This chapter explains how to determine if the dcBrowser client is loaded on your JANUS device and how to load and run the dcBrowser client.
Overview Use this chapter to • load the dcBrowser client.
• configure the dcBrowser client.
• connect to the dcBrowser gateway.
• run the dcBrowser client.
Note: JANUS 900 MHz and batch devices do not support dcBrowser. JANUS UDP Plus devices do not support dcBrowser.
Loading and Configuring the dcBrowser Client This section explains how to load the dcBrowser client (DCBJ24T.EXE) on your JANUS devices using the JANUS Image Manager utility, which ships on the dcBrowser client CD. When you installed the simulator, this utility loaded in the \INTERMEC\TOOLS\JANUSIMAGEMANAGER directory on your PC. For help using this utility, see the online help. To load the dcBrowser client on your JANUS device, you must use the JANUS Image Manager utility v1.71 or later, and you must have a disk with FTP PC/TCP v5.0. To load DCBJ24T.EXE on your devices 1. Connect the JANUS device to your PC. For help, see your JANUS device user’s manual. 2. On the PC, start the JANUS Image Manager utility. The Device Selection dialog box appears.
4-3
Page 56
Data Collection Browser Client User’s Guide
The Device Selection Dialog Box
3. Choose the JANUS device that you connected to your PC, and then choose 2.4 GHz. 4. Fill in the rest of the fields, and then choose the right arrow. The Load Images dialog box appears.
4-4
Page 57
JANUS Devices
4
5. Fill in the fields, and then choose the right arrow. The Network and Protocol dialog box appears.
6. Choose Customer application and PC/TCP (FTP Corp.), and then choose the right arrow. The FTP PC/TCP Options dialog box appears.
7. Insert the FTP PC/TCP v5.0 disk in the disk drive. Enter the path name in the PC/TCP for DOS field.
4-5
Page 58
Data Collection Browser Client User’s Guide
8. Fill in the rest of the fields and choose the right arrow. The Radio Parameters dialog box appears.
9. Fill in the fields and choose the right arrow. The Manager Images dialog box appears.
10. In the first PC column, click the directory that contains the DCBJ24T.EXE file. The default directory is \INTERMEC\DCBROWSER\CLIENT\JANUSTCP. 11. Copy the DCBJ24T.EXE file to the middle JANUS C: column.
4-6
Page 59
JANUS Devices
4
12. In the JANUS C: column, double-click AUTOEXEC.BAT. A text editor opens the AUTOEXEC.BAT file. 13. Find and delete these two lines: IF EXIST APP.BAT CALL APP.BAT IF EXIST UNNET.BAT CALL UNNET.BAT
You can also add a REM before each of these lines rather than delete them. 14. Choose the Make, Save, and Load icon (JANUS device). The new image with the dcBrowser client is downloaded to your JANUS device. You do not need to configure the JANUS device for the host IP address or the network port. You can define these parameters when you run the application, or you can create a batch file that automatically runs the dcBrowser client. You add this batch file to the JANUS C drive. The following example also frees up space on the JANUS C drive by unloading the reader wedge TSR.
Example Batch File rwtsr dcbj24t dcbrowsergatewayIP 4055 rwtsr -d where dcbrowsergatewayIP is the dcBrowser gateway IP address.
Connecting to the dcBrowser Gateway •
From the command line, type: DCBJ24T dcbrowsergatewayIP 4055 where dcbrowsergatewayIP is the DCS 30X or dcBrowser gateway IP address. The device’s home page appears. The home page is the starting screen of the application. If you need to restart the home page or if communication between the client and the dcBrowser gateway is disconnected, press to restart communications with the dcBrowser gateway.
</
4-7
Page 60
Data Collection Browser Client User’s Guide
Running the dcBrowser Client When you are running your HTML application, follow these guidelines: •
Use the cursor keys to navigate from field to field.
•
Use the device’s scanner or keyboard to enter data.
•
Use auto-transmit fields with scan-ahead data and type-ahead data. For help, see “Using Auto-Transmit Fields” in Chapter 2.
•
Access the hypertext links by pressing the appropriate function key.
•
Press to restart communications with the dcBrowser gateway if your device has been inactive for a period of time.
</
If you reboot the device, the device restarts the dcBrowser client when it finishes rebooting. This table lists special dcBrowser client key combinations that you may want to use while you are running your HTML application. Client Keys
Description
Ctrl-
Clear screen
Ctrl-
Toggle Debug mode
" # </ 3 6 ; X : V -
4-8
Restart communications with dcBrowser gateway
Ctrl-
Ping the dcBrowser gateway
Ctrl-
Toggle Timing mode
Ctrl-
Refresh screen
Ctrl-
Decrease contrast
Ctrl-
Increase contrast
Ctrl-
Increase volume
Ctrl-
Decrease volume