The text of a manual · part 6 of 7
User's Manual LPN5627, LPR5627 (Raster) Miniature High Speed Laser Fixed Position Scanner, pages 51 to 60
Pages 51 to 60 of 67
The original document is the PDF (492 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Opticon LPN-5627
Page 51
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
18. Disable Number of Characters/Digits Transmitted (continued) Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
2N
Code 128
-3O-
2O
MSI/Plessey
-3P-
2P
IATA
-3Q-
2Z
Do not transmit data length (all symbologies)
-3[-
19. Communication Parameters Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
K1
300 Baud *
-L2-
K2
600 Baud *
-L3-
K3
1,200 Baud *
-L!-
K4
2,400 Baud *
-L5-
K5
4,800 Baud *
-L6-
K6
9,600 Baud
-L7- %
* Use Z2 Command after computer command to store settings in memory prior to power off. CONTINUED ON NEXT PAGE…
Page 47 Downloaded from www.Manualslib.com manuals search engine
Page 52
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
19. Communication Parameters (continued) Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
K7
19,200 Baud *
-L8-
K8
38,400 Baud *
-L9-
L0
7 Data Bits *
-M1-
L1
8 Data bits *
L2
Parity = None
L3
Parity = Even *
-M!-
L4
Parity = Odd *
-M5-
L5
1 Stop Bit *
-M6- %
L6
2 Stop Bits *
-M7-
-M2- % -M3- %
* Use Z2 Command after computer command to store settings in memory prior to power off.
Page 48 Downloaded from www.Manualslib.com manuals search engine
Page 53
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
20. Handshaking Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
I0
Wait for CTS from terminal = Unlimited
-J1-
I1
Wait for CTS from terminal = 100 mS
-J2-
I2
Wait for CTS from terminal = 200 mS
-J3-
I3
Wait for CTS from terminal = 400 mS
-J!-
I4
ACK/NAK Delay Time Unlimited
-J5-
I5
ACK/NAK Delay Time = 100 mS
-J6-
I6
ACK/NAK Delay Time = 500 mS
-J7-
I7
ACK/NAK Delay Time = 1000 mS
-J8-
P0
No Handshaking * (Factory Set)
-Q1- %
P1
Busy/Ready *
-Q2-
P2
Modem *
-Q3-
P3
ACK/NAK *
-Q!-
P4
ACK / NAK no buzzer response on timeout*
-Q5-
P5
No ACK/NAK *
-Q6-
* Use Z2 Computer Command to store in memory prior to power off. Page 49 Downloaded from www.Manualslib.com manuals search engine
Page 54
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
21. Buzzer Operation Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
T0
Volume = Maximum
-U1- %
T1
Volume = Upper Mid-range
-U2-
T2
Volume = Lower Mid-range
-U3-
T3
Volume = Minimum
-U!-
V5
Ring buzzer once at 3kHz for 200 mS
-W6-
V6
Ring buzzer once at 3kHz, 2kHz interval for 200 mS
-W7-
V7
Ring buzzer once at 2kHz, 3kHz interval for 200 mS
-W8-
W0
Disable buzzer
-X1-
W1
Enable buzzer at 3kHz
-X2-
W2
Enable buzzer at 3kHz with 2.5kHz interval
-X3- %
W3
Enable buzzer at 2kHz with 3kHz interval
-X!-
W4
Buzzer duration 0.10 sec
-X5CONTINUED ON NEXT PAGE…
Page 50 Downloaded from www.Manualslib.com manuals search engine
Page 55
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
21. Buzzer Operation (continued) Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
W5
Buzzer duration 0.20 sec
-X6- %
W6
Buzzer duration 0.40 sec
-X7-
W7
Buzzer duration 0.05 sec
-X8-
W8
Buzzer duration 0.01 sec
-X9-
Page 51 Downloaded from www.Manualslib.com manuals search engine
Page 56
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
22. Positive & Negative Bar Codes Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
V4
Positive bar code only (black bars/white spaces)
-W3-
V2
Both positive & negative bar code
-W5- %
23. Setting the Trigger Function Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
S7
Disable the trigger function / Red scanning light is ON continuously (Factory Set)
-T8-
S8
Enable the trigger function /Red scanning light is OFF until trigger is activated or “pulled”
-T9- %
Z
Activate the trigger; turns on the red scanning light
Use Computer Command
The Trigger function is disabled in the default setting. This means that the red scanning light is “ON” continuously and the scanner is always ready to read. For some applications, you may wish to activate the scanner only at a specific time. This can be done by enabling the Trigger function. Once in the “Trigger Enabled” mode, the red scanning light is OFF until the trigger is activated or “pulled.” Either a hardware trigger or a software trigger pulse may be used to activate the scanner. The hardware trigger is actuated by pulling Pin #1 (on the standard 9-pin mini-DIN connector) LOW. The software trigger is actuated by downloading and <ESC> Z <CR> computer command from the host. (See Scanner Timeout to establish the length of time the scanning light remains ON after the trigger is activated.)
Page 52 Downloaded from www.Manualslib.com manuals search engine
Page 57
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
24. Selecting the Read Mode Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
S0
Single Read Mode (Trigger enabled mode only)
-T1-
S1
Multiple Read Mode
S2
Continuous Read Mode
7H
Does not allow first bar distortion
7I
Allow first bar distortion *
7O
Normal Scan
-8P- %
7P
Slanted Scan
-8Q-
7Y
Regular expression up to 5 labels
-8Z-
-T2- % -T3-8I- % -8J-
* Relaxes tolerance on first bar, increasing to 8x narrow bar width on first bar. Decoding time may be increased. CONTINUED ON NEXT PAGE...
Page 53 Downloaded from www.Manualslib.com manuals search engine
Page 58
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
24. Selecting the Read Mode (continued) The operation of the scanner in the various read modes is described in the table below. The “Continuous Read” mode is helpful in positioning the scanner for optimum reading. In “Continuous Read,” the scanner’s buzzer functions like a Geiger counter, sounding the most active at the position achieving the greatest number of good reads. Mode
Trigger Function Enabled Trigger Function Disabled After receiving a trigger pulse, Scanner will read different bar codes scanner will read multiple, in succession if they are presented to different bar codes in succession the read window. Multiple until it times out. Read Scanner will not read the same Scanner will not read the same bar bar code twice if they are code twice if they are consecutive. consecutive. Scanner will read the same bar Continuous code continuously after receiving Scanner will read the same bar code Read a trigger pulse until scanner continuously. times out. Scanner will read only one bar Single code after receiving a trigger Same as Multiple Read mode, above. Read pulse.
Page 54 Downloaded from www.Manualslib.com manuals search engine
Page 59
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
25. Scanner Timeout (Trigger Enabled Mode only) These commands, which are only applicable in the Trigger Enabled mode, establish the time-out period after the trigger pulse is received. The Time-out period is the same whether the scanner is operating in Single, Multiple or Continuous Read mode. Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
Y0
Trigger remains ON as long as trigger is pulled (hardware trigger only)
-Z1-
Y1
1 Second after triggering
-Z2-
Y2
2 Seconds after triggering
-Z3- %
Y3
3 Seconds after triggering
-Z!-
Y4
4 Seconds after triggering
-Z5-
Y5
6 Seconds after triggering
-Z6-
Y6
8 Seconds after triggering
-Z7-
Y7
10 Seconds after triggering
-Z8-
Page 55 Downloaded from www.Manualslib.com manuals search engine
Page 60
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
26. Redundant Decoding The Number of Redundant Decodes determines how many times the scanner must decode a bar code and obtain the same value before it will transmit the data. For example, if the redundancy is set at three times, the scanner will not transmit data until it has decoded the bar code and obtained the same values three times in succession. If it obtains the same value twice in a row, but a different value on the third read attempt, it will not transmit. If it gets the same value three out of four times, it will not transmit. It must receive three consecutive, identical reads. Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
X0
Read bar code once
-Y1-
X1
Read bar code twice
-Y2- %
X2
Read bar code three times
-Y3-
X3
Read bar code four times
-Y!-
7R
Read bar code five times
-8S-
7S
Read bar code six times
-8T-
Page 56 Downloaded from www.Manualslib.com manuals search engine