Page 36

LT 1804 Product Reference Guide: Programming the LT 1804

• CR & LF - Allow you to select where the cursor on a display terminal returns to after it displays each decoded symbol. Selecting both CR & LF, returns the cursor to the same position on successive lines after each decode. If you select no control code, the cursor remains where it stopped after the last transmission. • End-of-text <ETX>. • One or two characters, user-defined.

Prefix/Suffix (Synapse) When using Synapse, the prefix or suffix appended to scan data for data editing is set by scanning a 4-digit number (i.e., 4 bar codes) that corresponds to key codes for various terminals.

Communications Delays and Timeouts (Intercharacter Delay) Select the intercharacter delay option matching host device requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select from no delay to a 99 ms delay between the transmission of each character.

UPC A and E Preamble(s) Three options are given for the lead-in characters of decoded UPC-A or UPCE symbols transmitted to the host device. Select one preamble for UPC-A decodes and one for UPC-E decodes. These lead-in characters are considered part of the symbol itself. The three options are: • a system character only • the country code and system character • no preamble

The system character is the digit printed to the extreme left of a UPC symbol. The country code for UPC is always zero, and it cannot be transmitted without the system character.

4-11

Page 37

LT 1804 Product Reference Guide: Programming the LT 1804

Data Format This parameter sets the transmit data format. The options are: • 7 Data Bits (with Parity) • 8 Data Bits (with Parity) • 8 Data Bits (without Parity)

The PARITY parameter applies only to the 7 Data Bits (with Parity), and 8 Data Bits (with Parity) options.

4-12

Page 38

LT 1804 Product Reference Guide: Programming the LT 1804

Standard Defaults Table 4-1. Parameter Selections PARAMETER

SELECTIONS AVAILABLE

DEFAULT

RS-232 Host Type

Standard RS-232, ICL, Fujitsu, Standard RS-232 Nixdorf Mode A, Nixdorf Mode B

Add Code Types to be Decoded

Code 39, Code 39 Full ASCII, Discrete 2 of 5, Interleaved 2 of 5, Codabar, UPC/EAN, Code 93, Code 128, UCC/EAN128, All Code Types

All Code Types

First Length Discrete 2 of 5

2 digit entry, ranging from 01-31.

12

Second Length Discrete 2 of 5

2 digit entry, ranging from 00-31.

0

First Length Interleaved 2 of 5

2 digit entry, ranging from 01-31.

14

Second Length Interleaved 2 of 5

2 digit entry, ranging from 00-31.

0

Xmit UPC-A Check Digit

Enable, Disable

Enable

Xmit UPC-E Check Digit

Enable, Disable

Enable

Decode UPC Only

Enable, Disable

Disable

Convert UPC-E to A

Enable, Disable

Disable

Xmit Code ID Character

Enable, Disable

Disable

EAN Zero Extend

Enable, Disable

Disable

I 2 of 5 to EAN-13 Conversion

Enable, Disable

Disable

CLSI Editing

Enable, Disable

Disable

NOTIS Editing

Enable, Disable

Disable

UPC/EAN Supplemental

No Supplemental, Supplemental Only, Autodiscriminate

No Supplemental

Beep After Good Decode

Enable, Disable

Enable

Beeper Volume

Low, Full

Full

Trigger Mode (triggered models only)

Triggered, Triggerless

Triggered

Decode Redundancy

Level 0, Level 1, Level 2

Level 0

4-13

Page 39

LT 1804 Product Reference Guide: Programming the LT 1804

Table 4-1. Parameter Selections (Continued) PARAMETER

SELECTIONS AVAILABLE

DEFAULT

Buffer Code 39 Symbols (Scan and Store)

Enable, Disable

Disable

Baud Rate

300, 600, 1200, 2400, 4800, 9600, 19,200

9600

Parity

Even, Odd, Mark, Space

Even

Hardware Handshaking

None, RTS/CTS

None

Software Handshaking

None, ENQ, ACK/NAK, ACK/NAK with ENQ

None

RTS Line State

Low, High

Low

Host Serial Response Timeout

0.5 - 9.9 seconds

2.0 seconds

Stop Bit Select

One, Two

Two

Xmit “No Decode” Character

“NR”, No Character

No Character

Scan Data Format

None, <Prefix><Data>, <Prefix> <Data><Suffix>, <Data><Suffix>

None

Prefix to Decoded Data (RS-232)

None, Start-of-text <STX>, User's Choice (1 selection)

None

Suffix to Decoded Data (RS-232)

None, CR, LF, CR/LF, User's CR/LF Choice (1 selection), User's Choice (2 selections), End-of-text <ETX>

Prefix (Synapse)

Any ASCII Character

CR/LF

Suffix (Synapse)

Any ASCII Character

CR/LF

Intercharacter Delay

00-99 ms

None

UPC-E Preamble

System Character, System Character & Country Code, None

System Character

UPC-A Preamble

System Character, System Character & Country Code, None

System Character

Data Format

7 Data Bits (with Parity), 8 Data Bits (with Parity), 8 Data Bits (without Parity)

7 Data Bits (with Parity)

4-14

Page 40

LT 1804 Product Reference Guide: Programming the LT 1804

RS-232 Host Type Defaults Three RS-232C hosts are set up with their own parameter default settings (Table 4-2.). Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the defaults listed below. These defaults take precedence over standard defaults. So if you select Fujitsu RS-232C, then select the standard defaults, the Fujitsu defaults still take precedence. Table 4-2. Terminal-Specific RS-232C Defaults Parameter

Standard

ICL

FUJITSU

NIXDORF Mode A/ Mode B

Transmit Code ID

No

Yes

Yes

Yes

Data Transmission Format

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Suffix

CR/LF (7013)

CR (1013)

CR (1013)

CR (1013)

Baud Rate

9600

9600

9600

9600

Parity

None

Even

None

Odd

Hardware Handshaking

None

RTS/CTS Option 3

None

RTS/CTS Option 3

Software Handshaking

None

None

None

None

Serial Response Time-out

2 Sec.

9.9 Sec.

2 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

Beep On <BEL>

Disabled

Disabled

Disabled

Disabled

RTS Line State

Low

High

Low

*Low = No data to send

*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.

4-15

Page 41

LT 1804 Product Reference Guide: Programming the LT 1804

RS-232C Code ID Characters Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal enables the transmission of Code ID Characters listed in Table 4-3. These Code ID Characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these terminals. Table 4-3. Terminal Specific Code ID Characters ICL

FUJITSU

NIXDORF

UPC-A

“A”

“A”

“A”

UPC-E

“E”

“E”

“C0”

EAN-8

“FF”

“FF”

“B”

EAN-13

“F”

“F”

“A”

Code 39

“C” <len>

None

“M”

Codabar

“N” <len>

None

“N”

Code 128

“L” <len>

None

“K”

I 2 of 5

“I” <len>

None

“I”

Code 93

None

None

“L”

D 2 of 5

“H” <len>

None

“H”

UCC/EAN 128

“L” <len>

None

“P”

4-16

Page 42

LT 1804 Product Reference Guide: Programming the LT 1804

Beeper Definitions Standard Use BEEPER SEQUENCE

INDICATION

1 Beep - short high tone

A symbol has been successfully decoded.

2 Beeps - long low tone

Undefined host enabled.

4 Beeps - long low tone

Error in transmission; loss of last data scanned. Scan last data again.

4 Beeps - short high tone

Power Supply: Insufficient power condition. Battery Pack: Low voltage indicated. No further scanning is possible. Change or recharge battery.

Parameter Menu Scanning BEEPER SEQUENCE

INDICATION

1 Beep - short high tone

Appropriate menu within the scanning sequence has been read.

1 Beep - warble sound

Parameter value has been entered successfully.

2 Beeps - long low tone

Parameter not entered or incorrect sequence performed. Scan CANCEL and restart the scanning sequence.

4-17

Page 43

LT 1804 Product Reference Guide: Programming the LT 1804

Code 39 Scan and Store BEEPER SEQUENCE

INDICATION

1 Beep - hi/low tone

Indicates new data being entered into the buffer.

1 Beep - short lo/hi/lo tone

The buffer has been erased, or there was an attempt to transmit an empty buffer. When the buffer was empty, the LT 1804 read a command to clear or to transmit a Code 39 buffer.

3 Beeps - long high tone

Code 39 buffer is full.

4 Beeps - long low tone

Error in transmitting stored buffer data.

1 Beep - lo/hi tone

Transmission of stored buffer data is good.

4-18

Page 44

LT 1804 Product Reference Guide: Programming the LT 1804

Code 39 Buffering (Scan and Store) While there is data in the transmission buffer, deleting Code 39 buffering capability via the parameter menu is not allowed. To allow disabling of Code 39 buffering, first force the buffer transmission (see Transmit Buffer) or clear the buffer.

Buffer Data To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space immediately following the start pattern. • Unless symbol overflows the transmission buffer, unit gives hi/lo beep to indicate successful decode and buffering. See Overfilling Transmission Buffer. • Unit adds the message, excluding the leading space to the transmission buffer. • No transmission will occur.

Clear Transmission Buffer To clear the transmission buffer, read a symbol which contains only a start character, a dash (minus), and a stop character, such as the bar code below. • Unit issues a short hi/lo/hi beep to signal that the transmission buffer has been erased, and no transmission has occurred. • Unit erases the transmission buffer. • No transmission will occur.

CLEAR TRANSMISSION BUFFER

4-19

Page 45

LT 1804 Product Reference Guide: Programming the LT 1804

Transmit Buffer To transmit the buffer, read a symbol containing either the first or second condition: 1. Only a start character, a plus (+), and a stop character, such as the bar code below. • The unit signals that the transmission buffer has been sent (a lo/hi beep). • Unit sends the buffer. • Unit clears the buffer.

TRANSMIT BUFFER

2. A Code 39 bar code with leading character other than a space. • The unit signals that a good decode and buffering of that decode has occurred by giving a lo/hi beep. • Unit transmits the buffer. • Unit signals that the buffer has been transmitted.

Overfilling Transmission Buffer If the symbol just read will result in an overflow of the transmission buffer: • Unit indicates that the symbol has been rejected by issuing three long, high beeps. • No transmission will occur.

Attempt to Transmit an Empty Buffer If the symbol just read was the transmit buffer symbol and the Code 39 buffer is empty: • A short lo/hi/lo beep signals that the buffer is empty. • No transmission occurs. • The buffer remains empty. 4-20