Application Note: AdaptaScan Reader to a PLC-5 Using DH-485 Protocol with the 2760-RB Module and the 2760-SFC2 Protocol Cartridge
Manual12 pagesPDF 154 KB
Application note for connecting Allen-Bradley AdaptaScan 2755-SN3, -SN5 and -SN8 readers to a PLC-5 over DH-485 via a 2760-RB module.
Names · 5 models
The models it names
Accu-Sort 2755-SN3Decoded fixed-mount laser barcode scanner from$1,995.001 in stock
Accu-Sort 2755-SN5Decoded fixed-mount laser barcode scanner from$1,795.0025 in stock
Allen-Bradley 2755-SN5Decoded fixed-mount laser barcode scanner from$1,795.0054 in stock
Accu-Sort 2755-SN8Decoded fixed-mount laser barcode scanner from$1,995.009 in stock
Allen-Bradley 2755-SN8Decoded fixed-mount laser barcode scanner from$1,995.0014 in stock Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
An Allen-Bradley application note showing how to connect an AdaptaScan 2755-SN3, -SN5 or -SN8 bar code reader to a PLC-5 using DH-485 through a 2760-RB interface module with the 2760-SFC2 protocol cartridge. It lists the hardware and software needed and PLC-5 compatibility, gives DIP switch settings and 2760-RB configuration menu entries, shows the reader's serial port and message setup in the offline programmer, and includes a sample PLC-5 block transfer program and cable diagrams.
Its parts
- Overview
- Hardware Requirements
- Software Requirements
- Related Publications
- PLC 5 Compatibility
- Configuration
- Sample PLC Program
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
An Allen-Bradley application note (Publication 2755-2.64) on connecting an AdaptaScan 2755-SN3, -SN5 or -SN8 bar code reader to a PLC-5 processor over DH-485, through a 2760-RB interface module fitted with a 2760-SFC2 protocol cartridge. It gives the DIP switch settings, the 2760-RB terminal setup, the reader software settings, a sample block transfer ladder program and two cable pinouts.
- Document
- Application note, Publication 2755-2.64, 1996 p. 1, 12
- Readers covered
- AdaptaScan 2755-SN3, -SN5 and -SN8 p. 1
- Protocol cartridge
- 2760-SFC2 p. 1
- Reader connection
- Reader RS-485 port on the wiring base to Port 1 of the 2760-RB p. 11
- DH-485 speed
- 2760-RB set to 19,200 bits per second p. 5
- Reader software
- 2755-ASN Windows-Based Offline Program Software p. 2
- PLC software
- Bulletin 6200 development software; 1784-KT or equivalent card in the computer p. 1, 2
- RS-485 cable
- 2760-RB Port 1 (25-pin D male) A to TxA, B to TxB, GND 7 to GND on the reader terminal strip p. 11
- Terminal cable
- 2760-RB config port (25-pin D male) to dumb terminal (25-pin D female): 2 to 3, 3 to 2, 7 to 7 p. 11
- 2760-RB terminal setup
- 9600 baud, 8 data bits, 1 stop bit, no parity, no flow control p. 5
- Module placement
- 2760-RB in slot 0 of the 1771 chassis, next to the PLC p. 3
- Message trailer
- Carriage Return and Line Feed (Cr, Lf) p. 4
- Related manuals
- 2755-837 reader installation, 2755-838 configuration software, 2760-ND001 2760-RB, 2760-2.19 2760-SFC2 p. 2
What this manual walks you through
- Setting the PLC-5, chassis backplane and 2760-RB DIP switches p. 3
- Configuring the 2760-RB from a terminal emulator p. 5
- Setting the reader's serial port, DH-485 and message options in the offline software p. 6, 7, 8
- Sample PLC-5 block transfer read and write program p. 9
- Using a 2760-RB Revision H or above with a New Generation PLC-5 p. 10
- Building the terminal cable and the RS-485 cable p. 11
Good to know
- The reader settings shown are only part of the configuration a real application needs. p. 6
- With a 2760-RB Revision H or above and a New Generation PLC5 in a local rack, the PLC may miss the BRR bit; an Immediate Input rung placed just before the BTR rung ensures it is seen. p. 10
- The block transfer read must come before the block transfer write. p. 10
- On a New Generation PLC-5 (Series A, Rev. C or above only), set BT Compatibility Bit S26/4 in program mode. p. 2
Questions this manual answers
How do I connect an AdaptaScan reader to a PLC-5 over DH-485?
Wire the reader's RS-485 port to Port 1 of a 2760-RB interface module in the PLC-5's 1771 rack, with a 2760-SFC2 protocol cartridge fitted. p. 1, 3
What baud rate does the 2760-RB use for the AdaptaScan DH-485 link?
The configuration parameters set it to 19,200 bits per second. p. 5
What terminal settings configure the 2760-RB?
9600 baud, 8 data bits, 1 stop bit, no parity and no flow control, then send a break sequence to bring up the configuration menu. p. 5
How is the AdaptaScan RS-485 cable to the 2760-RB wired?
On the 2760-RB Port 1 25-pin D male connector, A goes to TxA, B to TxB and GND 7 to GND on the reader's RS-485 terminal strip. p. 11
What software configures the AdaptaScan reader?
The 2755-ASN Windows-Based Offline Program Software. p. 2