Page 1

Application Note

AdaptaScan Reader to a PLC-5 Using DH-485 Protocol with the 2760–RB Module and the 2760-SFC2 Protocol Cartridge Overview

The AdaptaScan-SN3, -SN5 or -SN8 bar code reader may be configured to communicate with the 2760-RB interface module via DH485 protocol, using the 2760-SFC2 protocol cartridge. This document includes cable diagrams and configuration information for the AdaptaScan readers. It also includes an example PLC-5 program which is needed to establish communication from the PLC to the 2760-RB.

Hardware Requirements

The following Allen-Bradley hardware is needed to use the procedure described in this application note:

• 2755-SN3, -SN5, or -SN8 AdaptaScan reader and related manuals.

• 2760-RB interface module in a 1771 rack with a processor

• 2760–SFC2 protocol cartridge • Personal computer or VT 100 type terminal to configure the 2760-RB

• Appropriate cables to program the PLC-5 and to configure the 2760-RB interface module and the AdaptaScan reader. Refer to hardware manuals for cable requirements.

• Catalog Number 1784-KT or equivalent card installed in the computer to enable you to program the PLC-5.

Publication 2755-2.64

Page 2

2

Software Requirements

The following Allen-Bradley software is needed to use the procedure described in this application note:

• Bulletin 6200 development software for the PLC-5, to run in the personal computer

• Terminal Emulation software for a personal computer, to configure the 2760-RB

• 2755-ASN Windows-Based Offline Program Software to configure the AdaptaScan reader

Related Publications

This document refers to the following publications, which should be available for reference while working through this application note: Publication Number

PLC 5 Compatibility

1785-XXX

User Manual for your PLC-5

6200-XXX

Programming Manual for your PLC-5

2755-837

AdaptaScan Bar Code Readers Installation Manual

2755-838

AdaptaScan Configuration Software User Manual

2760–ND001

2760–RB User Manual

2760-2.19

2760-SFC2 Protocol Cartridge Manual

Use the following table as a configuration guideline when using the examples shown in this document. 2760-RB In Use Series A, Rev. G or below Series A, Rev H or Above

Publication 2755-2.64

Title

PLC-5, -15, -25, etc.

Follow example PLC program as shown on page 9.

New Generation PLC-5 (Series A, Rev. C or above only) Set BT Compatibility Bit S26/4 while in program mode. Use example PLC program shown on page 9. Add ladder logic using IIN update of RB. BTR must be before ‘BTW. Refer to page 10.

Page 3

3

Configuration

The 2760-RB configuration example includes sample configuration screens and DIP switch settings needed to establish communication with the AdaptaScan reader via RS-232. Other 2760-RB configuration features not used here are also available. See Publication 2760-ND001. PLC-5 processor DIP switches Switch #

1

2

3

4

5

6

7

8

SW-1 on on on on on on on off

SW-2 off on on on on on on off

SW-3 on on off off

I/O chassis backplane DIP switches 1

2

3

4

5

6

7

8 off off off off off on off off

2760-RB module DIP switches Switch #

1

2

3

4

5

6

7

8

SW-1 off off off off off off off off

SW-2 off off off off off off off off

SW-3 off off off off

SW-4 off off on off

The 2760-RB module is placed in the 1771 chassis in slot 0 next to the PLC. For this application, note that the AdaptaScan reader communicates through port 1 on the 2760-RB. A 1771-ASB module can also be used to communicate with the 2760-RB module over the chassis back plane to Remote I/O. Protocol Cartridge (Catalog No. 2760-SFC2)

Flexible Interface Module (Catalog No. 2760-RB) ASCII (Dumb) Terminal DH-485 AdaptaScan Bar Code Reader

Publication 2755-2.64

Page 4

4

PLC-5 Program The sample ladder logic listing below instructs the PLC-5 to: Rung 2:0 – Read AdaptaScan data from the 2760-RB module.

Refer to your PLC-5 user manual for detailed information on using the PLC-5 programming software. The configuration screens for the 2760-RB should be entered exactly as shown. These parameters then need to be saved. Both the AdaptaScan reader and the 2760-RB are configured to send and recognize the Carriage Return (Cr), Line Feed (Lf) characters to identify a message. When the 2760–RB senses information entering Port 1, it will look for the Cr, Lf. When it sees these trailers, it will Block transfer read (BTR) the preceding bar code data into the PLC program.

Publication 2755-2.64

Page 5

5

Configuring the 2760-RB 1. Set all 2760-RB module DIP switches to Off. 2. Connect the smart cable to the Configuration port of the 2760-RB and the serial port of the computer. 3. Use the Terminal Emulator to send a “break sequence” to the 2760-RB: A. Set the baud rate to 9600, 8 data bits, 1 stop bit, no parity, no flow control, and either COM1 or COM2 depending on the smart cable connection. B. Program a function key to send the “break sequence” by using the ^$B command. C. Send the break sequence to call up the 2760-RB configuration menu. 4. Select menu item 3: Device port protocol names. Set to: PORT1=COPYRIGHT 1989 ALLEN-BRADLEY COMPANY INC. 2760-SFC2 LAN SERIES A REVISION B (YES/NO)=YES

5. Select menu item 21: Identification numbers. Select: RS485 LAN 2755-DM6 ASCII MODE 3, 0H (YES/NO)=YES

6. Select option 11: Configuration parameters. Set to: SLOT TIME (NO. CHARS) (DEC 0 ... 255) = 15 INTER-CHAR TIME (NO. CHARS) (DEC 0 ... 255) = 7 IDLE TIME (NO. CHARS) (DEC 0 ... 255) = 3 RETRIES (DEC 0 ... 255) = 3 19,200 BITS PER SECOND (YES/NO)=YES BCD NODE NUMBERS (ENABLE/DISABLE)= ENABLE BYTE SWAPPING (ENABLE/DISABLE)=ENABLE RECEIVE MATRIXING (ENABLE/DISABLE)=DISABLE MATRIX ADDRESS (HEX 0 ... FFFF) = 0 RE-ESTABLISH FREQUENCY (DEC 0 ... 255)=5 POLL FREQUENCY/DESTINATION [0] (HEX 0 ... FFFF)=5 POLL FREQUENCY/DESTINATION [1] (HEX 0 ... FFFF)=105 POLL FREQUENCY/DESTINATION [2] (HEX 0 ... FFFF)=5 POLL FREQUENCY/DESTINATION [3] (HEX 0 ... FFFF)=5

7. Verify that the 2760-RB is in rack 0, group 0 module 0. 8. Save the above configuration.

Publication 2755-2.64

Page 6

6

2755-SN3, -SN5, -SN8 AdaptaScan Reader Configuration The AdaptaScan Offline Programmer configuration shows only the screens needed to establish communication to the 2760-RB module. Other AdaptaScan configuration parameters (selecting a bar code symbology, trigger methods, etc.) are beyond the scope of this document. See the AdaptaScan Configuration Software user manual. An example configuration for the 2755-SNx AdaptaScan Reader is illustrated below. Important: The settings illustrated below represent only part of the configuration required for the AdaptaScan reader to work in a given application. Refer to the AdaptaScan Configuration Software user’s manual for complete details on how to configure the reader for your application. The Project dialog contains all the basic configuration options.

Publication 2755-2.64