The text of a manual · part 15 of 21
Symbol Palm Terminal Scanner System Software Manual: Chapter 4 Hardware Parameter Functions, pages 117 to 126
Pages 117 to 126 of 168, from Symbol Palm Terminal Scanner System Software Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol SPT-1700
Page 117
Hardware Parameter Functions
ScanSetBeepAfterGoodDecode Purpose Determines whether the unit is to beep after a good decode. Prototype int ScanSetBeepAfterGoodDecode ( Boolean bEnableBeep);
Parameters -> bEnableBeep
Must be one of the following values: True=ENABLE False=DISABLE
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments When bEnableBeep is disabled, the beep still operates during parameter menu scanning, and indicates error conditions.
See Also ScanGetBeepAfterGoodDecode
4-21
Page 118
Symbol Palm Terminal Scanner System Software Manual
ScanSetBeepDuration Purpose Sets the duration of the beep for the specified beep types. Prototype int ScanSetBeepDuration ( DurationType type, int beep_duration);
Parameters -> type
Must be one of the following values: DECODE SHORT MEDIUM LONG
-> beep_duration
A numeric beep length in milliseconds (ms).
Returned Status STATUS_OK If an error occurs, the returned status is: BAD_PARAM
Comments Default durations are: Decode Short Medium Long
90 ms 70 ms 90 ms 240 ms
The acceptable range for any of these durations is 0 to 10,000 ms.
See Also ScanGetBeepDuration
4-22
Page 119
Hardware Parameter Functions
ScanSetBeepFrequency Purpose Sets the frequency of the beeper for the specified beep types. Prototype int ScanSetBeepFrequency ( FrequencyType type, int beep_freq);
Parameters -> type
Must be one of the following values: DECODE FREQUENCY LOW FREQUENCY MEDIUM FREQUENCY HIGH FREQUENCY
-> beep_freq
A numeric beep frequency in hertz (Hz).
Returned Status STATUS_OK If an error occurs, the returned status is: BAD_PARAM
Comments Default frequencies are: Decode frequency Low frequency Medium frequency High frequency
3000 Hz 1500 Hz 3000 Hz 7500 Hz
The acceptable range for any of these frequencies is 0 to 15,000 Hz.
See Also ScanGetBeepFrequency
4-23
Page 120
Symbol Palm Terminal Scanner System Software Manual
ScanSetBidirectionalRedundancy Purpose Requires that a barcode be successfully scanned in both directions before being decoded.
Prototype int ScanSetBidirectionalRedundancy ( Word redundancy);
Parameters -> redundancy
Must be one of the following values: ENABLE DISABLE
Returned Status
STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments This parameter is only valid when the ScanSetLinearCodeTypeSecurityLevel function call has been enabled.
See Also ScanGetBidirectionalRedundancy
4-24
Page 121
Hardware Parameter Functions
ScanSetDecodeLedOnTime Purpose Sets the amount of time the LED will be turned on when a successful scan is performcd.
Prototype int ScanSetDecodeLedOnTime ( Word led_on_time);
Parameters -> led_on_time
Must be an integer in the range [0...99], representing a time period of 0.0 to 9.9 seconds.
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments If a value of 0 is set for led_on_time, the LED will not be turned on. The led_on_time parameter is programmable in 0.1-second increments.
See Also ScanGetDecodeLedOnTime
4-25
Page 122
Symbol Palm Terminal Scanner System Software Manual
ScanSetLaserOnTime Purpose Sets the maximum scanner processing time to be allowed during a scan.
Prototype int ScanSetLaserOnTime ( Word laser_on_time);
Parameters -> laser_on_time
Must be an integer in the range [5...99], representing a time period of 0.5 to 9.9 seconds.
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments Your application should use the hardware trigger, instead of the ScanCmdStartDecode command, to initiate a scan. However, if the scanner was previously set to laser pointer mode by the ScanCmdAimOn command and the laser is activated by the ScanCmdStartDecode command, the laser remains on for laser_on_time x 10 seconds. The laser_on_time parameter is programmable in 0.1-second increments.
See Also ScanGetLaserOnTime
4-26
Page 123
Hardware Parameter Functions
ScanSetLinearCodeTypeSecurityLevel Purpose Selects the number of times the barcode is to be scanned before being decoded.
Prototype int ScanSetLinearCodeTypeSecurityLevel ( Word security_level);
Parameters -> security_level
Must be one of the following values: SECURITY_LEVEL1 SECURITY_LEVEL2 SECURITY_LEVEL3 SECURITY_LEVEL4
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments Security levels determine the number of times linear barcodes (such as Code 39 or I 2 of 5) are scanned before being decoded. Security levels do not apply to code 128 function calls. Higher security levels are needed for decreasing barcode quality. As security levels increase, the scanner’s aggressiveness decreases, so be sure to choose only that level of security necessary for any given application.
4-27
Page 124
Symbol Palm Terminal Scanner System Software Manual
Linear Security Level 1: The following code types must be successfully read twice before being decoded: CODE TYPE
LENGTH
Codabar
All
MSI Plessey
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
Linear Security Level 2: The following code types must be successfully read twice before being decoded: Code Type
Length
All
All
Linear Security Level 3: Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times: Code Type
Length
MSI Plessey
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
Linear Security Level 4: The following code types must be successfully read three times before being decoded: Code Type
Length
All
All
See Also ScanGetLinearCodeTypeSecurityLevel
4-28
Page 125
Hardware Parameter Functions
ScanSetPrefixSuffixValues Purpose Appends a prefix or one or two suffixes to scanned data. Prototype int ScanSetPrefixSuffixValues ( Char prefix, Char suffix_1, Char suffix_2);
Parameters -> prefix,
The desired ASCII values.
suffix_1 and suffix_2
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments Before setting the prefix/suffix values, set the Scan Data Transmission Format.
See Also ScanGetPrefixSuffixValues ScanSetScanDataTransmissionFormat Appendix A for prefix/suffix values
4-29
Page 126
Symbol Palm Terminal Scanner System Software Manual
ScanSetScanDataTransmissionFormat Purpose Changes the scan data transmission format. Prototype int ScanSetScanDataTransmissionFormat ( Word transmission_format);
Parameters -> transmission_ format
Must be one of the following values: DATA_AS_IS DATA_SUFFIX1 DATA_SUFFIX_2 DATA_SUFFIX1_ SUFFIX2 PREFIX_DATA PREFIX_DATA_SUFFIX1 PREFIX_DATA_SUFFIX2 PREFIX_DATA_SUFFIX1_ SUFFIX2
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
See Also ScanGetScanDataTransmissionFormat
4-30