The text of a manual · part 9 of 14
Data Collection Browser Client User's Guide: Chapter 5 - 502X Data Collection PCs
Pages 61 to 68 of 107, from Data Collection Browser Client User's Guide
The original document is the PDF (897 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6400
Page 61
5 502X Data Collection PCs
Page 62
abc
Page 63
502X Data Collection PCs
5
This chapter explains how to load and run the dcBrowser client on your 502X Data Collection PC.
Overview Use this chapter to • install and configure the dcBrowser client.
• connect to the dcBrowser gateway.
• run the dcBrowser client.
Installing and Configuring the dcBrowser Client You can use the Application Manager component of Unit Manager or ActiveSync to load the dcBrowser client on your 502X. •
Use File Manager to load applications on your 502X device over a network.
•
Use ActiveSync to load applications on your 502X device. The first time you connect to ActiveSync, you must connect the 502X device to your PC’s serial port and establish a connection. After the initial connection, you can connect to ActiveSync over the radio network. You can establish a serial link using an L502X Serial Communications Adapter, a D502X Serial Communications Dock, or a serial I/O card in the PC card slot.
For more information about Application Manager and ActiveSync, see the 502X Data Collection PC System Manual (Part No. 071479).
To install the dcBrowser client on the 502X 1. Press 2. Press
!
, and then press or
& to open the Start menu.
& to highlight Run, and then press .
3. Select Browse, and then press .
Note: You can also choose to delete the CAB file as it is installed. Type setup/d yourfile.CAB in the Run dialog box, where yourfile is the name of the CAB file. Press . The application will be installed and the CAB file deleted.
&
4. Select the Windows list box.
&
5. Select the CAB file, and press .
5-3
Page 64
Data Collection Browser Client User’s Guide
The 502X system software automatically associates the CAB file with SETUP.EXE and installs the application. SETUP.EXE extracts the entire contents of the CAB file into the \SETUPMP directory. SETUP.EXE then uses the information in the INF file to copy files to their destinations, make registry changes, configure the application on the 502X, store the INF file in the application directory, and store the uninstall information in the registry. Note: When you run SETUP.EXE, the contents of the CAB file are preserved. You can also use /D, /d, /delete, or /DELETE to remove the CAB file as the setup process progresses. If the CAB file you are installing is very large or the available space on the 502X is limited, you may need to use the /DELETE option, which frees more program memory by reducing the size of the CAB file as application files are extracted. IMPORTANT! SETUP.EXE writes status messages about the installation to the SETUP.LOG file. The SETUP.LOG is a text file located in the WINDOWS directory of the 502X. Errors or problems with the installation are not displayed on the 502X screen; only the messages in the SETUP.LOG indicate what has occurred. To configure TCP/IP on the 502X 1. Run the Configuration application. 2. From the Network menu, choose Advanced, and ensure that UDP Plus is disabled. 3. Choose Radio, and give the 502X an IP address and subnet mask. If you have an 802.11B HR radio, give the network name under NETWORK. If you have a 2.4 GHz OpenAir radio, give a domain number and security ID number, if set. To start TCP/IP on the 502X 1. Start dcBrowser from the run menu or the desktop icon, if set. 2. To set the IP and port number of the dcBrowser gateway, press Ctrl-F1 when the splash screen appears showing the title and version number. 3. Press Enter to save your configuration. To configure UDP Plus on the 502X
!
1. Run the Configuration application. 2. Press
& to access the Configure menu.
3. Press to select Network, and then press . The Network configuration screen appears.
5-4
Page 65
502X Data Collection PCs
5
The 502X Network Configuration Screen
4. Select and enable UDP Plus, and configure any UDP Plus parameters. For help, see the 502X Data Collection PC System Manual.
9
5. Press to expand the UDP Plus parameter list. For a definition of each parameter, see the 502X Data Collection PC System Manual. 6. Set the Controller IP Address to the IP address of the DCS 30X or the dcBrowser gateway.
!
7. Select the Apply button, and then press 8. Press 9. Press
& & to save your changes.
to exit the Configuration application.
to highlight Exit, and then press .
10. Warm boot the 502X to enable UDP Plus parameters. For help, see the 5020 Data Collection PC User's Manual (Part No. 068975) or 5023 Data Collection PC User’s Manual (Part No. 070698). icon appears and After you have configured the 502X for a UDP Plus network, the remains on in the Notification Tray indicating that the 502X is communicating with the icon appears, see the 5020 Data Collection PC User's dcBrowser gateway. If the Manual or 5023 Data Collection PC User’s Manual.
5-5
Page 66
Data Collection Browser Client User’s Guide
Connecting to the dcBrowser Gateway After you have loaded and configured the dcBrowser client on your 502X, change the following parameters in the INI file for the dcBrowser gateway: Parameter
Change Value to
INPUT_HIGHLIGHT
INVERSE
ANCHOR_HIGHLIGHT
UNDERLINE
SUBMIT_HIGHLIGHT
UNDERLINE
TAB_TO_SUBMIT
TRUE
TAB_TO_ANCHOR
TRUE
For the software only dcBrowser gateway, the INI file is DCB.INI. For the dcBrowser on a DCS 30X, the INI file is WBS.INI. To change the INI parameters 1. Open the INI file in a text editor such as Notepad. 2. Change the parameters to the required values. 3. Save the changes to the INI file. 4. Exit the text editor. You are now ready to start the dcBrowser client and connect to the gateway. To start the dcBrowser client on your 502X •
Choose Run from the Start menu.
If you installed the application using the CAB method, press Ctrl-Esc until the dcBrowser icon is highlighted, and then press Enter.
5-6
Page 67
502X Data Collection PCs
5
Running the dcBrowser Client When you are running your HTML application, follow these guidelines: •
Use the cursor keys or Tab key to navigate from field to field.
•
Use the device’s scanner or keyboard to enter data.
•
Use auto-transmit fields to simplify data input. For help, see “Using Auto-Transmit Fields” in Chapter 2.
•
Press the appropriate function key to access the hypertext links or input buttons.
•
Press Ctrl-
/ to return to the home page.
This table lists special dcBrowser client key combinations that you may want to use while you are running your HTML application. Client Keys
Description
Ctrl-
Clear screen
Ctrl-
Restart communications with dcBrowser gateway
Ctrl-
Ping the dcBrowser gateway
Ctrl-
Toggle Timing mode
Ctrl-
Refresh screen
Ctrl-
Increase volume
Ctrl-
Decrease volume
Ctrl-
Exit the dcBrowser client
" / 3 6 :
V 7
(
A configuration screen appears the first time you start the dcBrowser client. You can restart this configuration screen by pressing Ctrl- at the splash screen.