The text of a manual · part 10 of 21
Symbol Palm Terminal Scanner System Software Manual: Chapter 3 Barcode Parameter Functions, pages 72 to 80
Pages 72 to 80 of 168, from Symbol Palm Terminal Scanner System Software Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol SPT-1700
Page 72
Symbol Palm Terminal Scanner System Software Manual
Converting EAN-8 to EAN-13 - When EAN Zero Extend is disabled, this parameter has no effect on barcode data. Converting I 2 of 5 to EAN-13 - The I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.
See Also ScanGetConvert
3-28
Page 73
Barcode Parameter Functions
ScanSetTransmitCheckDigit Purpose Determines whether the specified code is to be transmitted with a check digit.
Prototype int ScanSetTransmitCheckDigit ( BarType barcodeType, Word check_digit);
Parameters -> barcodeType
Must be one of the following values: barUPCA barUPCE barUPCE1 barCODE39 barI2OF5 barMSI_PLESSEY
-> check_digit
Must be one of the following values: TRANSMIT_CHECK_ DIGIT DO_NOT_TRANSMIT_ CHECK_DIGIT
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments Check digits are used by the scanner to validate that the correct data has been decoded. In UPC code, the check digit’s value is based on the other data in the barcode.
See Also ScanGetTransmitCheckDigit
3-29
Page 74
Symbol Palm Terminal Scanner System Software Manual
I 2 of 5 Barcode Parameter Functions Table 3-7 lists the I 2 of 5 barcode parameter functions described in this section. Table 3-7. I 2 of 5 Barcode Parameter Functions PARAMETER FUNCTION
3-30
PAGE
ScanGetI2of5CheckDigitVerification
3-31
ScanSetI2of5CheckDigitVerification
3-32
Page 75
Barcode Parameter Functions
ScanGetI2of5CheckDigitVerification Purpose Identifies whether an I 2 of 5 symbol is complying with specified algorithms.
Prototype int ScanGetI2of5CheckDigitVerification ( void);
Returned Status DISABLE OPCC_CHECK_DIGIT USS_CHECK_DIGIT If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED
See Also ScanSetI2of5CheckDigitVerification
3-31
Page 76
Symbol Palm Terminal Scanner System Software Manual
ScanSetI2of5CheckDigitVerification Purpose Determines whether an I 2 of 5 symbol is to comply with specified algorithms.
Prototype int ScanSetI2of5CheckDigitVerification ( Word check_digit);
Parameters -> check_digit
Must be one of the following values: DISABLE USS_CHECK_DIGIT OPCC_CHECK_DIGIT
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
Comments The I 2 of 5 symbol must comply with one of the following algorithms: !
Optical Product Code Council (OPCC)
!
Uniform Symbology Specification (USS)
See Also ScanGetI2of5CheckDigitVerification
3-32
Page 77
Barcode Parameter Functions
MSI Plessey Barcode Parameter Functions Table 3-8 lists the MSI Plessey barcode parameter functions described in this section. Table 3-8. MSI Plessey Barcode Parameter Functions PARAMETER FUNCTION
PAGE
ScanGetMsiPlesseyCheckDigit Algorithm
3-34
ScanGetMsiPlesseyCheckDigits
3-35
ScanSetMsiPlesseyCheckDigit Algorithm
3-36
ScanSetMsiPlesseyCheckDigits
3-37
3-33
Page 78
Symbol Palm Terminal Scanner System Software Manual
ScanGetMsiPlesseyCheckDigit Algorithm Purpose Determines whether MSI Plessey-encoded symbols with two check digits are being verified a second time before being transmitted.
Prototype int ScanGetMsiPlessey CheckDigitAlgorithm ( void);
Returned Status MOD10_MOD11 MOD10_MOD10 If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED
See Also ScanSetMsiPlesseyCheckDigitAlgorithm
3-34
Page 79
Barcode Parameter Functions
ScanGetMsiPlesseyCheckDigits Purpose Determines the number of check digits that are being inserted at the end of MSI Plessey-encoded data.
Prototype int ScanGetMsiPlesseyCheckDigits ( void);
Return Status ONE_CHECK_DIGIT TWO_CHECK_DIGITS If an error occurs, the returned status is one of the following: COMMUNICATIONS_ERROR NOT_SUPPORTED
See Also ScanSetMsiPlesseyCheckDigits
3-35
Page 80
Symbol Palm Terminal Scanner System Software Manual
ScanSetMsiPlesseyCheckDigit Algorithm Purpose Determines whether MSI Plessey-encoded symbols with two check digits are to be verified a second time before being transmitted.
Prototype int ScanSetMsiPlessey CheckDigitAlgorithm ( Word algorithm);
Parameters -> algorithm
Must be one of the following values: MOD10_MOD11 MOD10_MOD10
Returned Status STATUS_OK If an error occurs, the returned status is one of the following: BAD_PARAM BATCH_ERROR
See Also ScanGetMsiPlesseyCheckDigitAlgorithm
3-36