For the Opticon LPN-5627

Page 31

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner ♦ ♦

LPN5627 / LPR5627 Laser Fixed Mount

Good LED after decoding (green, 200 ms). RS232C (9600 baud, 8, 1, no parity, no handshaking).

Read Rate Mode (U8) - This mode resets all unit parameters to a predefined set of defaults for the purpose of checking the scanner read rate. When activated, the test result is sent via RS232C and indicates the ration of the number of successful read to the total number of attempts. The test result is reported in the following format: 700 d OK: 93.5% *CODE-39 TEST* Where:

The predefined defaults are the following:

♦

♦ ♦

♦ ♦

700d indicates the number of times the decoder ran while scanning at 700 scans per second (the number can be lower than 700 with poor quality barcodes). 93.5% indicates the percentage of good reads to total attempts. T The control character to be output is CR (0DE carriage return line fed), "ESC[3A" (cursor 3 line UP).

♦ ♦ ♦ ♦ ♦ ♦ ♦

Reads all barcodes by symbology. No fixed number of digits defined (32 digits max.). Normal scan, multiple scan. Trigger disabled. Small and large. Buzzer 3 KHz, volume max.) Buzzer after decoding (10 ms). Good LED after decoding (green 100 ms) RS232C (9600 bps, 8, 1, np, no handshaking).

Page 27 Downloaded from www.Manualslib.com manuals search engine

Page 32

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

2. Symbology Selection Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

A0

Enable all bar code symbologies

-B1-

A1

Only WPC (including Addon)

-B2-

A2

Only Code 39

-B3-

A3

Only Codabar (NW-7)

-B!-

A4

Only 2 of 5 (Industrial or Interleaved)

-B5-

A5

Only Code 93

-B6-

A6

Only Code 128

-B7-

A7

Only MSI/Plessey

-B8-

A8

Only IATA

-B9-

J1

Only UPC (A/E)

-K2-

J2

Only UPC (A/E)+2

-K3-

J3

Only UPC (A/E)+5

-K!-

J4

Only EAN

-K5-

J5

Only EAN +2

-K6CONTINUED ON NEXT PAGE…

Page 28 Downloaded from www.Manualslib.com manuals search engine

Page 33

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

2. Symbology Selection (continued) Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

J6

Only EAN +5

-K7-

J7

Only Industrial 2 of 5

-K8-

J8

Only Interleaved 2 of 5

-K9-

Z9

Remote Menu

-[:-

3. Add/Activate Specific Bar Code Symbologies Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

B1

Enable all WPC (including Addon)

B2

Enable Code 39

-C2- % -C3- %

B3

Enable Codabar (NW-7)

B4

Enable 2 of 5 (Industrial/Interleaved)

B5

Enable Code 93 (Factory Set)

-C6-

B6

Enable Code 128 (Factory Set)

-C7-

-C!- % -C5- %

CONTINUED ON NEXT PAGE…

Page 29 Downloaded from www.Manualslib.com manuals search engine

Page 34

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

3. Add/Activate Specific Bar Code Symbologies (continued) Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

B7

Enable MSI/Plessey

-C8-

B8

Enable IATA

-C9-

R1

Enable UPC (A/E)

-S2-

R2

Enable UPC (A/E) +2

-S3-

R3

Enable UPC (A/E) +5

-S!-

R4

Enable EAN (13/8)

-S5-

R5

Enable EAN (13/8) +2

-S6-

R6

Enable EAN (13/8) +5

-S7-

R7

Enable Industrial 2 of 5

-S8-

R8

Enable Interleaved 2 of 5

-S9-

Page 30 Downloaded from www.Manualslib.com manuals search engine

Page 35

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

4. Delete/Deactivate Specific Bar Code Symbologies Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

4A

Disable all WPC (including Addon)

-5B-

4B

Disable UPC (A/E)

-5C-

4C

Disable UPC (A/E) +2

-5D-

4D

Disable UPC (A/E) +5

-5E-

4E

Disable EAN (13/8)

-5F-

4F

Disable EAN (13/8) +2

-5G-

4G

Disable EAN (13/8) +5

-5H-

4H

Disable Code 39

-5I-

4I

Disable Codabar (NW-7)

-5J-

4J

Disable 2 of 5 (Industrial/Interleaved)

-5K-

4K

Disable Industrial 2 of 5

-5L-

4L

Disable Interleaved 2 of 5

-5M-

4M

Disable Code 93

-5NCONTINUED ON NEXT PAGE…

Page 31 Downloaded from www.Manualslib.com manuals search engine

Page 36

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

4. Delete/Deactivate Specific Bar Code Symbologies (continued) Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

4N

Disable Code 128

-5O-

4O

Disable MSI/Plessey

-5P-

4P

Disable IATA

-5Q-

4Z

Disable all symbologies

-5[-

Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

E2

UPC-A (13 Digits) Add leading zero; Enable check digit

-F3- %

E3

UPC-A (12 Digits) Do not add leading zero; Enable check digit

-F!-

E4

UPC-A (12 Digits) Add leading zero; Disable check digit

-F5-

E5

UPC-A (11 Digits) Do not add leading zero; Disable check digit

-F6-

E6

UPC-E (8 Digits) Add leading zero; Enable check digit

-F7-

E7

UPC-E (7 Digits) Do not add leading zero; Enable check digit

-F8-

E8

UPC-E (7 Digits) Add leading zero; Disable check digit

E9

UPC-A (6 Digits) Do not add leading zero; Disable check digit

5. Options for UPC

-F9- % -F:Page 32

Downloaded from www.Manualslib.com manuals search engine

Page 37

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

6. Options for Code 39 Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

7C

Enable 1 character (3 characters including start/stop characters)

-8D-

7D

Disable 1 character

C0

Disable check digit calculation

C1

Enable check digit calculation

C2

Transmit check digit

C3

Do not transmit check digit

-D!-

D0

Do not transmit start/stop characters (*……*)

-E1-

D1

Transmit start/stop characters (*……*)

-8E- % -D1- % -D2-D3- %

-E2- %

•

43 Data digits are available: 0 to 9, A to Z (caps only) plus . - $ / + % and space. If a check digit is present, it will appear as part of the data.

•

If the scanner is programmed to calculate the check digit, and the bar code is not printed with a check digit, the bar code will not read.

•

Another option available for Code 39 is to enable the reading of a single character bar code. See the section on Fixing the Digit for this option.

Page 33 Downloaded from www.Manualslib.com manuals search engine

Page 38

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

7. Options for Codabar (NW-7) Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

7K

Enable 1 character (3 characters including start/stop characters)

-8L-

7L

Disable 1 character

-8M- %

F0

Do not transmit start/stop characters

-G1-

F1

Transmit start/stop characters as ABCD/TN*E

-G2-

F2

Transmit start/stop characters as abcd/tn*e

-G3-

F3

Transmit start/stop characters as ABCD/ABCD

-G!-

F4

Transmit start/stop characters as abcd/abcd

F5

Transmit check digit

-G5- % -G6- %

F6

Do not transmit check digit

-G7-

F7

Do not calculate check digit

-G8- %

F8

Calculate check digit (Modulo 10)

-G9-

F9

Calculate check digit (Modulo 16) (AIM specifications)

-G:-

FB

Calculate check digit (Modulo 7)

-GCCONTINUED ON NEXT PAGE…

Page 34 Downloaded from www.Manualslib.com manuals search engine

Page 39

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

Codabar (NW-7) Format Start Character

1 to 42 data digits

Check digit

Stop Character

A.... a.... A.... a....

....T ....t ....A ....a

•

Codabar (NW-7) has four different start/stop character schemes as shown above. The check digit is optional and, if present, would be the last character.

•

If the scanner is programmed to calculate the check digit and the bar code is not printed with a check digit, the bar code will not be read.

8. Options for Interleaved 2 of 5 Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

G0

Do not calculate check digit

G1

Calculate check digit

-H2-

G2

Transmit Check digit

-H3- %

G3

Do not transmit check digit

-H!-

7M

Enable 2 characters

-8N-

7N

Disable 2 characters

-8O- %

-H1- %

2 of 5 Format (Standard and Interleaved) 1 to 44 data digits numeric only (0 to 9)

CD Check Digit

Opticon strongly recommends that the “Fixing the Number of Digits” featured on page 32 be employed whenever 2 of 5 bar codes are used.

Page 35 Downloaded from www.Manualslib.com manuals search engine

Page 40

Manual No. 25-ULPNR101-03; Feb, 2003 Scanner

LPN5627 / LPR5627 Laser Fixed Mount

9. Options for IATA Computer Command

Function /Description

Bar Code Command

(Z7)

START/END Programming Menu

-[8-

D2

Do not calculate check digit

D3

Calculate check digit (CPN + Form + Serial)

-E!-

D4

Calculate check digit (Form + Serial)

-E5-

D5

Calculate check digit (All data)

-E6-

D6

Transmit check digit

-E7-

D7

Do not transmit check digit

-E3- %

-E8- %

The IATA code is a variable length symbology with an optional check digit and non-printable start/stop characters. The following characters are supported: Digits 0 up to 9. The checksum is calculated as the modulo seven of the data string. IATA is an acronym for International Air Transport Association. String format

CPN

Meaning of Acronym

Coupon

Number of digits (15 total)

♦ ♦ ♦

1

AC Airline Code 3

FC Form Code 2

SN Serial Number 8

CD Check Digit 1

Enable check digit check Selection of the check digit calculation Disable transmission of the check digit

Check digit calculation: If the check digit calculation is required, then the appropriate calculation method must be selected.

Page 36 Downloaded from www.Manualslib.com manuals search engine