Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 14 of 21

Symbol Palm Terminal Scanner System Software Manual: Chapter 4 Hardware Parameter Functions, pages 107 to 116

Pages 107 to 116 of 168, from Symbol Palm Terminal Scanner System Software Manual

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol SPT-1700

Page 107

Hardware Parameter Functions

ScanGetLaserOnTime Purpose Identifies the maximum scanner processing time allowed during a scan.

Prototype int ScanGetLaserOnTime ( void);

Returned Status Integer in the range [5...99], representing a time period of 0.5 to 9.9 seconds, in 0.1-second increments. If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetLaserOnTime

4-11

Page 108

Symbol Palm Terminal Scanner System Software Manual

ScanGetLinearCodeTypeSecurityLevel Purpose Identifies the number of times the barcode is scanned before being decoded.

Prototype int ScanGetLinearCodeTypeSecurityLevel ( void);

Returned Status SECURITY_LEVEL1 SECURITY_LEVEL2 SECURITY_LEVEL3 SECURITY_LEVEL4 If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also Comment for ScanSetLinearCodeTypeSecurityLevel

4-12

Page 109

Hardware Parameter Functions

ScanGetPrefixSuffixValues Purpose Identifies any prefix or suffixes appended to the scanned data. Prototype int ScanGetPrefixSuffixValues ( CharPtr pPrefix, CharPtr pSuffix_1, CharPtr pSuffix_2);

Returned Status ptr[0] returns prefix ptr[1] returns suffix_1 ptr[2] returns suffix_2 STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetPrefixSuffixValues Appendix A for prefix/suffix values

4-13

Page 110

Symbol Palm Terminal Scanner System Software Manual

ScanGetAngle Purpose Identifies the scanner’s field of view. Note: SPT 17X0-2D does not support scan angle selection.

Prototype int ScanGetAngle ( void);

Returned Status SCAN_ANGLE_WIDE SCAN_ANGLE_NARROW If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetAngle

4-14

Page 111

Hardware Parameter Functions

ScanGetScanDataTransmissionFormat Purpose Identifies the scan data transmission format. Prototype int ScanGetScanDataTransmissionFormat ( void);

Returned Status

DATA_AS_IS DATA_SUFFIX1 DATA_SUFFIX2 DATA_SUFFIX1_SUFFIX2 PREFIX_DATA PREFIX_DATA_SUFFIX1 PREFIX_DATA_SUFFIX2 PREFIX_DATA_SUFFIX1_SUFFIX2 If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetScanDataTransmissionFormat

4-15

Page 112

Symbol Palm Terminal Scanner System Software Manual

ScanGetTransmitCodeIdCharacter Purpose Determines whether a character has been selected to identify the scanned barcode’s code type and the method selected.

Prototype int ScanGetTransmitCodeIdCharacter ( void);

Returned Status AIM_CODE_ID_CHARACTER DISABLE SYMBOL_CODE_ID_CHARACTER If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetTransmitCodeIdCharacter

4-16

Page 113

Hardware Parameter Functions

ScanGetTriggeringModes Purpose Identifies the type of scan engine trigger. Prototype int ScanGetTriggeringModes ( void);

Return Status HOST LEVEL PULSE If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetTriggeringModes

4-17

Page 114

Symbol Palm Terminal Scanner System Software Manual

ScanIsPalmSymbolUnit Purpose Identifies whether the application is running on an SPT device (Palm organizer with scanner hardware and software).

Prototype int ScanIsPalmSymbolUnit ( void);

Return Status Zero=Unit is not an SPT device Non-zero=Unit is an SPT device If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

Comments Use this call when your software needs to run on both an unmodified Palm III device and an SPT device.

4-18

Page 115

Hardware Parameter Functions

ScanSetAimDuration Purpose Sets the amount of time the aiming pattern is to be seen before a scan begins.

Prototype int ScanSetAimDuration ( Word aim_duration);

Parameters -> aim_duration

Must be an integer in the range [0...99], representing a time period of 0.0 to 9.9 seconds.

Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR

Comments This function is invoked when the trigger is pressed or a ScanCmdStartDecode command is received. This function call does not apply to the aim signal or to the ScanCmdAimOn command. The aim_duration parameter is programmable in 0.1-second increments. If a value of 0 is set for aim_duration, the aim pattern is disabled.

See Also ScanGetAimDuration

4-19

Page 116

Symbol Palm Terminal Scanner System Software Manual

ScanSetAngle Purpose Sets the scanner’s field of view. Note: SPT 17X0-2D does not support scan angle selection.

Prototype int ScanSetAngle ( Word scanner_angle);

Parameters -> scanner_angle

Must be one of the following values: SCAN_ANGLE_WIDE SCAN_ANGLE_NARROW

Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR

Comments A SCAN_ANGLE_WIDE field of view allows the scanner to decode more barcode characters at the same time.

See Also ScanGetAngle

4-20