Page 36
LT 1804 Product Reference Guide: Programming the LT 1804
• CR & LF - Allow you to select where the cursor on a display terminal returns to after it displays each decoded symbol. Selecting both CR & LF, returns the cursor to the same position on successive lines after each decode. If you select no control code, the cursor remains where it stopped after the last transmission. • End-of-text <ETX>. • One or two characters, user-defined.
Prefix/Suffix (Synapse) When using Synapse, the prefix or suffix appended to scan data for data editing is set by scanning a 4-digit number (i.e., 4 bar codes) that corresponds to key codes for various terminals.
Communications Delays and Timeouts (Intercharacter Delay) Select the intercharacter delay option matching host device requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select from no delay to a 99 ms delay between the transmission of each character.
UPC A and E Preamble(s) Three options are given for the lead-in characters of decoded UPC-A or UPCE symbols transmitted to the host device. Select one preamble for UPC-A decodes and one for UPC-E decodes. These lead-in characters are considered part of the symbol itself. The three options are: • a system character only • the country code and system character • no preamble
The system character is the digit printed to the extreme left of a UPC symbol. The country code for UPC is always zero, and it cannot be transmitted without the system character.
4-11
Page 37
LT 1804 Product Reference Guide: Programming the LT 1804
Data Format This parameter sets the transmit data format. The options are: • 7 Data Bits (with Parity) • 8 Data Bits (with Parity) • 8 Data Bits (without Parity)
The PARITY parameter applies only to the 7 Data Bits (with Parity), and 8 Data Bits (with Parity) options.
4-12
Page 38
LT 1804 Product Reference Guide: Programming the LT 1804
Standard Defaults Table 4-1. Parameter Selections PARAMETER
SELECTIONS AVAILABLE
DEFAULT
RS-232 Host Type
Standard RS-232, ICL, Fujitsu, Standard RS-232 Nixdorf Mode A, Nixdorf Mode B
Add Code Types to be Decoded
Code 39, Code 39 Full ASCII, Discrete 2 of 5, Interleaved 2 of 5, Codabar, UPC/EAN, Code 93, Code 128, UCC/EAN128, All Code Types
All Code Types
First Length Discrete 2 of 5
2 digit entry, ranging from 01-31.
12
Second Length Discrete 2 of 5
2 digit entry, ranging from 00-31.
0
First Length Interleaved 2 of 5
2 digit entry, ranging from 01-31.
14
Second Length Interleaved 2 of 5
2 digit entry, ranging from 00-31.
0
Xmit UPC-A Check Digit
Enable, Disable
Enable
Xmit UPC-E Check Digit
Enable, Disable
Enable
Decode UPC Only
Enable, Disable
Disable
Convert UPC-E to A
Enable, Disable
Disable
Xmit Code ID Character
Enable, Disable
Disable
EAN Zero Extend
Enable, Disable
Disable
I 2 of 5 to EAN-13 Conversion
Enable, Disable
Disable
CLSI Editing
Enable, Disable
Disable
NOTIS Editing
Enable, Disable
Disable
UPC/EAN Supplemental
No Supplemental, Supplemental Only, Autodiscriminate
No Supplemental
Beep After Good Decode
Enable, Disable
Enable
Beeper Volume
Low, Full
Full
Trigger Mode (triggered models only)
Triggered, Triggerless
Triggered
Decode Redundancy
Level 0, Level 1, Level 2
Level 0
4-13
Page 39
LT 1804 Product Reference Guide: Programming the LT 1804
Table 4-1. Parameter Selections (Continued) PARAMETER
SELECTIONS AVAILABLE
DEFAULT
Buffer Code 39 Symbols (Scan and Store)
Enable, Disable
Disable
Baud Rate
300, 600, 1200, 2400, 4800, 9600, 19,200
9600
Parity
Even, Odd, Mark, Space
Even
Hardware Handshaking
None, RTS/CTS
None
Software Handshaking
None, ENQ, ACK/NAK, ACK/NAK with ENQ
None
RTS Line State
Low, High
Low
Host Serial Response Timeout
0.5 - 9.9 seconds
2.0 seconds
Stop Bit Select
One, Two
Two
Xmit “No Decode” Character
“NR”, No Character
No Character
Scan Data Format
None, <Prefix><Data>, <Prefix> <Data><Suffix>, <Data><Suffix>
None
Prefix to Decoded Data (RS-232)
None, Start-of-text <STX>, User's Choice (1 selection)
None
Suffix to Decoded Data (RS-232)
None, CR, LF, CR/LF, User's CR/LF Choice (1 selection), User's Choice (2 selections), End-of-text <ETX>
Prefix (Synapse)
Any ASCII Character
CR/LF
Suffix (Synapse)
Any ASCII Character
CR/LF
Intercharacter Delay
00-99 ms
None
UPC-E Preamble
System Character, System Character & Country Code, None
System Character
UPC-A Preamble
System Character, System Character & Country Code, None
System Character
Data Format
7 Data Bits (with Parity), 8 Data Bits (with Parity), 8 Data Bits (without Parity)
7 Data Bits (with Parity)
4-14
Page 40
LT 1804 Product Reference Guide: Programming the LT 1804
RS-232 Host Type Defaults Three RS-232C hosts are set up with their own parameter default settings (Table 4-2.). Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the defaults listed below. These defaults take precedence over standard defaults. So if you select Fujitsu RS-232C, then select the standard defaults, the Fujitsu defaults still take precedence. Table 4-2. Terminal-Specific RS-232C Defaults Parameter
Standard
ICL
FUJITSU
NIXDORF Mode A/ Mode B
Transmit Code ID
No
Yes
Yes
Yes
Data Transmission Format
Data as is
Data/Suffix
Data/Suffix
Data/Suffix
Suffix
CR/LF (7013)
CR (1013)
CR (1013)
CR (1013)
Baud Rate
9600
9600
9600
9600
Parity
None
Even
None
Odd
Hardware Handshaking
None
RTS/CTS Option 3
None
RTS/CTS Option 3
Software Handshaking
None
None
None
None
Serial Response Time-out
2 Sec.
9.9 Sec.
2 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
Beep On <BEL>
Disabled
Disabled
Disabled
Disabled
RTS Line State
Low
High
Low
*Low = No data to send
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
4-15
Page 41
LT 1804 Product Reference Guide: Programming the LT 1804
RS-232C Code ID Characters Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal enables the transmission of Code ID Characters listed in Table 4-3. These Code ID Characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these terminals. Table 4-3. Terminal Specific Code ID Characters ICL
FUJITSU
NIXDORF
UPC-A
“A”
“A”
“A”
UPC-E
“E”
“E”
“C0”
EAN-8
“FF”
“FF”
“B”
EAN-13
“F”
“F”
“A”
Code 39
“C” <len>
None
“M”
Codabar
“N” <len>
None
“N”
Code 128
“L” <len>
None
“K”
I 2 of 5
“I” <len>
None
“I”
Code 93
None
None
“L”
D 2 of 5
“H” <len>
None
“H”
UCC/EAN 128
“L” <len>
None
“P”
4-16
Page 42
LT 1804 Product Reference Guide: Programming the LT 1804
Beeper Definitions Standard Use BEEPER SEQUENCE
INDICATION
1 Beep - short high tone
A symbol has been successfully decoded.
2 Beeps - long low tone
Undefined host enabled.
4 Beeps - long low tone
Error in transmission; loss of last data scanned. Scan last data again.
4 Beeps - short high tone
Power Supply: Insufficient power condition. Battery Pack: Low voltage indicated. No further scanning is possible. Change or recharge battery.
Parameter Menu Scanning BEEPER SEQUENCE
INDICATION
1 Beep - short high tone
Appropriate menu within the scanning sequence has been read.
1 Beep - warble sound
Parameter value has been entered successfully.
2 Beeps - long low tone
Parameter not entered or incorrect sequence performed. Scan CANCEL and restart the scanning sequence.
4-17
Page 43
LT 1804 Product Reference Guide: Programming the LT 1804
Code 39 Scan and Store BEEPER SEQUENCE
INDICATION
1 Beep - hi/low tone
Indicates new data being entered into the buffer.
1 Beep - short lo/hi/lo tone
The buffer has been erased, or there was an attempt to transmit an empty buffer. When the buffer was empty, the LT 1804 read a command to clear or to transmit a Code 39 buffer.
3 Beeps - long high tone
Code 39 buffer is full.
4 Beeps - long low tone
Error in transmitting stored buffer data.
1 Beep - lo/hi tone
Transmission of stored buffer data is good.
4-18
Page 44
LT 1804 Product Reference Guide: Programming the LT 1804
Code 39 Buffering (Scan and Store) While there is data in the transmission buffer, deleting Code 39 buffering capability via the parameter menu is not allowed. To allow disabling of Code 39 buffering, first force the buffer transmission (see Transmit Buffer) or clear the buffer.
Buffer Data To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space immediately following the start pattern. • Unless symbol overflows the transmission buffer, unit gives hi/lo beep to indicate successful decode and buffering. See Overfilling Transmission Buffer. • Unit adds the message, excluding the leading space to the transmission buffer. • No transmission will occur.
Clear Transmission Buffer To clear the transmission buffer, read a symbol which contains only a start character, a dash (minus), and a stop character, such as the bar code below. • Unit issues a short hi/lo/hi beep to signal that the transmission buffer has been erased, and no transmission has occurred. • Unit erases the transmission buffer. • No transmission will occur.
CLEAR TRANSMISSION BUFFER
4-19
Page 45
LT 1804 Product Reference Guide: Programming the LT 1804
Transmit Buffer To transmit the buffer, read a symbol containing either the first or second condition: 1. Only a start character, a plus (+), and a stop character, such as the bar code below. • The unit signals that the transmission buffer has been sent (a lo/hi beep). • Unit sends the buffer. • Unit clears the buffer.
TRANSMIT BUFFER
2. A Code 39 bar code with leading character other than a space. • The unit signals that a good decode and buffering of that decode has occurred by giving a lo/hi beep. • Unit transmits the buffer. • Unit signals that the buffer has been transmitted.
Overfilling Transmission Buffer If the symbol just read will result in an overflow of the transmission buffer: • Unit indicates that the symbol has been rejected by issuing three long, high beeps. • No transmission will occur.
Attempt to Transmit an Empty Buffer If the symbol just read was the transmit buffer symbol and the Code 39 buffer is empty: • A short lo/hi/lo beep signals that the buffer is empty. • No transmission occurs. • The buffer remains empty. 4-20