Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 21

Symbol Palm Terminal Scanner System Software Manual: Chapter 4 Hardware Parameter Functions, pages 97 to 106

Pages 97 to 106 of 168, from Symbol Palm Terminal Scanner System Software Manual

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol SPT-1700

Page 97

Chapter 4 Hardware Parameter Functions Introduction The Scan Manager functions in this section give you ability to set up the scanner. With these functions, an application can perform the following: !

Set scan angle and aim duration

!

Set triggering mode

!

Set beep durations and frequencies

!

Set redundancy and security levels

!

Identify and manipulate barcode data

4-1

Page 98

Symbol Palm Terminal Scanner System Software Manual

Returned Status Definitions The hardware parameter functions may return one of the status codes described in Table 4-1. Table 4-1. Returned Status Codes STATUS CODE

4-2

DEFINITION

Any non-negative value (0 to 32767)

Parameter value.

STATUS_OK

The function’s parameters were verified. If a function must wait for an ACK from the scanner, STATUS_OK indicates that the ACK was received.

NOT_SUPPORTED

The last packet received from the scanner generated either a NAK_DENIED or NAK_BAD_CONTEXT status. This usually indicates that the specified parameter is not supported by this scanner, or the scanner was unable to comply with the request.

COMMUNICATIONS_ERROR

Either a timeout condition or the maximum number of retries (or both) occurred. The previous transmit message was not verified through an ACK, and therefore, is questionable.

BAD_PARAM

One or more of the function call parameters supplied by the user was not in the expected range.

BATCH_ERROR

The limits of a batch function have been exceeded. Unless otherwise indicated, functions that start with ScanSet are responsible for generating a batch command to establish scanner parameters. The parameters are not sent to the scanner until the ScanCmdSendParams() function is called, at which time a new batch is started.

ERROR_UNDEFINED

An error condition exists that is not specifically associated with the scanner or its communications.

Page 99

Hardware Parameter Functions

Hardware Parameter Functions Table 4-2 lists the hardware parameter functions described in this chapter. Table 4-2. Hardware Parameter Functions PARAMETER FUNCTION

PAGE

ScanGetAimDuration

4-5

ScanGetBeepAfterGoodDecode

4-6

ScanGetBeepDuration

4-7

ScanGetBeepFrequency

4-8

ScanGetBidirectionalRedundancy

4-9

ScanGetDecodeLedOnTime

4-10

ScanGetLaserOnTime

4-11

ScanGetLinearCodeTypeSecurityLevel

4-12

ScanGetPrefixSuffixValues

4-13

ScanGetAngle

4-14

ScanGetScanDataTransmissionFormat

4-15

ScanGetTransmitCodeIdCharacter

4-16

ScanGetTriggeringModes

4-17

ScanIsPalmSymbolUnit

4-18

ScanSetAimDuration

4-19

ScanSetAngle

4-20

ScanSetBeepAfterGoodDecode

4-21

ScanSetBeepDuration

4-22

ScanSetBeepFrequency

4-23

ScanSetBidirectionalRedundancy

4-24

ScanSetDecodeLedOnTime

4-25

ScanSetLaserOnTime

4-26

4-3

Page 100

Symbol Palm Terminal Scanner System Software Manual

Table 4-2. Hardware Parameter Functions

4-4

PARAMETER FUNCTION

PAGE

ScanSetLinearCodeTypeSecurityLevel

4-27

ScanSetPrefixSuffixValues

4-29

ScanSetScanDataTransmissionFormat

4-30

ScanSetTransmitCodeIdCharacter

4-31

ScanSetTriggeringModes

4-38

Page 101

Hardware Parameter Functions

ScanGetAimDuration Purpose Identifies the amount of time the aiming pattern is seen before a scan begins.

Prototype int ScanGetAimDuration ( void);

Returned Status Integer in the range [0...99], representing a time period of 0.0 to 9.9 seconds, in 0.1-second increments. If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetAimDuration

4-5

Page 102

Symbol Palm Terminal Scanner System Software Manual

ScanGetBeepAfterGoodDecode Purpose Identifies whether the unit has been set to beep after a good decode.

Prototype int ScanGetBeepAfterGoodDecode ( void);

Returned Status Zero=DISABLE >zero=ENABLE If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetBeepAfterGoodDecode

4-6

Page 103

Hardware Parameter Functions

ScanGetBeepDuration Purpose Identifies the duration of the beep for the specified beep types. Prototype int ScanGetBeepDuration ( DurationType type);

Parameters -> type

Must be one of the following values: DECODE SHORT MEDIUM LONG

Returned Status STATUS_OK See Also ScanSetBeepDuration

4-7

Page 104

Symbol Palm Terminal Scanner System Software Manual

ScanGetBeepFrequency Purpose Gets the frequency of the beeper for the specified beep types. Prototype int ScanGetBeepFrequency ( FrequencyType beep_type);

Parameters -> beep_type

Must be one of the following values: DECODE LOW MEDIUM HIGH

Returned Status STATUS_OK See Also ScanSetBeepFrequency

4-8

Page 105

Hardware Parameter Functions

ScanGetBidirectionalRedundancy Purpose Identifies whether a barcode must be successfully scanned in both directions before being decoded.

Prototype int ScanGetBidirectionalRedundancy ( void);

Returned Status ENABLE DISABLE If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetBidirectionalRedundancy

4-9

Page 106

Symbol Palm Terminal Scanner System Software Manual

ScanGetDecodeLedOnTime Purpose Identifies the amount of time the LED is to be turned on when a successful scan is performed.

Prototype int ScanGetDecodeLedOnTime ( void);

Returned Status Integer in the range [0...100], representing a time period of 0.0 to 10.0 seconds, in 0.1-second increments. If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED

See Also ScanSetDecodeLedOnTime

4-10