Page 26
Chapter 4 Programming the LT 1804 Before programming the scanner, follow the instructions in Chapter 1: Setting Up the LT 1804. If the default values suit your requirements, just scan the SET DEFAULT bar code. An LT 1804 is programmed for parameters other than default values by scanning sequences of bar codes. Chapter 5: Parameter Menus contains all the bar codes necessary to program the scanner for each parameter selection.
Scanning Sequences A scanning sequence establishes a value for one parameter type. During a scanning sequence, scan bar codes for a parameter type, a parameter value, and ENTER. The Scanning Sequence Flowchart on page 4-3 illustrates this process.
Scanning Sequence Examples To program the scanner for all default settings except for two parameters, DECODE UPC ONLY and INTERCHARACTER DELAY, first scan the SET DEFAULT bar code. The default for DECODE UPC ONLY is DISABLED; to enable this, scan the three bar codes in the order listed below: SCAN
YOU WILL HEAR . . .
1. DECODE UPC ONLY
Short high tone
2. ENABLED
Short high tone
3. ENTER
Hi/Lo/Hi/Lo warble
After the last scan in a successful scanning sequence (ENTER), the warble sound (i.e., hi/lo/hi/lo) indicates that the scanner has been successfully programmed for the selected parameter. See Beeper Definitions on page 4-17 for other beeper indications. 4-1
Page 27
LT 1804 Product Reference Guide: Programming the LT 1804
The INTERCHARACTER DELAY default is 00 ms; in this example you want to set it to 2 ms. To program the scanner for a 2 ms INTERCHARACTER DELAY, scan the four bar codes listed below. There are four bar codes because this sequence includes a two digit entry; note that single digit entries must have a leading zero. SCAN
YOU WILL HEAR . . .
1. INTERCHARACTER DELAY
Short high tone
2. 0
Short high tone
3. 2
Short high tone
4. ENTER
Hi/Lo/Hi/Lo warble
Errors While Scanning Don’t worry if you make an error during a scanning sequence. There are two special-purpose bar codes, BACKSPACE and CANCEL, to help you. Scanning the BACKSPACE bar code erases the value of the previous bar code scanned but keeps you within the scanning sequence for a parameter type. Scanning CANCEL removes you from the current sequence so that you can start again.
4-2
Page 28
LT 1804 Product Reference Guide: Programming the LT 1804
Re-Select
START
Re-Select
Incorrect parameter type
CANCEL
SELECT AND SCAN PARAMETER TYPE
GOOD
Re-Select
No Good CANCEL
SELECT AND SCAN (PARAMETER VALUE)
No Good
GOOD
SCAN ENTER (Parameter is Set)
Figure 4-1. Scanning Sequence Flowchart
4-3
BACKSPACE
Page 29
LT 1804 Product Reference Guide: Programming the LT 1804
Parameter Descriptions See Table 4-1 on page 4-13 for the range of values and default settings for each parameter type.
Set Parameter Defaults Scanning the SET DEFAULT bar code returns all parameters to the default values listed in Table 4-1 on page 4-13.
RS-232 Host Type This menu allows you to select one of the following RS-232 host types: Standard RS-232, ICL, Fujitsu, Nixdorf Mode A or Nixdorf Mode B.
Code Types The bar code menu selections enable the scanner to decode any or all of the following symbologies: • UPC Versions A and E (EAN 8 and 13)
• UCC/EAN 128
• Code 39
• Codabar
• Interleaved 2 of 5
• Discrete 2 of 5
• Code 93
• Code 39 Full ASCII
• Code 128
The scanner will autodiscriminate between all of the above symbologies, except for Code 39 and Code 39 Full ASCII. If UPC/EAN with supplemental characters is selected, UPC/EAN without supplemental characters is ignored. See Decode UPC/EAN Supplemental on page 4-6 for details. If you want to add Discrete 2 of 5 or Interleaved 2 of 5, check the previously enabled lengths. To set lengths for these codes, see Fixed Lengths For Code 2 of 5 on page 5-7.
4-4
Page 30
LT 1804 Product Reference Guide: Programming the LT 1804
Fixed Lengths for Code 2 of 5 Select one or two lengths for the Interleaved or Discrete 2 of 5 codes. Determine the number of characters represented in each code type by counting the number of printed (i.e., human readable) digits that represent a bar code label. One length (Length 1) or two lengths (Length 2) for either code type may be set, as needed. If any default setting is in effect and is an appropriate length, it need not be reset. Set one or both lengths, one per scanning sequence. LENGTH 1 may range from 01-31 and LENGTH 2 may range from 00-31.
Decode Options Transmit UPC-E/UPC-A Check Digit Select if decoded UPC-E or UPC-A symbols are transmitted with or without the check digit.
Decode UPC Only (Not EAN) If selected, this option limits LT 1804 UPC/EAN decode capability to UPC versions only. It disables EAN decode capability.
Convert UPC-E to UPC-A Use this parameter to convert UPC-E (zero suppressed) decoded data to UPCA format before transmission. After conversion, data follows UPC format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. In addition to any single-character prefix already selected, the code ID character is appended as a prefix to the decode. Code ID characters are: A = UPC-A, UPC-E, EAN-13, or EAN-8; B = Code 39; C = Codabar; D = Code 128; E = Code 93; F = Interleaved 2 of 5; G = Discrete 2 of 5 or Discrete 2 of 5 IATA; K = UCC/EAN128. Note: This option should not be enabled for ICL, Fujitsu, or Nixdorf RS-232 terminals. See Table 4-3 on page 4-16 for terminal-specific code ID characters for these hosts. 4-5
Page 31
LT 1804 Product Reference Guide: Programming the LT 1804
EAN Zero Extend This parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
I 2 of 5 to EAN-13 Conversion This parameter converts a 14-character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.
CLSI Editing Use this parameter to insert a space after the 1st, 5th, and 10th characters of a 14-character Codabar symbol. The symbol length includes start and stop characters.
NOTIS Editing This option strips the start and stop characters from decoded Codabar symbols.
Decode UPC/EAN Supplemental Select whether UPC/EAN is decoded with or without supplemental characters, or whether the unit will autodiscriminate between the two. Supplementals are additionally appended characters, according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+5). If UPC/EAN with supplemental characters is selected, UPC/EAN symbols without supplemental characters won't be decoded. If UPC/EAN without supplemental characters is selected and the scanner is presented with a UPC/ EAN plus supplemental symbol, the UPC/EAN will be decoded and the supplemental characters ignored. If autodiscrimination is chosen, the LT 1804 will, after additional processing to ensure a good decode, transmit either.
4-6
Page 32
LT 1804 Product Reference Guide: Programming the LT 1804
Beep After Good Decode Determine if the unit beeper will sound during normal scanning. Usually it is desirable to operate the unit with the beeper enabled. In all cases, the beeper operates during parameter menu scanning and indicates error conditions. See Beeper Definitions on page 4-17.
Beeper Volume Use this parameter to program the beeper for Full or Low volume.
Trigger Mode (for triggered models only) Select whether you would like to use the scanner with the trigger (Triggered Mode) for low power consumption, or if you’d like the laser to be in a constant blinking state (Triggerless Mode) using continuous power. The Triggered Mode has been designed for battery operation and is recommended for use with portable terminals.
Decode Redundancy Use this parameter to indicate whether the scanner must read a bar code one time (LEVEL 0), two times (LEVEL 1), or three times (LEVEL 2) before decoding it. A higher level of redundancy ensures the accuracy of a decode in, for example, poor quality symbols.
Scan and Store (Code 39 Buffering) When you select the scan and store option, all Code 39 symbols having a leading space as a first character are temporarily buffered in the unit to be transmitted later. The leading space is not buffered. Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See Code 39 Buffering (Scan and Store) beginning on page 4-19 for further details. When the scan and transmit option is selected, decoded Code 39 symbols without leading spaces are transmitted without being stored in the buffer.
4-7
Page 33
LT 1804 Product Reference Guide: Programming the LT 1804
Scan and Store affects Code 39 decodes only. If you select scan and store, it is recommended that you configure the scanner to decode Code 39 symbology only.
Baud Rate Baud rate is the number of bits of data transmitted per second. The unit's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.
Parity A parity check bit is the most significant bit of each ASCII coded character. If you select ODD parity, the parity bit will have a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. If you select EVEN parity, the parity bit will have a value, 0 or 1, to ensure that an even number of 1 bits are contained in the coded character. Select MARK parity and the parity bit will always be 1. Select SPACE parity and the parity bit will always be 0. Select the parity type according to host device requirements.
Hardware Handshaking Hardware handshaking allows you to check the readiness of the receiving device before data is transmitted. If the receiving device is periodically occupied with other tasks, hardware handshaking is needed to prevent loss of transmitted data. Select whether the scan data is to be transmitted as soon as it is available or whether transmission follows the RTS/CTS procedure. See Communication Protocols on page 4-21 for more details.
Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. These options may be combined, for example ACK/NAK with ENQ. 1. No Software Handshaking
4-8
Page 34
LT 1804 Product Reference Guide: Programming the LT 1804
2. ACK/NAK Only The ACK/NAK option checks the success or failure of transmission. The scanner expects one of the following host responses after a data transmission: <ACK> - Acknowledges a valid and successful transmission. <NAK> - Indicates a problem with the transmission. Whenever a <NAK> is received, the unit retransmits the same data and awaits an ACK/NAK response. After three unsuccessful attempts to transmit the same data, the scanner aborts any further communication attempts on that message. Transmission error is indicated by the unit sounding 4 long beeps. 3. ENQ ONLY The ENQ option needs the host to request data before it is transmitted to the host. This ensures that data transmission occurs only when the host is ready to receive. When you select the wait for ENQ option, the scanner waits for an ENQ, Enquire, character from the host before it transmits data; otherwise, the unit transmits data without waiting for an ENQ character from the host. With ENQ enabled, the scanner must receive an ENQ from the host within a 2 second period after the last activity or 4 long beeps are sounded to indicate a transmission error; the unit is now ready to scan again. 4. ACK/NAK with ENQ This combines both handshaking options.
RTS Line State This parameter is used to set the idle state of the Serial Host RTS line.
Host Serial Response Time-out This parameter specifies how long the scanner waits for an ACK, NAK, or CTS before determining that a transmission error has occurred. This only applies when an ACK/NAK Software Handshaking mode or RTS/CTS Hardware Handshaking option is enabled. The delay period can range from 0.5 to 9.9 seconds in .1-second increments.
4-9
Page 35
LT 1804 Product Reference Guide: Programming the LT 1804
Transmit “No Decode” Character This feature gives you the option to transmit “NR” when a symbol does not decode. Prefixes and suffixes enabled will be appended around this character. Note: This option is available in Triggered Mode only.
Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
Scan Data Transmission Format (Synapse Hosts Only) This parameter formats the data for transmission. Options are: • None (Data As Is) • Prefix/Data • Prefix/Data/Suffix • Data/Suffix.
Prefix (RS-232) The scanner will add one of the following start-of-text characters to transmitted data. • None • Start-of-text <STX> • One user-defined prefix (can be any ASCII character).
Suffix (RS-232) Select one or two end-of-text characters to be added to transmitted data: • None • CR (Carriage Return) - Returns the cursor to the same position on the line after each decode. • LF (Line Feed) - Moves the cursor down a line after each decode.