Page 165
Appendix B Parameter Definitions Table B-1 lists the parameters available in the Scan Manager shared library. The information in this table includes parameter name, the terminal default setting, and the acceptable values. Table B-1. Parameter Definitions DEFAULT SETTING
PARAMETER
All defaults
ParamDefaults BeepFrequency
BeepDuration
ACCEPTABLE VALUES
Decode
3000 Hz
Low
1500 Hz
Medium
3000 Hz
High
7500 Hz
Decode
90 ms
Short
70 ms
Medium
90 ms
Long
240 ms
0 - 15,000 Hz
0 - 10,000 ms
LaserOnTime
3.0 seconds
0 - 10
AimDuration
0.0 seconds
TriggeringModes
Level
Level, Pulse, Host
BeepAfterGoodDecode
Enable
Enable, Disable B-1
Page 166
Symbol Palm Terminal Scanner System Software Manual
Table B-1. Parameter Definitions DEFAULT SETTING
PARAMETER
ACCEPTABLE VALUES
LinearCodeTypeSecurityLevel
Security_Level1 Level1 - Level4
BidirectionalRedundancy
Disable
BarcodeEnabled
UPC-A
Enable
UPC-E
Enable
UPC-E1
Disable
EAN-8
Enable
EAN-13
Enable
Bookland EAN
Disable
Code 128
Enable
UCC/EAN-128
Enable
ISBT 128
Enable
Code 39
Enable
Trioptic Code 39 Disable Code 93
Disable
I2of5
Enable
D2of5
Disable
Codabar
Disable
MSI Plessey
Disable
DecodeUpcEanSupplementals
Ignore
DecodeUpcEanRedundancy
7
TransmitCheckDigit
B-2
UPC-A
Enable
UPC-E
Enable
UPC-E1
Enable
2-20
Page 167
Parameter Definitions
Table B-1. Parameter Definitions DEFAULT SETTING
PARAMETER TransmitCheckDigit (cont’d)
UpcPreamble
Convert
Code 39
Disable
I2of5
Disable
MSI Plessey
Disable
UPC-A
System character
UPC-E
System character
UPC-E1
System character
UPC-E to A
Disable
UPC-E1 to A
Disable
EAN-8 to EAN13
Type is EAN-13
ACCEPTABLE VALUES
Code 39 to Code Disable 32 I2of5 to EAN-13 Disable EanZeroExtend
Disable
UpcEanSecurityLevel
0
Code32Prefix
Disable
BarcodeLengths
Code 39
2-32
Code 93
4-55
I2of5
14
D2of5
12
Codabar
5-55
Level 1 - Level 4
B-3
Page 168
Symbol Palm Terminal Scanner System Software Manual
Table B-1. Parameter Definitions DEFAULT SETTING
PARAMETER BarcodeLengths (cont’d)
MSI Plessey
6-55
Code39CheckDigitVerification
Disable
Code39FullAscii
Disable
I2of5CheckDigitVerification
Disable
ClsiEditing
Disable
NotisEditing
Disable
MsiPlesseyCheckDigits
One
MsiPlesseyCheckDigitAlgorithm
Mod 10/Mod 10
TransmitCodeIdCharacter
None
PrefixSuffixValues
ACCEPTABLE VALUES
Prefix
Null
Suffix 1
LF
Suffix 2
CR
One, Two
ScanDataTransmissionFormat
Data as is
ScanAngle
Wide
Wide, Narrow
DecodeLedOnTime
3 seconds
0 - 99