Web Page92
  4. Appendix A - ASCII to Hex Conversion95
    1. ASCII to Hex Conversion97
  5. Index99

From the PDF’s own bookmarks.

The whole text · 14 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Before You Begin9-12
  3. Chapter 1 - Getting Started13-18
  4. Chapter 2 - Developing and Testing Your Application, pages 19 to 2719-27
  5. Chapter 2 - Developing and Testing Your Application, pages 28 to 3628-36
  6. Chapter 2 - Developing and Testing Your Application, pages 37 to 4437-44
  7. Chapter 3 - Trakker Antares Terminals45-52
  8. Chapter 4 - JANUS Devices53-60
  9. Chapter 5 - 502X Data Collection PCs61-68
  10. Chapter 6 - RT1700 and 6400 Devices69-80
  11. Chapter 7 - 700 Series Mobile Computer81-88
  12. Chapter 8 - Troubleshooting89-94
  13. Appendix A - ASCII to Hex Conversion95-98
  14. Index99-107

The file

Revision and size

RevisionVersion 004, 01/02
PublisherIntermec Technologies Corporation
Pages107
PDF897 KB
TextText from the PDF itself; pages 1 and 77 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 107

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 107
Page 2
Page 2of 107
Page 3
Page 3of 107