Intermec's two-page quick start guide (P/N 072384-003) for the Trakker Antares 2475 vehicle-mount terminal. It lists the main features and specifications, then walks through setting the time and date, the network and radio parameters, and the TE 2000 terminal emulation type.
- Device
- Programmable vehicle-mount data collection terminal for RF networks, running client/server or terminal emulation applications p. 1
- Radio
- IEEE 802.11b radio as shipped, Wi-Fi certified; 802.1x TTLS, 802.1x LEAP or WEP security p. 1, 2
- Ports
- Scanner port; serial port for RS-232 communications p. 1
- Memory
- 512K RAM for applications programmed in Microsoft C; 750K flash drive for user applications and files p. 1
- Power
- 10V to 36 VDC or 15V to 96 VDC universal power supply (operating with external power supply) p. 1
- Memory backup
- Rechargeable NiCad 700 mA battery pack p. 1
- Operating temperature
- -10°C to +50°C (4°F to +122°F) p. 1
- Storage temperature
- -20°C to +60°C (-4°F to +140°F) p. 1
- Battery charging
- Backup battery charges at 0°C to +40°C (+32°F to +104°F) p. 1
- Size and weight
- Height 26.5 cm (10.4 in); depth 9.7 cm (3.8 in); weight 4.7 kg (10.5 lb) p. 1
- Humidity
- 0 to 95% non-condensing p. 1
- Networks
- UDP Plus or WTP through access points and an Intermec Gateway or DCS 30X; TCP/IP directly through access points p. 2
- Terminal emulation
- TE 2000 VT/ANSI by default; can be changed to TE 2000 5250 or TE 2000 3270 p. 2
- Related manuals
- 2475 User's Manual P/N 072383; 2400 Family System Manual P/N 071389; 2475 Installation Instructions P/N 072512 p. 1, 2
What this manual walks you through
- Learning the color-coded keypad p. 2
- Setting the time and date p. 2
- Configuring the primary network parameters p. 2
- Configuring the advanced network parameters for UDP Plus or TCP/IP p. 2
- Configuring the radio parameters and 802.1x or WEP security p. 2
- Choosing the TE 2000 terminal emulation configuration p. 2
Good to know
- All RF devices that talk to each other must contain the same radios. p. 2
- The guide states an IP54 environmental rating. p. 1
- Keep the box and shipping material in case the terminal must be shipped or stored. p. 1
Questions this manual answers
What power does the Intermec 2475 need?
With an external power supply it runs on 10V to 36 VDC or 15V to 96 VDC (universal power supply). p. 1
What radio does the Trakker Antares 2475 have?
It ships with an IEEE 802.11b radio, Wi-Fi certified for use with other 802.11b wireless LAN devices. p. 1
How much memory does the 2475 have?
512K RAM for applications programmed in Microsoft C and a 750K flash drive for user applications and files. p. 1
What is the operating temperature of the 2475?
-10°C to +50°C as printed (4°F to +122°F); storage is -20°C to +60°C. p. 1
Which terminal emulation does the 2475 use by default?
TE 2000 VT/ANSI; it can be changed to TE 2000 5250 or 3270 from the TE 2000 main menu. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
This product with the 802.1x security option includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/). This product with the 802.1x security option includes cryptographic software written by Eric Young (eay@cryptsoft.com). 2475Q007.eps Del
21 R4 LBF6bkspJ O I U Y TR E&PH G F DS A*KV C X Z Caps7
- N
ta9 8CtrlM F7I/O%$F8F165LF9F2#@f Fn FnF10>3Ins< Ente rfF5 F4 F3
This guide describes how to set basic parameters to start using the 2475. For a list of additional documents you may need to configure the 2475 for your data collection network, see “Where to Go From Here” later in this guide.
.0 -+., /\?W
Trakker Antares 2475 terminals with an IEEE 802.11b radio installed are Wi-Fi certified for interoperability with other 802.11b wireless LAN devices.
Q esc
Trakker Antares® 2475 Vehicle-Mount Terminal Quick Start Guide
- 512K RAM reserved for applications programmed in Microsoft C
- 750K flash drive to store user applications and files
- IEEE 802.11b radio for RF communications
- Adjustable terminal mounting bracket
- Scanner port to attach a scanner
- Serial port for RS-232 communications with other RS-232 devices The 2475 is designed to make data collection easy and includes these features: The Trakker Antares® 2475 is a programmable vehicle-mount data collection terminal that can communicate in an RF network. You can use the 2475 to run client/server applications or terminal emulation applications.
When you remove the terminal from its box, save the box and shipping material in case you need to ship or store the terminal.
About the 2475
Out of the Box
2475 Features 27.1 cm (10.7 in)
- Height
- 26.5 cm (10.4 in)
- Depth
- 9.7 cm (3.8 in)
- Weight
- 4.7 kg (10.5 lb)
Where to Go From Here Quick Start Guide
Now that your new terminal is working, you may need additional information to use the 2475 in your data collection system:
Physical Dimensions Length:
The terminal shipping box contains:
Specifications
- The Trakker Antares 2475 Vehicle-Mount Terminal User’s Manual (P/N 072383) contains all the information necessary to configure, operate, and troubleshoot the 2475. The user’s manual comes with the Trakker Antares 2400 Family System Manual (P/N 071389), which contains detailed information about configuring, operating, and programming all terminals in the 2400 Family.
- These TE 2000 guides provide additional help using terminal emulation: TE 2000 5250
Power Specifications Operating (with external power supply):
10V to 36 VDC or 15V to 96 VDC universal power supply
- Memory Backup
- Rechargeable NiCad 700 mA battery pack
- Electrical rating
- x 12V, 750 mA
Temperature and Environmental Specifications Operating the terminal:
-10°C to +50°C (4°F to +122°F)
- Storing the terminal
- -20°C to +60°C (-4°F to +140°F)
- Charging the backup battery
- 0°C to +40°C (+32°F to +104°F)
- Relative humidity
- 0 to 95% non-condensing
- Environmental rating
- IP54
Terminal Emulation Programmer’s Guide (P/N 977-055-004), TE 2000 3270 Terminal Emulation Programmer’s Guide (P/N 977-055-003), and TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide (P/N 977-055-005).
- For additional help using dcBrowser, see the online help that ships with the dcBrowser gateway software, or see the Data Collection Browser Client User’s Guide (P/N 070011).
The Intermec web site at www.intermec.com provides our current manuals as PDF files for you to download. To order accessories and printed documentation, contact your local Intermec representative.
Trakker Antares 2475 Vehicle-Mount Terminal Quick Start Guide
*072384-003* P/N 072384-003
6001 36th Avenue West Everett, WA 98203 U.S.A. www.intermec.com © 2004 Intermec Technologies Corp. All Rights Reserved
Trakker Antares® 2475 Vehicle-Mount Terminal
Heading 1
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Trakker Antares 2475 Vehicle-Mount Terminal Quick Start Guide
1 Prepare to Use the Terminal
2 Set the Time and Date
You can use the keypad to access the TRAKKER Antares 2400 Menu System and set the time and date.
Before you can start using the 2475 you need to:
- Install the terminal.
- Charge the backup battery.
- Learn how to use the keypad.
1
Press the œ key. The terminal runs POST (power-on self test), and then the Boot Menu appears. If you ordered a TE 2000 application, you must first configure the TE parameters. For help, see the appropriate TE 2000 guide.
2 3
Press 1 to boot the terminal and initialize the firmware. Press ) ; 2 4 8 to access the TRAKKER Antares 2400 Menu System. The Main Menu appears.
Learning How to Use the Keypad Characters, symbols, and functions are printed in four places on or above the keys. The keypad overlays are also color-coded to make it easier to remember key combinations.
Color on Overlay
Middle of the key or centered above the key
To Type the Character Press the key.
Orange
Press the orange ) key, and then press the key.
Centered above a numeric key
Green
Press the green ? key, and then press the key.
Right side above the key
Blue
Press the blue ( key, and then press the key.
You can also use the arrow keys to move around an application screen. To move up or down the screen, press ¥ or †. To move left or right, press – or ª.
the Advanced Network 4 Configure Parameters From the Main Menu, choose Configuration Menu > Communications Menu > Advanced Network. The Advanced Network screen appears.
2
For a UDP Plus or TCP/IP network only, set the parameters on the Advanced Network screen:
- Set Network Port.
- For an Intermec Gateway, DCS 30X, or host on a different subnetwork, set Default Router and Subnet Mask.
ADVANCED
NETWORK
Loopback: Disabled Network Port: 05555 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 Controllr Connect Chk Send Timer:0035 sec Recv Timer:0060 sec Retries: 07
From the TRAKKER Antares 2400 Main Menu, choose Configuration Menu > Communications Menu > Primary Network. The Primary Network screen appears.
2
Set these parameters on the Primary Network screen:
- Make sure that 2.4 GHz (OpenAir radio) or 802.11 DS (802.11b radio) appears in
5
Type the current time in the format HH:MM:SS (hours:minutes:seconds) and press >.
- For UDP Plus, set Controller IP Address, or for TCP/IP, set Host IP Address.
- For a non-DHCP environment only, set Terminal IP Address.
Type the current date in the format YYYY/MM/ DD (year/month/day) and press >. Press \ to save the changes and exit the Time and Date screen.
7
Press d twice and choose Yes or OK to save your changes.
8TIMEAND
Current time 12:00:00 New time: 12:39:00
is
Current date is 2001/01/01 New date YYYY/MM/DD:
CANCELOKthe Activate field.DATE2475Q004.eps
UDP Plus or WTP Primary Network
TCP/IP Primary Network
PRIMARY NETWORK Activate: Disabled Controller IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
PRIMARY NETWORK Activate: Disabled Host IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
If you are using the Wavelink Avalanche client management system, you can quickly configure the parameters for your terminal. For help, see Chapter 2, “Configuring and Managing the Terminals,” in the Trakker Antares 2400 Family System Manual (P/N 071389).
The 2475 communicates with a host computer in an RF network either through access points and the Intermec Gateway or DCS 30X, or directly through the access points. All RF devices that communicate with each other must contain the same radios. The terminal ships with the IEEE 802.11b radio.
To configure the radio parameters
1 2
From the Main Menu, choose Configuration Menu > Communications Menu > Radio. The Radio screen appears. Set these parameters on the Radio screen:
- For an IEEE 802.11b radio and 802.1x security, set Network Name. Scroll to the
802.1x TTLS or 802.1x LEAP security screen and set User Name and Password. The illustration below shows the 802.1x TTLS screen.
TCP/IP Advanced Network ADVANCED
1
Press † † ; to select the System Menu, and then press † † ; to select Set Time and Date.
5 Configure the Radio Parameters
1
To configure the primary network parameters
4
6
Left side above the key
UDP Plus Advanced Network
The 2475 communicates with a host computer either through access points and the Intermec Gateway or DCS 30X (UDP Plus or WTP network) or directly through the access points (TCP/IP network). You need to obtain most of these settings from your network administrator.
To set the time and date
For help installing the terminal and charging the backup battery, see the Trakker Antares 2475 Vehicle-Mount Terminal Installation Instructions (P/N 072512). For help learning how to use the keypad, continue with the next section.
Position on the Keypad
the Primary Network 3 Configure Parameters
NETWORK
- For an IEEE 802.11b radio without 802.1x security, set Network Name. Scroll to
Network Port: 00023 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 TCP/IP Maximum Transmit Timeout: 020 sec
the WEP security screen and set WEP Encryption, WEP Transmit Key, and at least one WEP Key.
802.1x Security 2475Q036.eps
802.1x UserTTLSWEP
- Encryption
- Disabled WEP
Transmit
anonymous Password: *** Server 1 Cert
- CN
- Key
- 2
- Server
- CN
- Key
- 3
- Key
- 4
- 2
Cert
- Key
- 6 Choosing Your TE 2000 Configuration
If you have a TE 2000 application, your terminal is configured for TE 2000 VT/ANSI by default. You may need to change the configuration to TE 2000 5250 or TE 2000 3270.
To change the TE 2000 configuration
1
On your terminal, press ( !. The TE 2000 main menu appears.
2
Select Set-up Parms and press ;. A password prompt appears.
3 4
Type C R 5 2 4 0 1 and press ;.
5
Select Protocol Opts, Data Stream, and then select the appropriate TE 2000 configuration. Save your changes by selecting Exit Menus from the TE 2000 main menu. Press Y , and type C R 5 2 4 0 1 at the Enter Password prompt.
Main 1) 2) 3) 4) 5) 6) 7)
Menu
Set-up Parms LCD Parms Tests Version Info Exit Menus More
2475Q006.eps
For information about using TE 2000 terminal emulation, see the appropriate TE 2000 guide listed in “Where to Go From Here” later in this guide.
WEP Security
- Name
- 2475Q003.eps
1Key 1: *****2475Q005.eps