Page 97
Chapter 4 Hardware Parameter Functions Introduction The Scan Manager functions in this section give you ability to set up the scanner. With these functions, an application can perform the following: !
Set scan angle and aim duration
!
Set triggering mode
!
Set beep durations and frequencies
!
Set redundancy and security levels
!
Identify and manipulate barcode data
4-1
Page 98
Symbol Palm Terminal Scanner System Software Manual
Returned Status Definitions The hardware parameter functions may return one of the status codes described in Table 4-1. Table 4-1. Returned Status Codes STATUS CODE
4-2
DEFINITION
Any non-negative value (0 to 32767)
Parameter value.
STATUS_OK
The function’s parameters were verified. If a function must wait for an ACK from the scanner, STATUS_OK indicates that the ACK was received.
NOT_SUPPORTED
The last packet received from the scanner generated either a NAK_DENIED or NAK_BAD_CONTEXT status. This usually indicates that the specified parameter is not supported by this scanner, or the scanner was unable to comply with the request.
COMMUNICATIONS_ERROR
Either a timeout condition or the maximum number of retries (or both) occurred. The previous transmit message was not verified through an ACK, and therefore, is questionable.
BAD_PARAM
One or more of the function call parameters supplied by the user was not in the expected range.
BATCH_ERROR
The limits of a batch function have been exceeded. Unless otherwise indicated, functions that start with ScanSet are responsible for generating a batch command to establish scanner parameters. The parameters are not sent to the scanner until the ScanCmdSendParams() function is called, at which time a new batch is started.
ERROR_UNDEFINED
An error condition exists that is not specifically associated with the scanner or its communications.
Page 99
Hardware Parameter Functions
Hardware Parameter Functions Table 4-2 lists the hardware parameter functions described in this chapter. Table 4-2. Hardware Parameter Functions PARAMETER FUNCTION
PAGE
ScanGetAimDuration
4-5
ScanGetBeepAfterGoodDecode
4-6
ScanGetBeepDuration
4-7
ScanGetBeepFrequency
4-8
ScanGetBidirectionalRedundancy
4-9
ScanGetDecodeLedOnTime
4-10
ScanGetLaserOnTime
4-11
ScanGetLinearCodeTypeSecurityLevel
4-12
ScanGetPrefixSuffixValues
4-13
ScanGetAngle
4-14
ScanGetScanDataTransmissionFormat
4-15
ScanGetTransmitCodeIdCharacter
4-16
ScanGetTriggeringModes
4-17
ScanIsPalmSymbolUnit
4-18
ScanSetAimDuration
4-19
ScanSetAngle
4-20
ScanSetBeepAfterGoodDecode
4-21
ScanSetBeepDuration
4-22
ScanSetBeepFrequency
4-23
ScanSetBidirectionalRedundancy
4-24
ScanSetDecodeLedOnTime
4-25
ScanSetLaserOnTime
4-26
4-3
Page 100
Symbol Palm Terminal Scanner System Software Manual
Table 4-2. Hardware Parameter Functions
4-4
PARAMETER FUNCTION
PAGE
ScanSetLinearCodeTypeSecurityLevel
4-27
ScanSetPrefixSuffixValues
4-29
ScanSetScanDataTransmissionFormat
4-30
ScanSetTransmitCodeIdCharacter
4-31
ScanSetTriggeringModes
4-38
Page 101
Hardware Parameter Functions
ScanGetAimDuration Purpose Identifies the amount of time the aiming pattern is seen before a scan begins.
Prototype int ScanGetAimDuration ( void);
Returned Status Integer in the range [0...99], representing a time period of 0.0 to 9.9 seconds, in 0.1-second increments. If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED
See Also ScanSetAimDuration
4-5
Page 102
Symbol Palm Terminal Scanner System Software Manual
ScanGetBeepAfterGoodDecode Purpose Identifies whether the unit has been set to beep after a good decode.
Prototype int ScanGetBeepAfterGoodDecode ( void);
Returned Status Zero=DISABLE >zero=ENABLE If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED
See Also ScanSetBeepAfterGoodDecode
4-6
Page 103
Hardware Parameter Functions
ScanGetBeepDuration Purpose Identifies the duration of the beep for the specified beep types. Prototype int ScanGetBeepDuration ( DurationType type);
Parameters -> type
Must be one of the following values: DECODE SHORT MEDIUM LONG
Returned Status STATUS_OK See Also ScanSetBeepDuration
4-7
Page 104
Symbol Palm Terminal Scanner System Software Manual
ScanGetBeepFrequency Purpose Gets the frequency of the beeper for the specified beep types. Prototype int ScanGetBeepFrequency ( FrequencyType beep_type);
Parameters -> beep_type
Must be one of the following values: DECODE LOW MEDIUM HIGH
Returned Status STATUS_OK See Also ScanSetBeepFrequency
4-8
Page 105
Hardware Parameter Functions
ScanGetBidirectionalRedundancy Purpose Identifies whether a barcode must be successfully scanned in both directions before being decoded.
Prototype int ScanGetBidirectionalRedundancy ( void);
Returned Status ENABLE DISABLE If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED
See Also ScanSetBidirectionalRedundancy
4-9
Page 106
Symbol Palm Terminal Scanner System Software Manual
ScanGetDecodeLedOnTime Purpose Identifies the amount of time the LED is to be turned on when a successful scan is performed.
Prototype int ScanGetDecodeLedOnTime ( void);
Returned Status Integer in the range [0...100], representing a time period of 0.0 to 10.0 seconds, in 0.1-second increments. If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED
See Also ScanSetDecodeLedOnTime
4-10