The text of a manual · part 11 of 14
Data Collection Browser Client User's Guide: Chapter 7 - 700 Series Mobile Computer
Pages 81 to 88 of 107, from Data Collection Browser Client User's Guide
The original document is the PDF (897 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6400
Page 81
7 700 Series Mobile Computer
Page 82
abc
Page 83
700 Series Mobile Computer
7
This chapter explains how to load and run the dcBrowser client on your 700 Series Mobile Computer.
Overview Use this chapter to • configure and start the dcBrowser client.
• connect to the dcBrowser gateway.
• run the dcBrowser client.
Configuring and Starting the dcBrowser Client You can use the Application Manager component of Unit Manager for PlanNET or ActiveSync to load the dcBrowser client on your 700. •
Use File Manager to load applications on your 700 over a network.
•
Use ActiveSync to establish a serial connection between your desktop PC and a 700. You can establish a serial link using a 700 Series Single Dock, a serial cable, or an ActiveSync cable. For more information, contact your Intermec sales representative.
For more information about Application Manager, see the online help for Unit Manager for PlanNET. For more information about ActiveSync, see “Using ActiveSync” later in this chapter. Note: If your 700 has firmware v1.05 or higher, you need to load ITC50.DLL along with the dcBrowser client. You can find this file on the dcBrowser CD in Intermec\dcBrowser\client\I700. Before you can run the dcBrowser client, you need to configure TCP/IP on the 700. You also need to find the IP address and port number for the PC or DCS 30X that the dcBrowser gateway is running on. To configure TCP/IP on the 700 1. From the Start menu, select Settings. The Control Panel appears. 2. Tap the Connections tab. 3. Tap Network. 4. Under Adapters installed, tap the Ethernet card driver you are using for your network. 5. If you are using a dynamic host configuration protocol (DHCP) server, select Use server-assigned IP address.
7-3
Page 84
Data Collection Browser Client User’s Guide
If you are not using a DHCP server, select Use specific IP address and enter the IP address, subnet mask, and default gateway for your 700. Your network administrator should provide you with this information. 6. Tap OK. A message appears; tap OK. 7. Tap the System tab and tap Wireless Network. 8. Choose Access Point and tap Edit Profile. 9. In the Network Name field, enter the network name. 10. Tap OK twice. 11. To exit the Control Panel, select another application from the Start menu. To start dcBrowser for the first time on the 700 1. From the Start menu, select dcb700. A splash screen appears showing the dcBrowser title and version number. 2. To set the IP and port number of the dcBrowser gateway, tap (Press Here for Setup). 3. Press Enter to save your configuration.
Using ActiveSync You can use ActiveSync to establish a connection between your desktop PC and a 700 for file viewing and synchronization, remote debugging, and other device management activities. Caution The 700 should be powered by an AC power source when you use ActiveSync. Conseil Il faut alimenter le 700 par une source de courant AC lors de l’exécution du ActiveSync. When you perform a cold boot, you lose the configuration settings that enable a connection to ActiveSync. IrDA, RF, or Ethernet settings remain after a cold boot.
Installing ActiveSync Instructions for using ActiveSync are provided with the product. ActiveSync can be downloaded from the Microsoft Web site at www.microsoft.com/mobile/pocketpc /default.asp.
7-4
Page 85
700 Series Mobile Computer
7
To establish a partnership between a 700 and a desktop PC, you must use a serial cable, an ActiveSync cable, or a 700 Series Single Dock. To order a cable or dock, contact your Intermec sales representative. To install ActiveSync and establish a partnership with your 700 1. Connect the 700 to your desktop PC using a serial cable, an ActiveSync cable, or a 700 Series Single Dock. For help, see the documentation that came with your cable or dock. 2. Download ActiveSync from the Microsoft Web site and follow the onscreen instructions for installing it on your desktop PC. When this process is complete, the Get Connected dialog box appears.
3. Select the Next button on the desktop PC. The 700 should shortly be communicating with your desktop PC. Follow the onscreen instructions for establishing a partnership. When the partnership has been established, the device name of your 700 appears in the ActiveSync window on your desktop PC:
7-5
Page 86
Data Collection Browser Client User’s Guide
Now that the partnership has been established, all future connects and disconnects will be handled through ActiveSync. Note: On the 700, PC Connection sets a baud rate of 19200 when first establishing an ActiveSync partnership. If you change the 700 baud rate setting after a partnership has been established, it may take several connection attempts before ActiveSync can automatically match the desktop PC to the new baud rate. After the connection is made at the new baud rate, this becomes the default ActiveSync baud rate.
Reconnecting to Your Desktop PC After you have created a partnership using ActiveSync, use it to re-establish the connection between the 700 and your desktop PC. To reconnect a 700 to a desktop PC using ActiveSync 1. If you are using a batch 700, connect it to your desktop PC through a serial cable, an ActiveSync cable, or a 700 Series Single Dock. If ActiveSync is set to automatically connect with devices, the 700 immediately establishes a connection and the 700 ActiveSync window appears on your desktop PC. If you are using an RF 700, be sure it is within range of an access point. 2. From the Start menu, tap Programs and then Connections. 3. Tap ActiveSync. The ActiveSync dialog box appears.
4. Tap the down arrow by the Method field and choose a connection method: •
Choose Infrared if you are using the IrDA port.
•
Choose Network Connection if you are using a radio.
•
Choose one of the default baud rates to connect serially. Choose the baud rate that your desktop PC uses.
5. Tap the down arrow by the Connect to field and choose your desktop PC or another device with which you want to establish the connection.
7-6
Page 87
700 Series Mobile Computer
7
6. Tap Connect. The Connecting to Desktop message box appears. When ActiveSync has established the connection, the Connection Status dialog box appears.
To disconnect a 700 using ActiveSync •
Tap Disconnect in the Connection Status dialog box. The 700 disconnects itself from the desktop PC and closes the Connection Status dialog box.
Connecting to the dcBrowser Gateway After you have loaded and configured the dcBrowser client on your 700, change the following parameters in the INI file for the dcBrowser gateway: Parameter
Change Value to
INPUT_HIGHLIGHT
INVERSE
ANCHOR_HIGHLIGHT
UNDERLINE
SUBMIT_HIGHLIGHT
UNDERLINE
TAB_TO_SUBMIT
TRUE
TAB_TO_ANCHOR
TRUE
For the software only dcBrowser gateway, the INI file is DCB.INI. For the dcBrowser on a DCS 30X, the INI file is WBS.INI. To change the INI parameters 1. Open the INI file in a text editor such as Notepad. 2. Change the parameters to the required values. 3. Save the changes to the INI file. 4. Exit the text editor. You are now ready to start the dcBrowser client and connect to the gateway.
7-7
Page 88
Data Collection Browser Client User’s Guide
To start the dcBrowser client on your 700 •
From the Start menu, select dcb700.
Running the dcBrowser Client Note: You need to use the soft keyboard for the key sequences that include the Ctrl key. When you are running your HTML application, follow these guidelines: •
Use the cursor keys, Tab key, or stylus to navigate from field to field.
•
Use the device’s scanner or keyboard to enter data.
•
Use auto-transmit fields to simplify data input. For help, see “Using Auto-Transmit Fields” in Chapter 2.
•
Use the stylus to access the hypertext links or input buttons.
•
Press Ctrl-
/ to return to the home page.
These tables list special dcBrowser client key combinations that you may want to use while you are running your HTML application. The following table lists key combinations for the virtual keyboard. Virtual Keys
Description
Ctrl-
Clear screen
Ctrl-
Ping the dcBrowser gateway
Ctrl-
Toggle Timing mode
Ctrl-
Refresh screen
Ctrl-
Increase volume
Ctrl-
Decrease volume
" 3 6 :
V
This table lists key combinations for keys on the 700. Client Keys
Description
Gold-7
Restart communications with dcBrowser gateway
Gold-9
Exits the dcBrowser client
To open the IP configuration screen, tap “Press Here for Setup” only at the 700 splash screen.