The text of a manual · part 10 of 14
Data Collection Browser Client User's Guide: Chapter 6 - RT1700 and 6400 Devices
Pages 69 to 80 of 107, from Data Collection Browser Client User's Guide
The original document is the PDF (897 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6400
Page 69
6 RT1700 and 6400 Devices
Page 70
abc
Page 71
RT1700 and 6400 Devices
6
This chapter explains how to load and run the dcBrowser client on your 6400 device and how to use dcBrowser with the RT1700.
Overview Use this chapter to • use the dcBrowser gateway on the RT1700.
• verify that the dcBrowser client is loaded.
• load the dcBrowser client if it is not loaded.
• start the dcBrowser client.
• run the dcBrowser client.
Note: You can use the 6400 with either TCP/IP or WTP. Each protocol uses an .EXE file and an .INI file. The .EXE file is identical for each protocol; however, the .INI file settings are different for each protocol. Instructions for changing the .INI file settings are included in this chapter.
Using the dcBrowser Gateway on the RT1700 To use RT1700 devices with the dcBrowser gateway, you must configure the RT1700. To configure the RT1700 device •
Configure the RT1700 to run Native terminal emulation as described in the RT1700 Radio Data Terminal User’s Guide (Part No. 961-047-068). You must configure the RT1700 as a WTP device in the DCS 30X.
The RT1700 does not support highlighting and tab to anchors.
Verifying the dcBrowser Client Is Loaded If your 6400 came preloaded with the dcBrowser client, go to “Starting the dcBrowser Client” later in this chapter. To determine if you have the dcBrowser client loaded on your 6400 1. Type dir at the DOS prompt. A list of the files loaded on your 6400 appears. 2. Look for the following two files: •
N6400.EXE (the client program)
•
PSKNET.INI (the protocol parameter file)
6-3
Page 72
Data Collection Browser Client User’s Guide
If these files are not on your 6400, go to “Loading the dcBrowser Client” in the next section. If these files are on your 6400, go to “Starting the dcBrowser Client” later in this chapter.
Loading the dcBrowser Client This section explains how to load the dcBrowser client on your 6400 device. You can load the dcBrowser client in one of the following ways: •
Use TFTP.
•
Use Intersvr/Interlnk.
•
Use the Windows-based FileCopy utility.
To use the dcBrowser client on the 6400, you must use one of the following two configurations: 1. A 6400 with the original terminal emulation that includes Native terminal emulation. Note: Some dcBrowser client features are limited when used with this configuration, and if you have a WTP network, you will need to use a DCS 30X. 2. The TCP/IP bundle for either the WLI Forum OpenAir radio or 802.11b radio. You can order your 6400 to come with either configuration, or you can purchase the bundles separately and load them. For help loading the bundles, see the documentation that came with the bundle and the 6400 Hand-Held Computer User’s Manual (Part No. 961-047-093). For the second configuration, you need to copy the files in the following table to drive C on the 6400. For a standard installation of the DCS 30X or software only dcBrowser gateway, the files are in INTERMEC\DCBROWSER\CLIENT\I6400.
6-4
File
Description
IMDCB.INI
This file provides commands needed to configure the scanner symbology. The file provides some example symbologies, but you can edit different symbologies using the reader configuration commands. For help using reader configuration commands, see the 6400 Application Development Tools System Manual (Part No. 070130).
N6400.EXE
This file is the dcBrowser client for the 6400.
64SCN7A.EXE
This file is the utility for accessing the scanner and runs as a terminateand-stay resident (TSR) program. If you use a scanner on the 6400, run this file before running N6400.EXE.
Page 73
RT1700 and 6400 Devices
6
Required Files for the dcBrowser Client (continued) File
Description
RL2PCM.COM
This file is a radio driver. If you are using OpenAir TCP/IP, copy this file to the 6400. After you reboot the 6400, this file automatically runs.
PSKNET.INI
This file defines the host IP address. You need to edit this file to point to the server running the dcBrowser gateway.
ITC64XFR.EXE
This file is a utility that you can use to transfer files without using Interlnk/Intersvr. You can use ITC64XFR.EXE in conjunction with FileCopy by setting up FileCopy to transfer a file using XMODEM 1K. In FileCopy, you must set the serial port to the following settings: • • • • • • • • •
Baud rate = 19200 Parity = None Data bits = 8 Stop bits = 1 SOM = \x02 EOM = \x03 LRC = Disabled Handshake = Disabled Commands = Enabled, no TMF
Initially you can move these files to the 6400 using only TFTP or Interlnk/Intersvr. You can use FileCopy after you move ITC64XFR.EXE.
Setting the Network Configuration Before you can run the dcBrowser client, you must set the 6400’s network configuration using chgparms. To set the network configuration using chgparms 1. At a DOS prompt on your 6400, type chgparms and press Enter. A menu appears. For help getting to a DOS prompt, see the 6400 Hand-Held Computer User’s Guide. 2. Choose 1 to set up the 6400’s IP address and network configuration, which your network administrator provides. For more information about setting the 6400’s IP address and network configuration, see the 6400 Hand-Held Computer User’s Guide. 3. Choose 4 to set up the access point security ID, which your network administrator provides. For more information on the access point’s security ID, see the user’s manual for the access point.
6-5
Page 74
Data Collection Browser Client User’s Guide
Transferring Files Using TFTP Before you can transfer files using TFTP, you need to set up the device IP address and establish a radio connection. For help see the 6400 Hand-Held Computer User’s Manual. You can use TFTP with your 6400 on Windows 2000, Windows NT, and Windows XP. To set up the 6400 for TFTP •
At a DOS prompt on the 6400, type tftp serve and press Enter.
To transfer files 1. Make sure you have the IP address for the 6400 and that the 6400 is communicating through an access point to your PC. 2. Start a DOS session on your PC. 3. Type tftp -i host put filename c:\filename where:
-i specifies binary image transfer mode (also called octet). In binary image transfer mode, the file is transferred byte by byte. Use this mode to transfer files.
host is the IP address for the 6400.
put indicates that the file is going to the 6400. To transfer files from the 6400 to the PC, replace put with get.
filename is the name of the file that you want to transfer.
c is the destination drive on the 6400.
4. Press Enter.
Transferring Files Using Interlnk/Intersvr To transfer files using Interlnk/Intersvr, your PC must be running Interlnk, which is part of MS-DOS. Note: Interlnk/Intersvr are not available in Windows NT and Windows 2000. Use TFTP to transfer files. To transfer files 1. Load Interlnk as a device driver in your CONFIG.SYS file on the PC by inserting the following statement at the end of CONFIG.SYS: DEVICE=C:\DOS\INTERLNK.EXE /DRIVES:2
6-6
Page 75
RT1700 and 6400 Devices
6
The previous statement assumes that MS-DOS is located in the C:\DOS directory on your PC. The DRIVES:2 parameter allows mapping of two drives from the 6400. 2. Reboot the PC. 3. Connect the serial port on the 6400 to the serial port on the PC. For help, see the 6400 Hand-Held Computer User’s Manual. 4. Press Ctrl-Alt-Del on the 6400 and then press Alt. The boot selection menu appears. Note: If Ctrl-Alt-Del does not boot the 6400, press Enter-Enter-Blue Shift-Yellow Shift at the same time. 5. Select 5. The 6400 boots to the DOS prompt. 6. At the DOS prompt on the PC, type interlnk and press Enter. The following chart appears: C:\WIN>interlnk Port=COM2 This Computer
Other Computer
(Client)
(Server)
--------------
------------------------
F:
equals
A:
G:
equals
C:
7. Copy the files to Drive G. 8. Set the network configuration. For help, see “Setting the Network Configuration” earlier in this chapter.
6-7
Page 76
Data Collection Browser Client User’s Guide
Configuring the Host Connection You configure the host connection in the PSKNET.INI file, which you download to the 6400. This file determines which protocol is used (WTP or TCP/IP) and the connection information for that protocol. To edit PSKNET.INI 1. Complete the PSKNET.INI file for each 6400. A sample of the PSKNET.INI file is shown below. For WTP
For TCP/IP
[net use] loaded-wtp-stack = true loaded-tcp-stack = false
[net use] loaded-wtp-stack = false loaded-tcp-stack = true
[wtp addresses] host-name = DCS1 domain-lanID = 2 terminal-number = 2
[pctcp addresses] server-ip = IP of gateway port-use = 4055*
* do not change this value
Note: The PSKNET.INI file contains unique information for each 6400. You must complete the PSKNET.INI file for each 6400. Set [net use] section to match the protocol you are using. 2. Set the [wtp addresses] or [pctcp addresses] section with the correct values for the system configuration. Note: For WTP, the host-name and domain-lanID may be the same for several or all of the terminals in a configuration. The host-name is a unique name that you configure through your DCS 30X. The domain-lanID is a unique name that you configure through your access point software. Each device has a unique terminal number that corresponds to the device number on the dcBrowser Device Mapping Configuration screen. When configuring your devices, be sure to select WTP for the device connection type.
Transferring Files Using FileCopy The FileCopy utility ships on the dcBrowser Client CD. When you installed the simulator, this utility was loaded in /INTERMEC/TOOLS/FILECOPY on your PC. To load the dcBrowser client using FileCopy 1. On your PC, start FileCopy. 2. Click the down arrow for the Terminal Type field and select 6400.
6-8
Page 77
RT1700 and 6400 Devices
Terminal Type Field
Intermec FileCopy Utility
Terminal Type: |50xx FileCopy | setup |
PC filename and pat
Terminal filename and path:
ha Delete Terminal File
Download
|
[ Run program
Upload
|" After Upload
Delete How
3. Click the COM Port Setup tab.
Intermec FileCopy Utility
| Exit Help |
Terminal Type: e400
FileCopy COM Port Setup | Serial Setup | Communications Parameters
PCCOMPort:, [Com fea] TRAKKER COM1 ea] COM Port:
Communication |Configurable a Protocol:
File Transfer | aaa» Protocol:
Baud Rate: 1 9200 a
Parity Types:
( Hone C Odd f Even
About ul
Beles
Data Bits:
ond
Stop Bits:
4
Exit Help |
C8 C2 About |
Page 78
Data Collection Browser Client User’s Guide
4. Set the following port settings: •
PC COM Port = the COM port that the 6400 is connected to
•
TRAKKER COM Port = COM1
•
Communication Protocol = Configurable
•
File Transfer Protocol = XMODEM
•
Baud Rate = 6400’s baud rate. To set the 6400’s baud rate, type Mode Com1 Baud=baudrate at the 6400’s DOS prompt where baudrate is the new baud rate.
5. Click the FileCopy tab.
6. Under PC filename and path, click Browse and select the path to the N6400.EXE. For a standard installation, N6400.EXE should be in INTERMEC\DCBROWSER\CLIENT\I6400. 7. Under Terminal filename and path, type c:\n6400.exe. 8. Click Download. On the PC, a status window appears showing the progress of the transfer.
6-10
Page 79
RT1700 and 6400 Devices
6
Starting the dcBrowser Client After you have loaded and configured the dcBrowser client, you are ready to start the client. To start the dcBrowser client on the 6400 1. Type loadscan. Two TSR programs run and then the DOS prompt returns. 2. Type n6400. The following text appears: Thin client for dcBrowser
Then the Web page for the device appears.
Running the dcBrowser Client When you are running your HTML application, follow these guidelines: •
Use the cursor keys to navigate from field to field.
•
Use the device’s scanner or keyboard to enter data.
•
Use auto-transmit fields with scan-ahead data and type-ahead data. For help, see “Using Auto-Transmit Fields” in Chapter 2.
•
Access the hypertext links by pressing the appropriate function key.
•
Press and release Ctrl, and then press to restart communications with the gateway if your device has been inactive for a period of time.
4
If you reboot the device, the device restarts the dcBrowser client when it finishes rebooting. This table lists special dcBrowser client key combinations that you may want to use while you are running your HTML application. Client Keys
Description
Ctrl-
Toggle Debug mode
Ctrl-
Restart communications with dcBrowser gateway
Ctrl-
Ping the dcBrowser gateway
Ctrl-
Toggle Timing mode
Ctrl-
Refresh screen
Ctrl-
Exits the dcBrowser client
# 4 3 6 7
6-11
Page 80
blank