The text of a manual · part 7 of 14
Data Collection Browser Client User's Guide: Chapter 3 - Trakker Antares Terminals
Pages 45 to 52 of 107, from Data Collection Browser Client User's Guide
The original document is the PDF (897 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6400
Page 45
3 Trakker Antares Terminals
Page 46
abc
Page 47
adTrakker Antares Terminals
3
This chapter explains how to determine if the dcBrowser client is loaded on your Trakker Antares terminal and how to load and run the dcBrowser client.
Overview Use this chapter to • verify that the dcBrowser client is loaded.
• load the dcBrowser client if it is not loaded.
• configure your Trakker Antares terminals.
• connect to the dcBrowser gateway.
• run the dcBrowser client.
Verifying the dcBrowser Client is Loaded If your Trakker Antares TCP/IP or UDP Plus terminals came preloaded with the dcBrowser client, go to “Configuring Your Trakker Antares Terminals,” later in this chapter. To determine if you have the dcBrowser client loaded on your terminal 1. On your terminal, access the Trakker Antares 2400 Menu System by pressing or by scanning this bar code:
T
Enter Test and Service Mode
*..-.* *..-.*
Note: If your terminal has a Left Enter key, you must use it when entering the key sequences in Step 1; otherwise, just use the key. 2. Choose System Menu from the Main Menu, and then choose File Manager.
3. Select drive C and press . A list of applications that are loaded on your terminal appears. Look through this list for DCBT24.BIN, which is the dcBrowser client filename. If you have the dcBrowser client loaded on your terminal, go to “Configuring Your Trakker Antares Terminals,” later in this chapter. If you do not have the dcBrowser client loaded, go to the next section, “Loading the dcBrowser Client.”
3-3
Page 48
Data Collection Browser Client User’s Guidelk
Loading the dcBrowser Client This section explains how to load the dcBrowser client on your terminals. You can load the dcBrowser client on your terminals in one of the following four ways: Note: Currently, you can use the DCS 300 to download the dcBrowser client only to your UDP Plus terminals. •
Use the Windows-based FileCopy utility.
•
Use the DOS utility, LOADER.EXE.
•
Use the Receive File or Transmit File reader commands.
•
Use a host application.
This section explains how to use the FileCopy utility. For help using LOADER.EXE, reader commands, or a host application, refer to your Trakker Antares terminal user’s manual. The FileCopy utility ships on the dcBrowser client CD. When you installed the simulator, this utility was loaded in the \INTERMEC\TOOLS\FILECOPY directory on your PC. To load DCBT24.BIN on your terminals using the FileCopy utility 1. Connect the terminal to your PC. For help, see your Trakker Antares terminal user’s manual. 2. Run FileCopy. The Intermec FileCopy Utility dialog box appears.
3-4
Page 49
adTrakker Antares Terminals
3
3. Click the Terminal Type field down arrow. A list of terminals that the FileCopy utility supports appears. Choose TRAKKER. 4. Check the COM port parameters and the serial parameters to verify that the settings for your PC match the values that are set for the terminal’s serial port. The FileCopy online help contains detailed information about using the utility. Use the Trakker Antares 2400 Menu System to configure the serial port parameters on the terminal. For help, see the Trakker Antares terminal user’s manual. 5. If you are in the Trakker Antares 2400 Menu System, exit the menu system. 6. Select the FileCopy tab. 7. In the PC filename and path box, type: C:\INTERMEC\DCBROWSER\CLIENT\TRAKKER\DCBT24.BIN
8. In the Terminal filename and path box, type: C:DCBT24.BIN
9. Choose Download. The dcBrowser client is downloaded to your terminal.
Configuring Your Trakker Antares Terminals Before the Trakker Antares terminal can communicate with the dcBrowser gateway, you must set the host IP address or the controller IP address to the dcBrowser gateway IP address. You must then set the network port to 4055 for TCP/IP terminals or 05555 for UDP Plus terminals. To configure the network port 1. On your terminal, access the Trakker Antares 2400 Menu System by pressing or by scanning this bar code:
T
Enter Test and Service Mode
*..-.* *..-.*
Note: If your terminal has a Left Enter key, you must use it when entering the key sequences in Step 1; otherwise, just use the key.
3-5
Page 50
Data Collection Browser Client User’s Guidelk
2. From the Main Menu, choose Configuration Menu, Communications Menu, and then Primary Network. The Primary Network screen appears. TCP/IP
UDP Plus
PRIMARY
NETWORK
Activate: Disabled Host
IP
Addr:
0.0.0.0. Terminal
IP
Address:
0.0.0.0.
OK
CANCEL
PRIMARY
NETWORK
Activate: Disabled Controller IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
OK
CANCEL
DCBG001.eps
DCBG001.eps
3. Set the Activate field to 2.4 GHz RF, Ethernet, or 802.11. 4. Set the Host IP Address field or the controller IP address to the dcBrowser gateway IP address. 5. Set the Terminal IP Address field to the IP address of the terminal and press The Communications menu appears.
6. Choose Advanced Network. The Advanced Network screen appears. TCP/IP
UDP Plus
ADVANCED
NETWORK
Network Port: 4055 Subnet Mask: 255.255.255.0 Default Router 0.0.0.0. TCP/IP Maximum Transmit Timeout: 020 sec
OK
OK
CANCEL
CANCEL
DCBG004.eps
ADVANCED
NETWORK
Network Port: O5555 Subnet Mask: 255.255.255.0 Default Router 0.0.0.0. TCP/IP Maximum Transmit Timeout: 020 sec
OK
OK
CANCEL
CANCEL
DCBG003.eps
7. Set the Network Port field to 4055 for TCP/IP or 05555 for UDP Plus and press . The Communications menu appears. You may still need to configure your terminals to communicate with the access points. For help, see your terminal user’s manual and your access point user’s manual.
3-6
Page 51
adTrakker Antares Terminals
3
Connecting to the dcBrowser Gateway After you start the Web server and the dcBrowser gateway, you can start running your HTML application on your devices. To connect to the dcBrowser gateway •
Scan this bar code: Run Program C:DCBT24.BIN
*/O/OC/ZDCBT24.BIN* *//C:DCBT24.BIN*
Or, 1. On your terminal, access the Trakker Antares 2400 Menu System by pressing or by scanning this bar code:
T
Enter Test and Service Mode
*..-.* *..-.*
Note: If your terminal has a Left Enter key, you must use it when entering the key sequences in Step 1; otherwise, just use the key.
2. From the Main Menu, choose System Menu, and then choose File Manager. The File Manager screen appears.
A list of applications that are loaded on your terminal 4. Select DCBT24.BIN and press The dcBrowser client starts and the terminal's 3. Select drive C and press appears. home page appears.
The home page is the starting screen of the application. If you need to restart the home page or if communication between the client and the dcBrowser gateway is disconnected, press Ctrlto restart communications with the dcBrowser gateway, or to return to the home page.
/
Running the dcBrowser Client When you are running your HTML application, follow these guidelines: •
Use the cursor keys or Tab key to navigate from field to field.
•
Use the device’s scanner and keyboard to enter data.
3-7
Page 52
Data Collection Browser Client User’s Guidelk
•
Use auto-transmit fields to cause a screen to automatically transmit when data is scanned into a specific field. For help, see “Using Auto-Transmit Fields” in Chapter 2.
•
Access the hypertext links by pressing the appropriate function key.
•
Press Ctrlto restart communications with the dcBrowser gateway if you want to restart at the home page.
/
If you reboot the terminal, the terminal restarts the dcBrowser client when it finishes rebooting. The following table lists special dcBrowser client key combinations that you may want to use while you are running your HTML application. Client Keys
Description
Ctrl-
Clear screen
" Ctrl-# Ctrl-/ Ctrl-Ctrl-3 Ctrl-6 Ctrl-; Ctrl-X Ctrl-: Ctrl-V
3-8
Toggle Debug mode Restart communications with dcBrowser gateway and return to home page Ping the dcBrowser gateway Toggle Timing mode Refresh screen Decrease contrast Increase contrast Increase volume Decrease volume