Page 1 of LT 1804 (RS-232/Synapse) Product Reference Guide

Manual · Symbol

LT 1804 (RS-232/Synapse) Product Reference Guide

Manual129 pagesPDF 710 KB

Product reference guide for the Symbol LT 1804 hand-held laser scanner with RS-232 and Synapse interfaces: setup, specs and programming.

Download the PDF710 KB

Names · 1 model

The models it names

Filed with · 7 models

Also filed with these models on the old site

Summary

What is in it

Product reference guide for the Symbol LT 1804, a hand-held close range laser scanner with on-board RS-232C communications and support for Synapse smart cables. It covers unpacking, connecting with a power supply or a 9-volt battery pack, Synapse configuration, scanning and the decode zone, maintenance, accessories, technical specifications, signal descriptions and cable pinouts, then the full programming chapter and parameter menus with defaults.

Its parts

  1. About This Manual
  2. Setting Up the LT 1804
  3. Scanning with the LT 1804
  4. Maintenance and Specifications
  5. Programming the LT 1804
  6. Parameter Menus

From the manual

Key facts from this manual

Each line names its page in the PDF.

The Product Reference Guide (70-32537-01, Revision A, October 1997) for the Symbol LT 1804, an RS-232 and Synapse version of the hand-held laser scanner. It covers connecting the scanner on a power supply or 9-volt battery pack, scanning, cleaning, accessory part numbers, specifications, cable pinouts and programming every parameter by scanning bar codes. Only the LT 1804 is described.

Read for this summary: pages 1, 8 to 28 and 38 to 43 of 129.

Device
Hand-held close range bar code scanner with a visible laser diode p. 8
Interfaces
On-board RS-232C, or Synapse Smart Cables for other hosts p. 9
Power
5 VDC plus or minus 10%; 120 mA average, 160 mA peak p. 19
Battery
9-volt alkaline or nickel-cadmium rechargeable in a battery pack p. 11
Range
Up to 5.0 in (12.70 cm) on 100% UPC/EAN; 5.5 mil minimum element width p. 19
Symbologies
UPC/EAN, UCC/EAN 128, Code 39, Code 39 Full ASCII, Codabar, Interleaved 2 of 5, Code 128, Discrete 2 of 5, Code 93 p. 19
Weight and size
6.0 oz (170 g) without cable; 8.0 in (20.3 cm) long p. 19, 20
Operating temperature
32 to 104 F (0 to 40 C) p. 19
Baud rates
300 to 19,200; default 9600 p. 39
Power supplies
50-14000-005 (117V input) and 50-04000-083 (220/240V input), both 5V output p. 17
RS-232 cable
25-17837-02 female 9-pin straight cable with power jack; 9-pin to 25-pin adapters 50-12100-377 to -380 p. 17
Battery parts
20-10615-01 battery box (5V regulated), 25-09075-01 straight cable, 25-08892-01 3-foot extension p. 18
Synapse cable
25-31617-01, 6-foot straight cable p. 18
Stands and holster
Hands-free stands 20-12769-01, 20-08414-01, 20-08415-01; desk 21-08288-02; wall 23-08253-01; holster 20-08416-01 p. 18

What this manual walks you through

  • Connecting to an RS-232 host with the power supply p. 10
  • Running on a 9-volt battery pack with a portable terminal p. 11, 12
  • Changing and recharging the battery p. 12
  • Connecting through a Synapse Smart Cable p. 13
  • Scanning in triggered and triggerless modes and the decode zone p. 14, 15
  • Cleaning the window and what to check when nothing happens p. 16
  • Scanner and 25-pin interface cable pinouts p. 21, 22, 23, 24, 25
  • Programming parameters with scanning sequences, BACKSPACE and CANCEL p. 26, 27, 28
  • Default settings and ICL, Fujitsu and Nixdorf host defaults p. 38, 39, 40, 41
  • What the beeper sequences mean p. 42, 43

Good to know

  • Power down the host before connecting the scanner. p. 10
  • Four short high beeps on battery mean low voltage and no further scanning until the battery is changed or recharged. p. 42
  • Do not remove the scanner nose, and keep abrasives off the window. p. 16
  • Do not enable Transmit Code ID for ICL, Fujitsu or Nixdorf hosts, which send their own code IDs. p. 41
  • In Nixdorf Mode B, scanning is disabled while CTS is low. p. 40

Questions this manual answers

What power does the Symbol LT 1804 need?

5 VDC plus or minus 10%, about 120 mA average and 160 mA peak, from a 5V power supply or a 9-volt battery pack. p. 19

How far can the LT 1804 read a bar code?

Up to about 5.0 inches on a 100% UPC/EAN code, with 5.5 mil the smallest element width. p. 19

How do I reset the LT 1804 to factory defaults?

Scan the SET DEFAULT bar code in the parameter menus. p. 26

What do four long low beeps mean on the LT 1804?

A transmission error: the last data scanned was lost, so scan it again. p. 42

What is the part number of the LT 1804 power supply?

50-14000-005 for 117V input or 50-04000-083 for 220/240V input, both with 5V output. p. 17

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. About This Manual6
    1. Notational Conventions6
    2. Related Publications6
    3. Service Information6
    4. Symbol Support Center7
  2. Chapter 1 Setting Up the LT 18048
    1. Overview8
    2. Unpacking9
    3. Connecting Your LT 18049
  3. Chapter 2 Scanning with the LT 180414
    1. Scanning14
    2. LT 1804 Decode Zone15
  4. Chapter 3 Maintenance and Specifications16
    1. Maintenance16
    2. What If...16
    3. Accessories17
    4. Technical Specifications19
    5. LT 1804 Dimensions20
    6. LT 1804 Signal Descriptions21
    7. Interface Cable Pinouts22
  5. Chapter 4 Programming the LT 180426
    1. Scanning Sequences26
    2. Errors While Scanning27
    3. Parameter Descriptions29
    4. Standard Defaults38
    5. RS-232 Host Type Defaults40
    6. RS-232C Code ID Characters41
    7. Beeper Definitions42
    8. Code 39 Buffering (Scan and Store)44
    9. Communication Protocols46
    10. ASCII Conversion Tables49
  6. Chapter 5 Parameter Menus56
    1. Set Default56
    2. RS-232 Host Type57
    3. Code Types59
    4. Fixed Lengths For Code 2 of 562
    5. Decode Options66
    6. UPC/EAN Supplementals Option69
    7. Beep After Good Decode71
23 more lines, from page 73 on
  1. Beeper Volume73
    1. Trigger Mode (for triggered models only)75
    2. Decode Redundancy77
    3. Code 39 Scan and Store79
    4. Baud Rate81
    5. Parity84
    6. Hardware Handshaking86
    7. Software Handshaking88
    8. RTS Line State90
    9. Host Serial Response Timeout92
    10. Transmit “NO DECODE” Character95
    11. Stop Bit Select97
    12. Scan Data Transmission Format99
    13. Prefix101
    14. Suffix105
    15. Prefix/Suffix (Synapse)110
    16. Communications Delays and Timeouts113
    17. UPC-E/UPC-A Preamble116
    18. Data Format118
  2. Glossary120
  3. Index126
  4. Feedback129
  5. Copyright2

From the PDF’s own bookmarks.

The whole text · 15 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Contents1-5
  2. Pages 6 to 136-13
  3. Pages 14 to 2514-25
  4. Chapter 4 Programming the LT 1804, pages 26 to 3526-35
  5. Chapter 4 Programming the LT 1804, pages 36 to 4536-45
  6. Chapter 4 Programming the LT 1804, pages 46 to 5546-55
  7. Chapter 5 Parameter Menus, pages 56 to 6556-65
  8. Chapter 5 Parameter Menus, pages 66 to 7566-75
  9. Chapter 5 Parameter Menus, pages 76 to 8576-85
  10. Chapter 5 Parameter Menus, pages 86 to 9586-95
  11. Chapter 5 Parameter Menus, pages 96 to 10596-105
  12. Chapter 5 Parameter Menus, pages 106 to 115106-115
  13. Chapter 5 Parameter Menus, pages 116 to 119116-119
  14. Glossary120-125
  15. Pages 126 to 129126-129

The file

Revision and size

Revision70-32537-01 Revision A, October 1997
PublisherSymbol Technologies, Inc.
Pages129
PDF710 KB