Page 1 of Ultra High Accuracy Laser Displacement Meter LC-2400 Series Instruction Manual

Manual · Keyence

Ultra High Accuracy Laser Displacement Meter LC-2400 Series Instruction Manual

Manual121 pagesPDF 805 KB

Instruction manual for the Keyence LC-2400 series ultra high accuracy laser displacement meter, including the LC-2400A controller.

Download the PDF805 KB

Covers · 1 model

The models it covers

Summary

What is in it

Keyence's instruction manual for the LC-2400 series laser displacement meter: the LC controller (display unit and control unit) and the LC-2420, LC-2430, LC-2440 and LC-2450 sensor heads. Its nine chapters cover laser safety, system configuration and expansion boards, part names, operating instructions, connections, setting up measurement parameters, measuring with one or two sensor heads, the RS-232C, control I/O, analog and digital external I/O, and an appendix with troubleshooting, specifications and dimensions.

Its parts

  1. Laser Safety Precautions
  2. System Configuration
  3. Part Names and Functions
  4. Operating Instructions
  5. Connections
  6. Setting Up
  7. Measurement Procedure
  8. External Input/Output
  9. Appendix

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Keyence's instruction manual (96M0334) for the LC-2400 Series ultra high accuracy laser displacement meter, covering the LC-2400A and LC-2400W controllers and the LC-2420, LC-2430, LC-2440 and LC-2450 sensor heads. It explains installation and connections, setting up and calibrating measurements, the RS-232C and other external I/O, troubleshooting and error messages, and the specifications.

Read for this summary: pages 1 to 7, 13 to 16, 19 and 87 to 91 of 121.

Device
Laser displacement meter: a controller (display unit and control unit) with one or two sensor heads p. 13
Sensor heads
LC-2420 and LC-2430 regular-reflective, for mirror-like surfaces; LC-2440 and LC-2450 diffuse-reflective, for opaque surfaces p. 15
Controller units
Display unit LC-D1A/LC-D1W; control unit LC-C1A/LC-C1W/LC-C2 p. 13
Light source
Visible red semiconductor laser, 670 nm, maximum output 1.9 mW p. 91
Expansion boards
LC-B3 2CH sensor head board; LC-B1 DIGITAL I/O or LC-B2 GP-IB board; not usable with the LC-2400W p. 13
Interfaces
RS-232C (75 to 19200 bps), analog voltage output and control I/O port p. 14, 91
Control outputs
NPN open-collector, 100 mA (30 V) max., for upper/lower limit, intensity alarm and AREA OVER alarm p. 91
Control inputs
Non-voltage inputs for HOLD timing, AUTO-ZERO, program selection, 1CH/2CH selection and LASER REMOTE p. 91
Response
Response frequency (Hz) is 20000 divided by the number of averaging measurements p. 90
Power
100 to 240 VAC ±10%, 50/60 Hz; 70 VA max. p. 91
Fuse
250 V, 3.15 A, fast, high breaking p. 91
Ambient temperature
0 to 40°C (32 to 104°F), no freezing p. 91
Controller weight
Approx. 6.8 kg (approx. 2 kg without the display unit) p. 91
In the package
3-m connecting cable, 2-m power cable, power supply keys, 24-pin control I/O connector, 4-pin laser remote grounding plug p. 3

What this manual walks you through

  • Connecting the sensor head and power supply cable, and grounding the controller p. 6
  • Installing the LC-B3, GP-IB or DIGITAL I/O board p. 6
  • Adjusting the sensor head position p. 6
  • Selecting gain and calibrating to correct measurement error p. 7
  • Setting averaging, low-pass filter and upper/lower tolerance limits p. 7
  • Storing and loading settings as programs p. 7
  • Measuring with one or two sensor heads p. 7
  • Communicating over RS-232C and the control I/O p. 7
  • Troubleshooting missing or inaccurate readings p. 87, 88
  • Reading the error message list p. 89

Good to know

  • Turn the power off before connecting or disconnecting the sensor head connector, power cables or optional boards. p. 2
  • The control unit and the sensor head must have the same serial number. p. 87
  • A unit calibrated for the 3-m cable must be recalibrated by KEYENCE to use a 5-m or 10-m cable; those cables are not available for the LC-2400W. p. 3
  • The LC-2400 series must not be used to protect the human body. p. 2

Questions this manual answers

What does Connection error mean on a Keyence LC-2400?

Pins 1 and 2 of the LASER REMOTE connector are not shorted, no sensor head is connected, or the connecting cable is disconnected. p. 89

Why can't the LC-2400 talk to my PC over RS-232C?

A null modem cable may be in use; the manual calls for a standard serial cable and matching baud rate and data format. p. 88

What do Far and Near mean on the LC-2400 display?

The sensor-to-target distance is outside the measuring range by at least 5%. p. 89

Which sensor heads work with the LC-2400 controller?

The LC-2420, LC-2430, LC-2440 and LC-2450; the first two are regular-reflective and the last two diffuse-reflective. p. 15

Why does the LC-2400 measurement value fluctuate?

The manual lists a dirty transmitter/receiver, wrong gain or too few averaging measurements as causes. p. 87

The whole text · 13 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Page 121121

The file

Revision and size

Revision96M0334
PublisherKeyence
Pages121
PDF805 KB
TextText from the PDF itself; page 18 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 121

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 121
Page 2
Page 2of 121
Page 3
Page 3of 121

More documents · 1

For the same models