The text of a manual · part 12 of 21
Symbol Palm Terminal Scanner System Software Manual: Chapter 3 Barcode Parameter Functions, pages 90 to 96
Pages 90 to 96 of 168, from Symbol Palm Terminal Scanner System Software Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol SPT-1700
Page 90
Symbol Palm Terminal Scanner System Software Manual
!
If you select the autodiscriminate_supplementals parameter, you can adjust the number of times a symbol is scanned to ensure that both the barcode and the supplementals are correctly decoded. If you use autodiscriminate, consider setting redundancy to greater than five.
See Also ScanGetDecodeUpcEanSupplementals
3-46
Page 91
Barcode Parameter Functions
ScanSetEanZeroExtend Purpose When enabled, adds five leading zeros to decoded EAN-8 symbols.
Prototype int ScanSetEanZeroExtend ( Boolean bEnable);
Parameters -> bEnable
Must be one of the following values: True=ENABLE False=DISABLE
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments This function call makes EAN-8 symbols compatible to EAN-13 symbols.
See Also ScanGetEanZeroExtend
3-47
Page 92
Symbol Palm Terminal Scanner System Software Manual
ScanSetUpcEanSecurityLevel Purpose Selects the number of times the barcode is to be scanned before being decoded.
Prototype int ScanSetUpcEanSecurityLevel ( Word security_level);
Parameters -> security_level
Must be one of the following values: SECURITY_LEVEL0 SECURITY_LEVEL1 SECURITY_LEVEL2 SECURITY_LEVEL3
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments The SPT scanner offers four levels of decoding security for UPC/ EAN barcodes. Security levels determine the number of times linear barcodes (such as Code 39 or I 2 of 5) are scanned before being decoded. Higher security levels are needed for decreasing barcode quality. Data must be decoded the same twice in a row for the scan to be considered good. As security levels increase, the scanner’s aggressiveness decreases, so be sure to choose only that level of security necessary for any given application.
3-48
Page 93
Barcode Parameter Functions
Security Level 0 - The default setting. Allows the scanner to operate in its most aggressive state, while providing sufficient security for decoding in-spec barcodes. Security Level 1 - As barcode quality levels diminish, certain characters (1, 2, 7, or 8) become prone to misdecodes. Select this security level if you are experiencing misdecodes because of poorly printed barcodes, and the misdecodes are limited to these characters. Security Level 2 - Select this security level if you are experiencing misdecodes of poorly printed barcodes, and the misdecodes are not limited to characters 1, 2, 7, or 8. Security Level 3 - Select this security level if you have tried Security Level 2 and are still experiencing misdecodes. This security level significantly impairs the decoding ability of the scanner. If this level of security is necessary, try to improve the barcode’s quality.
See Also ScanGetUpcEanSecurityLevel
3-49
Page 94
Symbol Palm Terminal Scanner System Software Manual
ScanSetUpcPreamble Purpose Determines whether the specified UPC code is to be transmitted with lead-in characters.
Prototype int ScanSetUpcPreamble ( BarType barcodeType, int preamble);
Parameters -> barcodeType
Must be one of the following values: barUPCA barUPCE barUPCE1
-> preamble
Must be one of the following values: NO_PREAMBLE SYSTEM_CHARACTER SYSTEM_CHARACTER_ COUNTRY_CODE
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
3-50
Page 95
Barcode Parameter Functions
Comments Three options are given for transmitting lead-in characters (preamble) added to UPC-A symbols: !
Transmit system character only
!
Transmit system character and country code (“0” for USA)
!
Do not transmit the preamble
The preamble is considered part of the symbol.
See Also ScanGetUpcPreamble
3-51
Page 96
Symbol Palm Terminal Scanner System Software Manual
3-52