Manual · Opticon
User's Manual LPN5627, LPR5627 (Raster) Miniature High Speed Laser Fixed Position Scanner
Manual67 pagesPDF 492 KB
User's manual for the Opticon LPN5627 and LPR5627 (raster) miniature fixed position laser scanners: specifications, mounting and programming.
Covers · 1 model
The models it covers
Summary
What is in it
User's manual for the Opticon LPN5627 and LPR5627 (raster) miniature 500 scan per second laser bar code readers built into host equipment. It gives a quick start-up procedure, physical, optical, electrical, RS232 and environmental specifications, connector pin-outs and ordering information, then advice on positioning the scanner for best reading, configuration and default settings, common causes of poor performance, laser labels, maintenance, and appendices of computer and bar code programming commands, dimensional drawings and optical performance.
Its parts
- Section 1 Introduction and Getting Started
- Section 2 Technical Specifications
- Section 3 Positioning the Scanner
- Section 4 Configuring the Scanner
- Section 5 Application Engineering Support
- Section 6 Laser Labeling
- Section 7 Service and Maintenance
From the manual
Key facts from this manual
Each line names its page in the PDF.
Opticon's user's manual 25-ULPNR101-03 (February 2003) for the LPN5627 and LPR5627 (raster) miniature high speed laser fixed position scanners, built into host equipment. It gives the specifications and connector signals, explains how to position the scanner and test its read rate, and shows how to program it by RS232 commands or programming bar codes.
- Device
- Miniature laser fixed position bar code scanner made to be built into host equipment; the LPR5627 is the raster version p. 1, 5
- Interface
- RS232 on a 9-pin male MiniDIN connector p. 6, 9
- Power
- +5VDC; 150mA idle, 350 mA max. with the laser on p. 9
- Default serial settings
- 9600 baud, 8 data bits, 1 stop bit, no parity, no handshaking p. 5, 17
- Serial options
- 300 to 38,400 baud; 7 or 8 data bits; odd, even or no parity; hardware, software or no handshaking p. 9
- Symbologies
- Codabar (NW-7), Code 39, Code 93, Code 128, Industrial 2 of 5, Interleaved 2 of 5, MSI/Plessey, WPC (UPC/EAN/JAN), IATA p. 6
- Light source
- 650 ±10nm visible laser diode p. 6
- Focal distance
- About 4.0 in. from the front edge of the scanner p. 11
- Size and weight
- 1.9 x 1.5 x 0.9 in (WxDxH) (47.4 x 37.2 x 23 mm); 2.9 oz (80 grams) without cable p. 6
- Case and mounting
- Zinc die cast case with 2 threaded (M-3) mounting holes p. 6
- Connector signals
- Trigger, Good Read, Bad Read, CTS, RTS, RD, SD, +5V and signal ground p. 9
- Part numbers
- LPN5627RR1S-048 and LPR5627RR1S-048, where -048 is the standard configuration p. 10
- Evaluation kits
- LPN-5627R101-SK1, and LPR-5627R101-SK1 for the raster version: scanner, test and evaluation board, 5V power supply, extension cable, manual p. 10
- Programming
- RS232 commands in the form <ESC> command <CR>, or programming bar codes; Z2 saves settings p. 17, 21
What this manual walks you through
- Getting started with the evaluation board and a PC terminal program p. 5
- Positioning the scanner for focal distance and depth of field p. 11, 12
- Avoiding specular reflection p. 12, 13
- Measuring performance with the Read Rate Test p. 13, 14
- Setting up for high throughput or for data integrity p. 15
- Reporting a missing or unreadable bar code in trigger enabled mode p. 16
- Programming by computer commands or by bar codes p. 21
- Resetting the scanner to factory defaults p. 22
- Finding the common causes of poor scanning performance p. 18
- Cleaning the scanner p. 19
Good to know
- The manual states the scanners are classified as CDRH Class II laser devices; avoid staring into the beam. p. 19
- There are no user serviceable parts inside, and opening the scanner could expose the operator to laser light. p. 19
- Mounting screws must not extend more than 3 mm into the case. p. 6
- Do not clean with bleach, full or diluted. p. 19
- Equipment the scanner is built into should carry a laser safety label and an indicator lit while the laser emits. p. 19
Questions this manual answers
What power does the Opticon LPN5627 need?
+5VDC, drawing 150mA idle and up to 350 mA with the laser on. p. 9
What are the LPN5627 default serial settings?
9600 baud, 8 data bits, 1 stop bit, no parity and no handshaking. p. 17
How do I reset the LPN5627 to factory defaults?
Scan the Reset All Defaults bar code or send the U1 command; this erases all earlier changes. p. 22
How do I check that the LPN5627 is talking to my PC?
Send <Escape> V5 <Carriage Return> in capital letters; the buzzer sounds when communication works. p. 5
The whole text · 7 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file