Page 1 of Symbol Palm Terminal Scanner System Software Manual

Manual · Symbol

Symbol Palm Terminal Scanner System Software Manual

Manual168 pagesPDF 1.2 MB

Scan Manager SDK software manual for writing scan-aware applications on Symbol Palm terminals such as the SPT 1700 series.

Download the PDF1.2 MB

Names · 1 model

The models it names

Filed with · 3 models

Also filed with these models on the old site

Summary

What is in it

Symbol's software manual for the Scan Manager software development kit used to build scan-aware applications on Symbol Palm terminals, including the SPT 1700 series. It explains the Scan Manager shared library API, scanner commands, barcode parameter functions for Codabar, Code 32, Code 39, I 2 of 5, MSI Plessey and UPC/EAN, hardware parameter functions, power considerations, a sample scanning application, and 2-D scanning considerations, with ASCII and parameter appendices.

Its parts

  1. About This Guide
  2. Using the Scan Manager Shared Library
  3. Scanner Commands
  4. Barcode Parameter Functions
  5. Hardware Parameter Functions
  6. Power Considerations
  7. Sample Scanning Application
  8. 2-Dimensional Scanning Considerations

From the manual

Key facts from this manual

Each line names its page in the PDF.

Developer manual for the Scan Manager software development kit (SDK) of the Symbol Palm Terminal, written for the SPT 1500 and SPT 1700 series. It explains the Scan Manager shared library calls an application uses to run the scanner, set bar code and hardware parameters and handle decoded data, with a sample program. It also covers power handling, reading long 2-D PDF417 data and the default parameter values.

Read for this summary: pages 4 to 8, 11 to 19, 45 to 47, 97 to 99, 137 to 138, 153 to 157 and 165 to 168 of 168.

Document
Scan Manager SDK manual for writing scan-aware Symbol Palm Terminal applications p. 7
Development tools
CodeWarrior p. 7
Decoded data length
255 bytes; up to 3000 bytes on SPT 1700 models with 2-D scanning p. 153
Scan battery threshold
About 2.3 volts; below it scans fail and the scanner is disabled p. 137
Symbology functions
Codabar, Code 32, Code 39, I 2 of 5, MSI Plessey, UPC/EAN, plus general functions p. 47
Triggering modes
Level (default), Pulse or Host p. 165
Scan angle
Wide (default) or Narrow p. 168
Laser on time
3.0 seconds by default p. 165
Header files
ScanMgrDef.h, ScanMgrStruct.h and ScanMgr.h p. 11, 12
Sample programs
SScan and Scan Demo p. 11, 16
Status codes
STATUS_OK, NOT_SUPPORTED, COMMUNICATIONS_ERROR, BAD_PARAM, BATCH_ERROR, ERROR_UNDEFINED p. 18

What this manual walks you through

  • Opening, configuring, enabling and closing the scanner in an application p. 11, 13, 14, 15
  • Using the Scan Demo application to try scanner settings p. 16
  • Scanner commands: enabling scans, starting a decode, LED, beeps and aim mode p. 17, 19
  • Choosing which bar code types and lengths are decoded p. 45, 47
  • Setting scan angle, aim duration, triggering, beeps and redundancy p. 97, 99
  • Handling the low-battery event, sleep mode and backlight during scans p. 137, 138
  • Reading long 2-D PDF417 decode data p. 153, 154, 155, 156, 157
  • Default values of the scanner parameters p. 165, 166, 167, 168

Good to know

  • An application must call ScanCloseDecoder() when it ends, or system errors and unexpected results follow. p. 15
  • Parameter changes are only local until ScanCmdSendParams() sends them to the scanner. p. 15
  • Removing the batteries while a scan-aware application runs is not recommended and may give unpredictable results. p. 138
  • Applications should not open the IR Exchange Manager or HotSync port while the scanner is open. p. 138
  • An application that calls only ScanGetDecodedData() gets just the first 255 bytes of a long bar code. p. 157

Questions this manual answers

How does an SPT 1700 application read PDF417 data longer than 255 bytes?

It checks the extended data flag in the scanDecodeEvent and calls the extended decode data function added to the SDK, with a buffer of the given length. 2-D models return up to 3000 bytes. p. 153, 154

At what battery voltage does the Symbol Palm Terminal stop scanning?

Below about 2.3 volts a scan fails and the scanner is disabled, and the application should tell the user why. p. 137

What steps does a scanning application follow with the Scan Manager library?

Open the scanner, enable scanning by hardware or application trigger, handle decoded data or errors, then shut the scanner down. p. 11

Why do my scanner parameter changes not take effect?

Settings made with the Scan Manager functions stay local until the application calls ScanCmdSendParams(). p. 15

What development environment does the SPT 1700 scanner SDK assume?

The manual assumes the developer knows the CodeWarrior development environment. p. 7

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. About This Guide7
  2. Scan Manager Library API SDK Documentation7
    1. What This Guide Contains8
    2. Conventions Used in this Guide8
  3. Chapter 1 Using the Scan Manager Shared Library11
    1. Using the API11
    2. Using the Scan Demo Application16
  4. Chapter 2 Scanner Commands17
    1. Introduction17
    2. Returned Status Definitions18
    3. Scanner Commands19
  5. Chapter 3 Barcode Parameter Functions45
    1. Introduction45
    2. Returned Status Definitions46
    3. Barcode Types47
    4. Codabar Barcode Parameter Functions48
    5. Code 32 Barcode Parameter Functions53
    6. Code 39 Barcode Parameter Functions56
    7. General Barcode Parameter Functions61
    8. I 2 of 5 Barcode Parameter Functions74
    9. MSI Plessey Barcode Parameter Functions77
    10. UPC/EAN Barcode Parameter Functions82
  6. Chapter 4 Hardware Parameter Functions97
    1. Introduction97
    2. Returned Status Definitions98
    3. Hardware Parameter Functions99
  7. Chapter 5 Power Considerations137
    1. scanBatteryErrorEvent137
    2. Sudden Loss of Power137
    3. Backlighting138
    4. Other Power Notes138
  8. Chapter 6 Sample Scanning Application139
    1. Writing the Code139
  9. Chapter 7 2-Dimensional Scanning Considerations153
    1. Introduction153
    2. Issue153
    3. Solutions153
  10. Appendix A ASCII Equivalents159
  11. Appendix B Parameter Definitions165

From the PDF’s own bookmarks.

The whole text · 21 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. About This Guide7-10
  3. Chapter 1 Using the Scan Manager Shared Library11-16
  4. Chapter 2 Scanner Commands, pages 17 to 2617-26
  5. Chapter 2 Scanner Commands, pages 27 to 3627-36
  6. Chapter 2 Scanner Commands, pages 37 to 4437-44
  7. Chapter 3 Barcode Parameter Functions, pages 45 to 5345-53
  8. Chapter 3 Barcode Parameter Functions, pages 54 to 6254-62
  9. Chapter 3 Barcode Parameter Functions, pages 63 to 7163-71
  10. Chapter 3 Barcode Parameter Functions, pages 72 to 8072-80
  11. Chapter 3 Barcode Parameter Functions, pages 81 to 8981-89
  12. Chapter 3 Barcode Parameter Functions, pages 90 to 9690-96
  13. Chapter 4 Hardware Parameter Functions, pages 97 to 10697-106
  14. Chapter 4 Hardware Parameter Functions, pages 107 to 116107-116
  15. Chapter 4 Hardware Parameter Functions, pages 117 to 126117-126
  16. Chapter 4 Hardware Parameter Functions, pages 127 to 136127-136
  17. Pages 137 to 144137-144
  18. Pages 145 to 152145-152
  19. Chapter 7 2-Dimensional Scanning Considerations153-158
  20. Appendix A ASCII Equivalents159-164
  21. Appendix B Parameter Definitions165-168

The file

Revision and size

Part no.70E-35914-02
RevisionRevision A, April 2000
PublisherSymbol Technologies, Inc.
Pages168
PDF1.2 MB
TextText from the PDF itself.
70E-35914-02

The first pages · 3 of 168

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 168
Page 2
Page 2of 168
Page 3
Page 3of 168