Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 7

User's Manual LPN5627, LPR5627 (Raster) Miniature High Speed Laser Fixed Position Scanner, pages 41 to 50

Pages 41 to 50 of 67

The original document is the PDF (492 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Opticon LPN-5627

Page 41

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

10. Fixing the Number of Digits Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

7V

Enable fixation (1 Length)

7W

Enable fixation (2 Lengths)

(H0)

Disable fixation

-I1- %

(H1)

Enable fixation (1 length)

-I2-

(H4)

Enable fixation (t lengths)

-I5-

H2

Disable 1 character Code 39 and Codabar (NW-7); Disable 2 characters 2 of 5

-I3- %

H3

Enable 1 character Code 39 and Codabar (NW-7); Enable 2 characters 2 of 5

-I!-

To avoid truncation errors, the scanner can be programmed to only decode bar codes of one specific length, i.e., containing a specific number of digits. It is also possible to program the scanner to only decode bar codes of either of two specific lengths. To fix one (1) length (or number of digits) of bar code: 1. Scan “START” to enter the programming mode 2. Scan “Enable fixation(H1)” bar code 3. Scan a sample bar code of the desired length 4. Repeat Step #3, re-scanning the sample bar code 5. Scan “STOP” to exit the programming mode

To fix two (2) different lengths of bar codes: 1. Scan “START” to enter the programming mode 2. Scan “Enable fixation(H4)” bar code 3. Scan a sample bar code of the desired length #1 4. Scan a sample bar code of the desired length #2 5. Scan “STOP” to exit the programming mode

NOTE: Fixation can also be programmed using computer commands through your RS232 by typing <ESC>7V<CR> followed by <+>2 digit length 1<CR>. 7W would be appropriate for length 2. Type<+>00<CR> to define either length as no fixed number. “Fixing the Number of Digits” can only be applied to Code 39, Codabar (NW-7), 2 or 5 and MSI/Plessey. WPC, Code 93, IATA and Code 128 are not affected.

Page 37 Downloaded from www.Manualslib.com manuals search engine

Page 42

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

11. Creating a Prefix and/or Suffix Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

1Y

Clear all Prefixes

-2Z- %

Z4

Display Prefix/Suffix value and length (expressed in hexidecimal format)

-[5-

The scanner can be programmed to transmit a prefix and/or suffix with the decoded data. A Prefix (or a Suffix) is composed of up to 4 characters. The following steps are used to establish a Prefix that will be transmitted with the bar code data: 1. Scan Start 2. Scan the bar code representing the symbology to which you wish to add a Prefix 3. Scan the character(s) that will comprise the Prefix. Up to four numeric, alpha or control character(s) may be used. 4. Scan “STOP” to exit the Programming Mode.

Example: To add the alpha character “A” as a Prefix and “B” as a Suffix to UPC-A bar code data: 1. 2. 3. 4. 5. 6.

Scan “START/END Programming Mode” Scan N1, representing a Prefix for UPC-A Scan 0A, representing the alpha character “A” Scan N6, representing a Suffix for UPC-A Scan 0B, representing the alpha character “B” Scan “START/END Programming Mode”

The same steps are used to establish a Suffix.

Page 38 Downloaded from www.Manualslib.com manuals search engine

Page 43

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

12. Setting Prefixes (Identifying the Symbology) Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

1Y

Clear all Prefixes

-2Z- %

N1

UPC-A

-O2-

M0

UPC-A +2 or +5

-N1-

N2

UPC-E

-O3-

M1

UPC-E +2 or +5

-N2-

N3

EAN-13

-O!-

M2

EAN –13 +2 or +5

-N3-

N4

EAN-8

-O5-

M3

EAN-8 +2 or +5

-N!-

M4

Code 39

-N5-

M5

Codabar (NW-7)

-N6-

M6

Industrial 2 of 5

-N7-

M7

Interleaved 2 of 5

-N8CONTINUED ON NEXT PAGE...

Page 39 Downloaded from www.Manualslib.com manuals search engine

Page 44

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

12. Setting Prefixes (Identifying the Symbology) (continued) Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

M8

Code 93

-N9-

M9

Code 128

-N:-

D8

IATA

-E9-

N0

MSI/Plessey

-O1-

Z4

Display Prefix/Suffix value and length (expressed in hexidecimal format)

-[5-

13. Setting Suffixes (Identifying the Symbology) Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

1Z

Clear all Suffixes

-2[-

N6

UPC-A

-O7-

O0

UPC-A +2 or +5

-P1-

N7

UPC-E

-O8-

O1

UPC-E +2 or +5

-P2-

N8

EAN-13

-O9COINTINUED ON NEXT PAGE...

Page 40 Downloaded from www.Manualslib.com manuals search engine

Page 45

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

13. Setting Suffixes (Identifying the Symbology) (continued) Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

O2

EAN–13 +2 or +5

-P3-

N9

EAN-8

-O:-

O3

EAN-8 +2 or +5

-P!-

O4

Code 39

-P5-

O5

Codabar (NW-7)

-P6-

O6

Industrial 2 of 5

-P7-

O7

Interleaved 2 of 5

-P8-

O8

Code 93

-P9-

O9

Code 128

-P:-

D9

IATA

-E:-

N5

MSI/Plessey

-O6-

Z4

Display Suffix value and length

-[5-

NOTE: The global default, also clears all suffixes.

Page 41 Downloaded from www.Manualslib.com manuals search engine

Page 46

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

14. Direct Input of Numeric Characters Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

Q0

0

-R1-

Q1

1

-R2-

Q2

2

-R3-

Q3

3

-R!-

Q4

4

-R5-

Q5

5

-R6-

Q6

6

-R7-

Q7

7

-R8-

Q8

8

-R9-

Q9

9

-R:-

Page 42 Downloaded from www.Manualslib.com manuals search engine

Page 47

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

15. Direct Input of Alpha Characters

-[8-

0N

N

-1O-

A

-1B-

0O

O

-1P-

0B

B

-1C-

0P

P

-1Q-

0C

C

-1D-

0Q

Q

-1R-

0D

D

-1E-

0R

R

-1S-

0E

E

-1F-

0S

S

-1T-

0F

F

-1G-

0T

T

-1U-

0G

G

-1H-

0U

U

-1V-

0H

H

-1I-

0V

V

-1W-

0I

I

-1J-

0W

W

-1X-

0J

J

-1K-

0X

X

-1Y-

0K

K

-1L-

0Y

Y

-1Z-

0L

L

-1M-

0Z

Z

-1[-

0M

M

-1N-

(Z7)

START/END Program Menu

(Z7)

START/END Program Menu

0A

-[8-

Page 43 Downloaded from www.Manualslib.com manuals search engine

Page 48

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

16. Direct Input of Control Characters Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

1A

STX

-2B-

1B

ETX

-2C-

1C

CR

-2D-

1D

LF

-2E-

17. Enable Number of Characters/Digits Transmitted This feature instructs the scanner to calculate and transmit a number indicating the total number of characters that are being transmitted to the host. This feature allows the host to verify that the correct amount of data was received. Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

3A

UPC-A

-!B-

3B

UPC-A +2 or +5

-!C-

3C

UPC-E

-!D-

3D

UPC-E +2 or +5

-!E-

3E

EAN-13

-!F-

3F

EAN-13 +2 or +5

-!GCONTINUED ON NEXT PAGE...

Page 44 Downloaded from www.Manualslib.com manuals search engine

Page 49

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

17. Enable Number of Characters/Digits Transmitted (continued)

(Z7)

START/END Programming Menu

-[8-

3G

EAN-8

-!H-

3H

EAN-8 +2 or +5

-!I-

3I

Code 39

-!J-

3J

Codabar (NW-7)

-!K-

3K

Industrial 2 of 5

-!L-

3L

Interleaved 2 of 5

-!M-

3M

Code 93

-!N-

3N

Code 128

-!O-

3O

MSI/Plessey

-!P-

3P

IATA

-!Q-

3Z

Transmit data length (all symbologies)

-![-

Page 45 Downloaded from www.Manualslib.com manuals search engine

Page 50

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

18. Disable Number of Characters/Digits Transmitted Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

2A

UPC-A

-3B-

2B

UPC-A +2 or +5

-3C-

2C

UPC-E

-3D-

2D

UPC-E +2 or +5

-3E-

2E

EAN-13

-3F-

2F

EAN-13 +2 or +5

-3G-

2G

EAN-8

-3H-

2H

EAN-8 +2 or +5

-3I-

2I

Code 39

-3J-

2J

Codabar (NW-7)

-3K-

2K

Industrial 2 of 5

-3L-

2L

Interleaved 2 of 5

-3M-

2M

Code 93

-3NCONTINUED ON NEXT PAGE…

Page 46 Downloaded from www.Manualslib.com manuals search engine