Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 7

User's Manual LPN5627, LPR5627 (Raster) Miniature High Speed Laser Fixed Position Scanner, pages 1 to 10

Pages 1 to 10 of 67

The original document is the PDF (492 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Opticon LPN-5627

Page 1

User’s Manual

LPN5627, LPR5627 (Raster)

Miniature High Speed Laser Fixed Position Scanner Manual No. 25-ULPNR101-03 February, 2003

8 Olympic Drive Orangeburg, NY 10962 Tel 845.365.0090 Fax 845.365.1251 www.OpticonUSA.com

Downloaded from www.Manualslib.com manuals search engine

Page 2

Downloaded from www.Manualslib.com manuals search engine

Page 3

Contents Section 1 Introduction and Getting Started Product Overview Quick Start-Up Procedure

1 1 1

Section 2 Technical Specifications Physical Specifications Symbologies Supported Optical Specification Pitch Skew Tilt (rotation) Curvature LPR5627 Raster Pattern Electrical Specification RS232 Communications Specifications Connector Pin Outs Environmental Specifications Ordering Information

2 2 2 2 3 3 3 4 4 5 5 5 6 6

Section 3 Positioning the Scanner Achieving Optimum Performance Measuring Scanner Performance The Read Rate Test Tips for Achieving High Throughput Tips for Insuring Highest Data Integrity Tips for Verifying the Presence of a Bar Code

7 7 9 9 11 11 12

Section 4 Configuring the Scanner Configuring the Scanner Default Setting

13 13 13

Section 5 Application Engineering Support Common Causes of Poor Performance

14 14

Section 6 Laser Labeling

15

Section 7 Service and Maintenance

15

Appendix A How to Program the Scanner

17

Appendix B Computer Programming Commands

19

Appendix C Bar Code Programming Commands

24

Appendix D Dimensional Drawings

61

Appendix E Optical Performance

62

Downloaded from www.Manualslib.com manuals search engine

Page 4

Organization of this Manual This manual provides the necessary instructions for installing and using the Opticon LPN5627 and LPR5627 Fixed Position Scanners. The manual is organized as follows:

Section 1

Introduction and Getting Started Describes the general operation of the LPN5627 and LPR5627 scanners. Also provides a Quick Start-Up Procedure that allows you to begin using the scanner immediately.

Section 2

Technical Specifications Provides complete specifications, including mechanical details, optical performance, RS232 communications and other technical data.

Section 3

Positioning the Scanner for Optimum Performance Provides detailed instructions and tips for mounting and positioning the scanning to obtain the best scanning performance. Application Notes describe guidelines for maximizing specific characteristics.

Section 4

Configuring the Scanner Describes how various parameters can be programmed to customize the scanner for your specific application.

Section 5

Application Engineering Support Discusses the most common questions and concerns when adapting the LPN5627 and LPR5627 scanners in your application.

Section 6

Scanner Labels Discusses the various labels on the product required by CDRH.

Section 7

Scanner Servicing and Maintenance Discusses maintenance and cleaning procedures.

Appendix A Appendix B Appendix C Appendix D Appendix E

How to Program the Scanner Computer Programming Commands Bar Code Programming Commands Dimensional Drawing Optical Performance

Downloaded from www.Manualslib.com manuals search engine

Page 5

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

Section 1 Introduction and Getting Started Product Overview The LPN5627 and LPR5627 (Raster) Fixed Position Scanners are miniature, 500 scan per second, laser bar code readers designed to be easily incorporated into host equipment. The high scan speed and small physical size make the scanner easy to integrate into any hardware design. Durability and reliability are assured. Advanced microprocessor technology coupled with Opticon’s proven decoding algorithms result in high speed operation with superior accuracy. The scanners are fully programmable allowing the user to customize parameters including changing communication settings, selecting symbologies, adding prefixes and appending suffixes. Programmable settings can be downloaded from the host CPU or computer directly to the scanner. The scanners are encased in compact, rugged metal enclosures. The compact size permits installation in the tightest areas allowing great flexibility in mounting and positioning the scanner for optimum performance.

Quick Start-Up Procedure This section is for those who wish to start using the scanner before reading the complete manual. Only a few steps are needed to make the scanner operable. ‰

A Developers Evaluation and Test board is available to allow rapid installation of the scanner

‰

Connect the scanner min-DIN connector to the board

‰

Using the DB9 extension cable, connect the board to a DB9 serial port, such as COM 1 on you PC.

‰

Be sure your PC or host device is running an application such as HyperTerminal that will accept serial input.

‰

The default communications parameters of the scanner are 9600 baud, 1 Start/Stop Bit, 8 Data bits, No Parity, No Handshaking, No Flow Control) See Users Manual for details on establishing or changing communications parameters.

‰

Plug the 5V DC power supply into the jack on the board

‰

There is a trigger test button on the scanner. There is a trigger button on the Evaluation and Test board as well.

That’s it. Your PC and the scanner should now communicate. To verify that the scanner and the PC are communicating properly, send the following command from your PC keyboard to activate the scanner’s buzzer. Send the command: <Escape> V5 <Carriage Return> Note: Be sure to use capital letters, e.g. “V5”, not “v5”. The buzzer should sound, indicating that good communications have been established To test the scanner, press the trigger test button on the scanner itself or on the evaluation board. A red laser light will be visible. Do not stare into the laser light. Page 1 Downloaded from www.Manualslib.com manuals search engine

Page 6

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

This Quick Start-Up procedure will get you started. However, to best understand the full capabilities of this scanner, you should read the complete manual.

Section 2 Technical Specifications Physical Specifications Case Material Dimensions Weight Cable Length Connector Mounting

Zinc-die cast 1.9 x 1.5 x 0.9 in (WxDxH) (47.4 x 37.2 x 23 mm) 2.9 oz (80 grams ) w/o cable 6.5 Feet (2000 mm) 9-pin Male MiniDIN connector 2 threaded (M-3) mounting holes (not to extend more than 3 mm into the case)

Symbologies Supported ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦

Codabar (NW-7) Code 39 Code 93 Code 128 Industrial 2 of 5Interleaved 2 of 5 MSI / Plessey WPC (UPC / EAN / JAN) IATA

Optical Specifications Scan Rate Light source Narrow Bar Resolution Minimum PCS

500 scans per second ±10% 650 ±10nm visible laser diode 6 mil (0.15mm) at 0.9 PCS 0.45 (min. background reflectance of 70%)

Reading Distances LPN5627 (Specification) * Near Bar Code Density Distance 40 mil (1.00 mm) 2.3” 20 mil (0.50 mm) 2.3” 10 mil (0.25 mm) 2.3” 6 mil (0.15 mm) 3.5” * measured from front edge of scanner

Far Distance 12.6” 10.8” 7.5” 4.7”

Reading Distances LPR5627 (Raster – Specification) * Near Bar Code Density Distance 40 mil (1.00 mm) 2.3” 20 mil (0.50 mm) 2.3” 10 mil (0.25 mm) 2.3” 6 mil (0.15 mm) 3.5” * measured from front edge of scanner

Far Distance 10.6” 9.1” 6.7” 4.3”

Page 2 Downloaded from www.Manualslib.com manuals search engine

Page 7

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

Pitch

Hatched No-Read Specular Zone +5 ° Height of barcode

- 10 °

Recommended operation (α) at + 60 degrees or less Avoid specular reflection in the dead zone (hatched).

Skew

β = 0 to 6°

Recommended operation (β) + 25 degrees (h = 35.4 mm, = 10°, α2 θ = 0°, R = ∞)

Tilt (Rotation)

θ θ

BCD

Recommended operation (θ) + 25 degrees (Barcode aspect ratio allowing laser to cover all bars). Page 3 Downloaded from www.Manualslib.com manuals search engine

Page 8

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

Curvature

Jan 13: R = 20 mm (0.8”) or h

R

JAN 13: R = 30 mm (1.2" ) or Jan 8: = 15 JAN 8: RR= 20 mm mm(0.6”). (0.8") or h 35.4 Where: PCS 0.9, Where: PCS 0.9, h ==100 mm, α2 = 10°,β = 0°, θ= 0° Pitch=15°, Skew=0°, Tilt=0°

LPR5627 Raster Pattern

Raster sweep pattern as seen from front of scanner Subtends a 1° angle from top to bottom of raster (at the centerline) as measured from the scanner.

Page 4 Downloaded from www.Manualslib.com manuals search engine

Page 9

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

Electrical Specifications Operating Voltage Current Operating Surge

+5VDC + 10% 150mA idle; 350 mA max. (Laser ON) 2.5 A max.

RS232 Communications Specifications RS232 Data Transmission Format Parameter Timing No. of Start Bits No. of Stop Bits No of Data Bits Parity Baud Rate Handshaking

Default Asynchronous 1 bit 1 bit 8 bit None 9600 baud None

Optional Settings 1 or 2 bits 7 or 8 bits Odd / Even / None 300 to 38,400 baud Hardware / Software/ None

RS232 Transmit / Receive Character Format TXD/ RXD

Start Bit

LSB

7 or 8 Data Bits

MSB

Parity Bit

Stop Bit

RS232 Data Format Transmit Receive

Decoded Data ESC Command STX Command

CR CR ETX

RS232 Signal Level Signal Name TXD RXD

In / Out Out In

Mark/Off -5 to -15 -3 to -15

Space/On +5 to +15 +3 to +15

Signal Trigger Good Read Bad Read CTS RTS RD SD +5V Signal Ground

Color Brown Yellow Orange Blue Gray White Green Red Black

Direction Input Output Output Input Output -

Connector Pin-outs 9 pin Male Mini-Din Connector Pin No. 1 2* 3* 4 5 6 7 8 9

-

* NPN open collector, rated at 24 VDC, 30 mA maximum Page 5 Downloaded from www.Manualslib.com manuals search engine

Page 10

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

Environmental Specifications Temperature Operating Storage

+32 to +113° F (0° to +45° C ) +14 to +140° F (-10° to +60° C)

Humidity (non- condensing) Operating 20 to 85% Storage 20 to 90% Dust/Water

Designed to meet IP54

Ambient Light

Fluorescent or incandescent: below 5 kilolux

Ordering Information Part No. LPN5627RR1S-048* LPR5627RR1S-048*

Model Front View (Linear) Front View (Raster)

* Where "-048" is standard configuration. Other configurations are available as required. Developer’s Test and Evaluation Kits (LPN-5627R101-SK1 and for the raster configuration LPR-5627R101-SK1) are available that contain all the items needed to install and evaluate the scanners. These kits include: ‰

Scanner

‰

Engineering Test & Evaluation Board

‰

5V Power Supply

‰

Extension Cable

‰

User Manual