Page 61
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
27. Transmitting Error Indications (Trigger Enabled only) Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
5E
Do not transmit error code
-6F- %
5F
Transmit “BR” <CR> for bad read or no read
-6G-
5G
Transmit <STX>“>”<ETX> for bad read; <STX>“?”<ETX> for no read
-6H-
5H
Transmit “>”<CR> for bad read Transmit “?”<CR> for no read
-6I-
5I
Transmit “CAN”<CR> for bad read or no read
-6J-
5J
Transmit <STX>“CAN”<ETX> for bad read or no read
-6K-
28. Print Quality Adjustments Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
X4
For lower density, poor print quality bar code, e.g., dot matrix with voids (low analog gain)
-Y5-
X5
For high density, good print quality bar code without voids (high analog gain)
-Y6-
X6
Output data obtained from Low or High analog gain
-Y7- %
X7
Output data obtained from Low and High analog gain
-Y8-
Page 57 Downloaded from www.Manualslib.com manuals search engine
Page 62
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
29. Good Read LED Operation Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
T4
Good read LED disabled after decode
-U5-
T8
Good read LED ON after decode for .10 seconds
-U9-
T5
Good read LED ON after decode for .20 seconds
-U6- %
T6
Good read LED ON after decode for .40 seconds
-U7-
T7
Good read LED ON after decode for .80 seconds
-U8-
V0
LED ON Red for .40 seconds
-W1-
V1
LED ON Red for .80 seconds
-W2-
V8
LED ON Green for .40 seconds
-W9-
V9
LED ON Green for .80 seconds
-W:-
Page 58 Downloaded from www.Manualslib.com manuals search engine
Page 63
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
30. Sequencer Controls Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
8A
Trigger Input (sync signal positive logic) High active
-9B-
8B
Trigger Input (sync signal negative logic) Low Active
8C
Sequencer output synchronous transmission (negative true logic)*
-9C- % -9D- %
8D
Sequencer output synchronous transmission * (positve – true logic)
-9E-
8E
Sequencer output one-shot transmission *
-9F-
8F
Sequencer output one-shot transmission * (negative – true logic)
-9G-
8G
Sequencer output one-shot duration 10 mS
-9H-
8H
Sequencer output one-shot duration 20 mS
-9I-
8I
Sequencer output one-shot duration 30 mS
-9J-
8J
Sequencer output one-shot duration 40 mS
-9K-
8K
Sequencer output one-shot duration 50 mS
-9L-
8L
Sequencer output one-shot duration 60 mS
-9M-
* Use Z2 computer command to store in memory prior to power off. CONTINUED ON NEXT PAGE…
Page 59 Downloaded from www.Manualslib.com manuals search engine
Page 64
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
30. Sequencer Controls Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
8M
Sequencer output one-shot duration 70 mS
-9N-
8N
Sequencer output one-shot duration 80 mS
-9O-
8O
Sequencer output one-shot duration 90 mS
-9P-
8P
Sequencer output one-shot duration 100 mS
-9Q-
8Q
Outputs sequencer *
8R
Does not output sequencer *
-9R- % -9S-
* Use Z2 computer command to store in memory prior to power off.
31. Motor Controls Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
S6
Motor always ON
-T7/ %
S5
Motor OFF until trigger
-T6-
Page 60 Downloaded from www.Manualslib.com manuals search engine
Page 65
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
Appendix D Dimensional Drawings
All dimensions in millimeters
Page 61 Downloaded from www.Manualslib.com manuals search engine
Page 66
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
Appendix E LPN5627 - Optical Performance (typical unit)
Depth of Field, PCS = .9
Resolution
6.0 mil
10.0 mil
13.3 mil
15.0 mil
20.0 mil 0
1
2
3
4
5
6
7
8
9
10
11
12
11
12
Distance from Unit (inches)
LPR5627 (Raster) - Optical Performance (typical unit)
Depth of Field, PCS = .9
Resolution
6.0 mil
10.0 mil
13.3 mil
15.0 mil
20.0 mil 0
1
2
3
4
5
6
7
8
9
10
Distance from Unit (inches)
Page 62 Downloaded from www.Manualslib.com manuals search engine
Page 67
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
Notes
Page 63 Downloaded from www.Manualslib.com manuals search engine