Page 165

Appendix B Parameter Definitions Table B-1 lists the parameters available in the Scan Manager shared library. The information in this table includes parameter name, the terminal default setting, and the acceptable values. Table B-1. Parameter Definitions DEFAULT SETTING

PARAMETER

All defaults

ParamDefaults BeepFrequency

BeepDuration

ACCEPTABLE VALUES

Decode

3000 Hz

Low

1500 Hz

Medium

3000 Hz

High

7500 Hz

Decode

90 ms

Short

70 ms

Medium

90 ms

Long

240 ms

0 - 15,000 Hz

0 - 10,000 ms

LaserOnTime

3.0 seconds

0 - 10

AimDuration

0.0 seconds

TriggeringModes

Level

Level, Pulse, Host

BeepAfterGoodDecode

Enable

Enable, Disable B-1

Page 166

Symbol Palm Terminal Scanner System Software Manual

Table B-1. Parameter Definitions DEFAULT SETTING

PARAMETER

ACCEPTABLE VALUES

LinearCodeTypeSecurityLevel

Security_Level1 Level1 - Level4

BidirectionalRedundancy

Disable

BarcodeEnabled

UPC-A

Enable

UPC-E

Enable

UPC-E1

Disable

EAN-8

Enable

EAN-13

Enable

Bookland EAN

Disable

Code 128

Enable

UCC/EAN-128

Enable

ISBT 128

Enable

Code 39

Enable

Trioptic Code 39 Disable Code 93

Disable

I2of5

Enable

D2of5

Disable

Codabar

Disable

MSI Plessey

Disable

DecodeUpcEanSupplementals

Ignore

DecodeUpcEanRedundancy

7

TransmitCheckDigit

B-2

UPC-A

Enable

UPC-E

Enable

UPC-E1

Enable

2-20

Page 167

Parameter Definitions

Table B-1. Parameter Definitions DEFAULT SETTING

PARAMETER TransmitCheckDigit (cont’d)

UpcPreamble

Convert

Code 39

Disable

I2of5

Disable

MSI Plessey

Disable

UPC-A

System character

UPC-E

System character

UPC-E1

System character

UPC-E to A

Disable

UPC-E1 to A

Disable

EAN-8 to EAN13

Type is EAN-13

ACCEPTABLE VALUES

Code 39 to Code Disable 32 I2of5 to EAN-13 Disable EanZeroExtend

Disable

UpcEanSecurityLevel

0

Code32Prefix

Disable

BarcodeLengths

Code 39

2-32

Code 93

4-55

I2of5

14

D2of5

12

Codabar

5-55

Level 1 - Level 4

B-3

Page 168

Symbol Palm Terminal Scanner System Software Manual

Table B-1. Parameter Definitions DEFAULT SETTING

PARAMETER BarcodeLengths (cont’d)

MSI Plessey

6-55

Code39CheckDigitVerification

Disable

Code39FullAscii

Disable

I2of5CheckDigitVerification

Disable

ClsiEditing

Disable

NotisEditing

Disable

MsiPlesseyCheckDigits

One

MsiPlesseyCheckDigitAlgorithm

Mod 10/Mod 10

TransmitCodeIdCharacter

None

PrefixSuffixValues

ACCEPTABLE VALUES

Prefix

Null

Suffix 1

LF

Suffix 2

CR

One, Two

ScanDataTransmissionFormat

Data as is

ScanAngle

Wide

Wide, Narrow

DecodeLedOnTime

3 seconds

0 - 99

B-4