Page 14

Chapter 2 Scanning with the LT 1804 Scanning • Be sure the scanner is connected to the controller or portable data terminal before you turn on the system. • Be sure the symbol you want to scan is within the LT 1804 scanning range

(see LT 1804 Decode Zone on page 2-2.) • If the scanner is in triggerless mode, simply bring the scanner to the bar code. The scan beam is in a constant blinking state which becomes steady when the scanner is decoding a bar code. • If the scanner is in triggered mode, bring the scanner to the bar code and press the trigger. The scan beam (and red LED on the top of the scanner) illuminates for approximately 1 second, or until a successful decode. • Your scan beam must cross every bar and space on the symbol. RIGHT

WRONG

012345

012345

• When the symbol has been decoded, a short, high-tone beep sounds and the green decode LED lights.

2-1

Page 15

LT 1804 Product Reference Guide: Scanning with the LT 1804

LT 1804 Decode Zone 3 in 7.62 cm 2.5 in 6.35 cm 2 in 5.08 cm 1.5 in 3.81 cm

.5 in 1.27 cm 0 in 0 cm .5 in 1.27 cm 1 in 2.54 cm 1.5 in 3.81 cm 5.5 mil (0"-.75")

2 in 5.08 cm

6 mil (0" - 1")

2.5 in 6.35 cm

7.5 mil (0" - 2.2")

3 in 7.62 cm

13 mil (0"-5") (100% UPC/EAN)

0 in

.5 in

1 in

1.5 in

2 in

2.5 in

3 in

3.5 in

4 in

4.5 in

5 in

0 cm

1.27 cm

2.54 cm

3.81 cm

5.08 cm

6.35 cm

7.62 cm

8.89 cm

10.16 cm

11.43 cm

12.70 cm

DISTANCE FROM SCANNER

Figure 2-1. LT 1804 Decode Zone

2-2

WIDTH OF FIELD

SCANNER NOSE

1 in 2.54 cm

Page 16

Chapter 3 Maintenance and Specifications Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. • Do not allow any abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a tissue moistened with ammonia/water. • Do not spray water or other cleaning liquids directly into the window. • Do not remove the nose of the scanner.

What If... Nothing happens when you follow the operating instructions. You Should • Check the system power; check the power supply or battery pack connections. • Make sure the controller is programmed to decode bar codes of the symbology you are scanning. • Check for loose cable connections. • Make sure the symbol is not defaced. • Try scanning test symbols of the same code type.

Note: If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Support Center. See page ii for the telephone number. 3-1

Page 17

LT 1804 Product Reference Guide: Maintenance and Specifications

Accessories Standard Accessories: Part Number 70-32537-XX 70-31612-XX 50-11400-007

Description LT 1804 Product Reference Guide LT 1810/1804 Quick Reference Guide Shipping Box

Power Supply Operation: RS-232C Single-Port Straight Cable: Part Number 25-17837-02

Cable Female 9-Pin (TxD on pin 2), with power jack

RS-232C Cable Adapters: Part Number 50-12100-380 50-12100-379 50-12100-378 50-12100-377

Adapter Type 9-Pin to Male 25-Pin (TxD on pin 2) 9-Pin to Male 25-Pin (TxD on pin 3) 9-Pin to Female 25-Pin (TxD on pin 2) 9-Pin to Female 25-Pin (TxD on pin 3)

Power Supplies: Part Number 50-14000-005 50-04000-083

Description 117V Input, 5V Output Power Supply 220/240V Input, 5V Output Power Supply

3-2

Page 18

LT 1804 Product Reference Guide: Maintenance and Specifications

Battery Operation: Part Number 25-09075-01 20-10615-01

Description Straight Cable Battery Box (5V Regulated)

Adapter Cables: Part Number 20-03113-02 20-03114-02 20-03115-02 20-03116-02

Connector Type Male, 25-Pin (TxD on pin 3) Male, 25-Pin (TxD on pin 2) Female, 25-Pin (TxD on pin 3) Female, 25-Pin (TxD on pin 2)

Coiled Extension Cables: Part Number 25-08892-01

Description 3-foot Extension Cable

Synapse Adapter Cables: Part Number 25-31617-01

Description 6-foot Straight Cable

Optional Accessories: LT 1804 optional accessories, supplied at extra cost, include additional units of any item list of Standard Accessories, and the following items. Part Number 20-12769-01 20-08414-01 20-08415-01 21-08288-02 23-08253-01 20-08416-01

Description Hands-Free Stand - Desk Mount (non-adjustable) Hands-Free Stand - Free Standing (adjustable) Hands-Free Stand - ECR Mount (adjustable) Desk-Mount Stand Wall-Mount Stand Holster/Belt Clip

Host interface cable pinouts begin on page 3-7. 3-3

Page 19

LT 1804 Product Reference Guide: Maintenance and Specifications

Technical Specifications Table 3-1. Technical Specifications ITEM

DESCRIPTION

Power Requirements

5 VDC ±10%; 120 mA average current (160 mA peak)

Off Current Stand-By Mode

10 µA

Decode Capability

The LT 1804 scanner can be programmed to decode the following code types: UPC/EAN, UCC/EAN 128, Code 39, Code 39 Full ASCII, Codabar, Interleaved 2 of 5, Code 128, Discrete 2 of 5, and Code 93. Set code length(s) for any 2 of 5 code type. Full autodiscrimination as required.

Beeper Operation

User-selectable: Enable, Disable

Beeper Volume

User-selectable: Full Volume, Low Volume

Decode Depth of Field

Maximum typical working distance is 5.0 in. (12.70 cm) (100% UPC/EAN); minimum element width resolution is 5.5 mils

Scan Repetition Rate

40 (± 3) scans/sec. (bidirectional)

Skew Tolerance

± 35˚ min. (from normal)

Pitch Tolerance

-20° to +60˚ (from normal)

Print Contrast Minimum

25% minimum reflectance differential, measured at 675 nm.

Ambient Light Immunity

Immune to direct exposure to normal office and factory lighting conditions, as well as direct exposure to sunlight.

Durability

5 ft (152 cm) drops to concrete

Operating Temperature

32˚ to 104˚ F (0˚ to 40˚ C)

Storage Temperature

-40˚ to 140˚ F (-40˚ to 60˚ C)

Straight Cable Length

6 ft (183 cm)

Weight (without cable)

6.0 oz. (170 gm)

3-4

Page 20

LT 1804 Product Reference Guide: Maintenance and Specifications

LT 1804 Dimensions Nose Width: 2.8 in (7.1 cm)

Length: 8.0 in (20.3 cm)

Table Height: 2.4 in (6.1 cm)

Handle Width: 2.0 in (5.1 cm)

Height: 1.8 in (4.6 cm)

Figure 3-1. LT 1804 Dimensions 3-5

Page 21

LT 1804 Product Reference Guide: Maintenance and Specifications

LT 1804 Signal Descriptions The following signal descriptions apply to the connection between the scanner and the cable, and are for reference only. Table 3-2. Scanner Cable Pinouts PIN

SIGNAL NAME

FUNCTION

1

DTR

Data Terminal Ready. This signal is hardwired active.

2

VBATT

Input power.

3

GROUND

Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.

4

RxD

Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.

5

RTS

Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be used in conjunction with the CTS line.

6

Synapse Data

Data line for Synapse communication.

7

Synapse Clock

Clock line for Synapse communication.

8

CTS

Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.

10

TxD

Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.

PIN 10

PIN 1

3-6

Page 22

LT 1804 Product Reference Guide: Maintenance and Specifications

Interface Cable Pinouts Table 3-3. 25-Pin Male D-Type Connector 25-06753-01 for power supply version 20-03113-01 for battery pack version PIN

SIGNAL NAME

FUNCTION

2

RxD

Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.

3

TxD

Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.

4

CTS

Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.

5

RTS

Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be used in conjunction with the CTS line.

6

DTR

Data Terminal Ready. This signal is hardwired active.

7

GROUND

Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.

3-7

Page 23

LT 1804 Product Reference Guide: Maintenance and Specifications

Table 3-4. 25-Pin Male D-Type Connector 25-06862-01 for power supply version 20-03114-01 for battery pack version PIN

SIGNAL NAME

FUNCTION

2

TxD

Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.

3

RxD

Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.

4

RTS

Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be used in conjunction with the CTS line.

5

CTS

Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.

7

GROUND

Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.

20

DTR

Data Terminal Ready. This signal is hardwired active.

3-8

Page 24

LT 1804 Product Reference Guide: Maintenance and Specifications

Table 3-5. 25-Pin Female D-Type Connector 25-06860-01 for power supply version 20-03115-01 for battery pack version

PIN

SIGNAL NAME

FUNCTION

2

RxD

Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.

3

TxD

Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.

4

CTS

Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.

5

RTS

Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be used in conjunction with the CTS line.

6

DTR

Data Terminal Ready. This signal is hardwired active.

7

GROUND

Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.

3-9

Page 25

LT 1804 Product Reference Guide: Maintenance and Specifications

Table 3-6. 25-Pin Female D-Type Connector 25-06858-01 for power supply version 20-03116-01 for battery pack version PIN

SIGNAL NAME

FUNCTION

2

TxD

Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.

3

RxD

Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.

4

RTS

Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be used in conjunction with the CTS line.

5

CTS

Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.

7

GROUND

Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.

20

DTR

Data Terminal Ready. This signal is hardwired active.

3-10