LT 1804 (RS-232/Synapse) Product Reference Guide, pages 6 to 13

Pages 6 to 13 of 129: About This Manual; Chapter 1 Setting Up the LT 1804

The original document is the PDF (710 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LT-1804

Page 6

About This Manual The LT 1804 Product Reference Guide provides general instructions for setup, operation, troubleshooting, maintenance, and programming.

Notational Conventions The following conventions are used in this document: • Bullets (•) indicate:

- action items - lists of alternatives - lists of required steps that are not necessarily sequential • Sequential lists (e.g., those that describe step-by-step procedures) appear as numbered lists.

Related Publications • LT 1810/1804 Quick Reference Guide

70-31612-XX

Service Information If you have a problem with your equipment, contact the Symbol Support Center. Before calling, have the model number, serial number, and several of your bar code symbols at hand. Call the Support Center from a phone near the scanning equipment so that the service person can try to talk you through your problem. If the equipment is found to be working properly and the problem is symbol readability, the Support Center will request samples of your bar codes for analysis at our plant.

About-i

Page 7

LT 1804 Product Reference Guide: About This Manual

If your problem cannot be solved over the phone, you may need to return your equipment for servicing. If that is necessary, you will be given specific directions. Note: Symbol Technologies is not responsible for any damages incurred during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping container was not kept, contact Symbol to have another sent to you.

Symbol Support Center In the U.S.A, for service information, warranty information or technical assistance, call: SYMBOL SUPPORT CENTER 1-800-653-5350 If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.

Canada Mississauga, Ontario Canadian Headquarters (905) 629-7226

Europe Wokingham, England European Headquarters 0734-771-222 (Inside UK) +441-734-771222 (Outside UK)

Asia Singapore Symbol Technologies Asia, Inc. 337-6588 (Inside Singapore) +65-337-6588 (Outside Singapore) About-ii

Page 8

Chapter 1 Setting Up the LT 1804 Overview LT 1804 provides the best all-around close range scanning performance, reliability, and value available. Its physical design, which combines a lightweight yet solid feel with excellent ergonomics for scanning, ensures comfortable use. The LT 1804 hand-held scanner is based on the Visible Laser Diode (VLD) as a light source. Combined with our surface mount technology and patented resonating harmonic scan element, this state-of-the-art scanner provides solid state dependability. When you add this scanner to your system, you add efficient, reliable bar code reading capability. Laser performance gives you accuracy and faster read rates on virtually any bar code substrate, including colors. When operated by battery, the LT 1804 is ideal for portable data collection.

The LT 1804 weighs 6.0 ounces (170 gm) without the cable and is made from a durable, flame retardant plastic. 1-1

Page 9

LT 1804 Product Reference Guide: Setting Up the LT 1804

Unpacking Remove the LT 1804 from its packing and inspect it for damage. If the scanner was damaged in transit, call the Symbol Support Center at one of the telephone numbers listed on page ii. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.

Connecting Your LT 1804 LT 1804 scanners can be battery operated, or you can use an external power supply. The scanner contains on-board discrete RS-232C communications for connecting to RS-232C asynchronous terminals and host systems. It can also accommodate any of the Synapse™ “Smart Cables” which allows you to connect to a wide variety of host systems. Note: The model number of the adapter cable depends on the host device. See page 3-3.

1-2

Page 10

LT 1804 Product Reference Guide: Setting Up the LT 1804

RS-232 Power Supply Operation 1. Make sure that the host device is powered down before you connect the scanner. 2. Plug the connector at the end of the scanner's straight cable into the appropriate RS-232C receiving port on your host device. 3. Plug one end of the power supply cable into the power supply port on the side of the LT 1804 connector. 4. Connect the power supply to an AC receptacle supplying voltage of the appropriate level.

Power Supply (Standard)

RS-232 Compatible Device (CRT, Etc.)

LT 1804

Figure 1-1. RS-232 Power Supply Operation

1-3

Page 11

LT 1804 Product Reference Guide: Setting Up the LT 1804

RS-232 Battery Operation 1. Insert a 9-volt battery into the battery pack. 2. Plug the 9-pin connector at the end of the scanner's cable into one end of the battery pack. 3. Use the adapter cable to connect the LT 1804 to the host device. Connect one end of this cable to the battery pack and the other to the appropriate port on the host device (either a stationary or portable terminal). 4. If desired, plug one end of the power supply connector into the receptacle on the side of the battery pack. Plug the other end of the connector into an AC outlet. The LT 1804 scanner uses either an alkaline battery or a nickel-cadmium rechargeable battery. Low battery power is signaled by four short, high tone beeps, as well as scanning interruptions. If this occurs, change or recharge the battery as soon as possible.

Power Supply (As Required) Portable Data Terminal Battery Pack

Adapter Cable

Adapter Cable*

LT 1804

*3-foot extension cable is available. Figure 1-2. RS-232 Battery Operation

1-4

Page 12

LT 1804 Product Reference Guide: Setting Up the LT 1804

Changing the Battery 1. Disconnect the battery pack. 2. To open the battery pack, push up on the flanges at one end of the pack. 3. Remove the old battery. 4. Insert the new or recharged 9-volt battery into the battery pack. Match the positive (+) and negative (-) terminals on the battery with the corresponding terminals in the battery pack.

Recharging a Nickel-Cadmium Battery 1. Remove the battery from the battery pack and place it in the recharging unit. 2. To recharge the battery, follow the instructions supplied with the recharging unit. Front View: Belt Goes through Loop on Back of Holster, Battery Pack, and Portable Terminal Holster LT 1804

Back View Portable Terminal

Battery Pack

Scanner Holster

Adapter Cable

5’ Coiled Scanner Cable

Figure 1-3. Portable Operation with Scanner Holster, Battery Pack and Terminal Holster

1-5

Page 13

LT 1804 Product Reference Guide: Setting Up the LT 1804

Synapse Configuration See the Synapse Interface Guide provided with your Synapse cable for setup instructions. Power Supply (As Required)

Host

Synapse “Smart Cable”

Synapse Adapter Cable

Figure 1-4. Synapse Configuration

1-6

LT 1804