Page 21
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
Appendix A Programming the Scanner Two different methods can be used to program parameters to configure the scanner: a. Programming via Computer Commands b. Programming via special Bar Codes from a menu page Most parameters can be programmed using either of these two methods. However, there are certain parameters that are only programmable via the bar code menu.
a. Programming via Computer Commands Parameters can be programmed by sending software commands or keyboard strokes from the host computer to the scanner in the following format: <ESC> Computer Command <CR> Note:
Only upper case letters are recognized, e.g., “AB” not” ab” Each command normally consists of two characters Downloading of software commands cannot be “grouped” together. Each command must be preceded by <ESC> and followed by a <CR>
Parameters programmed by downloaded commands can be stored permanently by transmitting a “<ESC> Z2 <CR>” command. It is not necessary to send a “Z2” command after each parameter is changed. One Z2 command will save all changes Appendix B lists all of the Computer Commands. In Appendix C, Bar Code Programming Menus, the lefthand column in all menus contains the Computer Command associated with that bar code.
b. Programming via Bar Codes Use the following steps to program parameters via the bar code menus: 1. Scan the “Start/End” bar code. This instructs the scanner to enter the Programming Mode. While in this mode the scanner will beep intermittently. 2. Scan the bar code(s) associated with the desired parameter(s). The scanner will beep when the bar code is read. Note: because of the close proximity of bar codes on the page, it iis important to aim carefully to ensure that only the desired bar code is scanned. 3. Scan the “Start/End” bar code. This instructs the scanner to exit the Programming Mode.
All the parameters that were scanned are retained in memory and are stored permanently (even if the scanners is power down) or until they are changed again. When the scanner is in the Programming Mode, you can change more than one parameter at a time. However, this may become confusing. Until you be come proficient at programming you may prefer to Page 17 Downloaded from www.Manualslib.com manuals search engine
Page 22
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount change only a few parameters at one time. We recommend that you keep a record of the changes you have made to the scanner.
What if you make a mistake? Don’t worry. If you are programming the scanner but are unsure of which parameters have been changed, scan the Reset All Defaults bar code. This bar code returns the scanner to the default settings that were installed in the factory at the time the product was manufactured. Scanning this bar code erases any change you have made, including any changes that were made during previous programming. Reset All Defaults U1 Command (U1) This command will return all setting to the factory default setting that were installed in the factory We recommend that after you have reset all defaults you also set the commands for No Handshaking (P0), All Symbologies (A0), and Do Not Transmit Start/Stop Characters (D0) for Code 39.
Reset All Defaults
Computer Command
Function / Description
Bar Code Command
Z7
START/END Programming Mode
-[8-
U1
Reset All Defaults
-V2-
A0
Decodes all Symbologies
-B1-
P0
No Handshaking
-Q1-
D0
For Code 39: do not transmit start/stop characters *….*
-E1-
Z2
Save settings in memory
-[3-
Z7
START/END Programming Mode
-[8-
Appendix C contains all the Bar Code Programming menus and commands
Page 18 Downloaded from www.Manualslib.com manuals search engine
Page 23
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
Appendix B Computer Programming Commands All commands must be preceded by an 'ESC' character and be followed by a 'Carriage Return' character. Shaded areas indicate factory default settings.
Enable
Disable
Global Defaults
J3
R3
4D
UPC (A/E)+5
U1
Enable Factory Default Settings
J4
R4
4E
EAN
1Y
Clear all prefixes
J5
R5
4F
EAN+2
1Z
Clear all suffixes
J6
R6
4G
EAN+5
P9
Transmit Barcode Pattern Data
4Z
Disable all Symbologies
U8
Read Rate Test Mode
Z1
Clear all values set by command
Z2
Save all values set by command
Z3
Display software settings & version no.
Z4
Display prefix/suffix
Only
Add
Rmv
A0
Enable
Disable
E2
UPC-A (13 Digits) Leading zero & CD
E3
UPC-A (12 Digits) No leading 0 & CD
E4
UPC-A (12 Digits) Leading zero & No CD
E5
UPC-A (11 Digits) No leading 0 & no CD
E6
UPC-E (8 Digits) Leading 0 & CD
E7
UPC-E (7 Digits) No leading zero & CD
E8
UPC-E (7 Digits) Leading zero; no CD
E9
UPC-E (6 Digits) No leading 0 & no CD
Symbology Selection Enable all symbologies
Options for UPC
A1
B1
4A
WPC (including add-ons)
A2
B2
4H
Code 39
A3
B3
4I
Codabar (NW-7)
A4
B4
4J
2 or 5 Industrial or Interleaved
J7
R7
4K
2 or 5 Industrial
Enable
Disable
Options for Code 39
J8
R8
4L
2 or 5 Interleaved
7C
7D
Enable 1 character read
A5
B5
4M
Code 93
C1
C0
Enable Check Digit calculation
A6
B6
4N
Code 128
C2
C3*
Transmit Check Digit
A7
B7
4O
MSI/Plessey
D1
D0
A8
B8
4P
IATA
Transmit start/stop characters (*…..*)
J1
R1
4B
UPC (A/E)
J2
R2
4C
UPC (A/E)+2
•
Only disable if C1 enabled, otherwise truncate last digit.
Page 19 Downloaded from www.Manualslib.com manuals search engine
Page 24
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
Enable
Disable
7K
7L
Options for Codabar (NW-7) Enable 1 character read
LPN5627 / LPR5627 Laser Fixed Mount
N1
N6
UPC-A
M0
O0
UPC-A +2 or +5
N2
N7
UPC-E
M1
O1
UPC-E +2 or +5
N3
N8
EAN13
M2
O2
EAN-13 +2 or +5
F0
Do not transmit start/stop characters
F1
Transmit start/stop as ABCD/TN*E
F2
Transmit start/stop as abcd/tn*e
N4
N9
EAN-8
F3
Transmit start/stop as ABCD/ABCD
M3
O3
EAN-8 +2or +5
F4
Transmit start/stop as abcd/abcd
M4
O4
Code 39
Transmit check digit
M5
O5
Codabar (NW-7)
F7
Do not calculate check digit
M6
O6
Industrial 2 of 5
F8
Calculate check digit (modulo 10)
M7
O7
Interleaved 2 of 5
F9
Calculate CD (modulo 16) AIM spec.
M8
O8
Code 93
M9
O9
Code 128
FB
Calculate check digit (modulo 7)
D8
D9
IATA
N0
N5
MSI/Plessey
F5
F6
Enable
Disable
G1
G0
Calculate check digit
G2
G3
Transmit check digit
7M
7N
Enable 2 characters
Enable
Disable
Options for IATA
Options for Interleaved 2 of 5
Prefix/Suffix of Numeric Characters Q0
0 thru thru
Q9
9 Prefix/Suffix of Alpha Characters
D2
Do not calculate check digit
D3
Calculate CD (CPN + Form + Serial)
0A
A thru thru
D4
Calculate CD (Form + Serial)
0Z
Z
D5
Calculate check digit (all data)
D6
D7
Transmit check digit
Prefix
Suffix
Creating a Prefix and/or Suffix
1Y
1Z
Clear all
Z4
Z4
Display Prefix/suffix values & length
Prefix/Suffix of Control Characters 1A
STX
1B
ETX
1C
Carriage Return (Default Suffix Character)
1D
Line Feed
Select Symbology for Prefix/Suffix
Page 20 Downloaded from www.Manualslib.com manuals search engine
Page 25
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
Communications Parameters
LPN5627 / LPR5627 Laser Fixed Mount
P5
No ACK/NAK
Enable
Disable
Enable character length transmission
K1
300 baud
K2
600 baud
3A
2A
UPC-A
K3
1,200 baud
3B
2B
UPC-A +2 or +5
K4
2,400 baud
3C
2C
UPC-E
K5
4,800 baud
3D
2D
UPC-E +2 or +5
K6
9,600 baud
3E
2E
EAN13
K7
19,200 baud
3F
2F
EAN-13 +2 or +5
K8
38,400 baud
3G
2G
EAN-8
L0
7 Data Bits
3H
2H
EAN-8 +2or +5
L1
8 Data Bits
3I
2I
Code 39
L2
Parity = None
3J
2J
Codabar (NW-7)
L3
Parity = Even
3K
2K
Industrial 2 of 5
L4
Parity = Odd
3L
2L
Interleaved 2 of 5
L5
1 Stop bit
3M
2M
Code 93
L6
2 Stop bits
3N
2N
Code 128
3O
2O
MSI/Plessey
Handshaking
3P
2P
IATA
I0
Unlimited wait for CTS from terminal
3Z
2Z
Transmit data length of all symbologies
I1
100 mS wait for CTS from terminal
I2
200 ms wait for CTS from terminal
Enable
Disable
I3
400 mS wait for CTS from terminal
I4
Unlimited ACK/NAK Timeout delay
I5
100 mS ACK/NAK Timeout delay
I6
500 mS ACK/NAK Timeout delay
I7
1000 mS ACK/NAK Timeout delay
P0
No Handshaking
P1
Busy/Ready
P2
Modem
T0
Volume = Maximum
P3
ACK/NAK
T1
Volume = Upper mid-range
P4
ACK/NAK No buzzer on timeout
T2
Volume = Lower mid-range
Fixed Number of Digits
7V
Enable fixation (1st Length)
7W
Enable fixation (2nd Length)
H0
Disable fixation
H3
H2
Enable 1 digit Code 39 and Codabar (NW-7) and enable 2 digit 2 of 5
Buzzer Operation
Page 21 Downloaded from www.Manualslib.com manuals search engine
Page 26
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner T3
Volume = Minimum
V5
Ring buzzer once at 3kHz for 200 mS
V6
Ring buzzer at 3kHz & 2kHz for 200 mS
V7
Ring buzzer at 2kHz & 3kHz for 200 mS
W0
LPN5627 / LPR5627 Laser Fixed Mount
Scanner Timeout (Trigger Enabled Mode) Y0
Laser remains ON as long as trigger is pulled (hardware trigger only)
Disable Buzzer
Y1
1 second after triggering
W1
Enable buzzer at 3kHz
Y2
2 second after triggering
W2
Enable buzzer at 3kHz with 2.5kHz interval
Y3
3 second after triggering
W3
Enable buzzer at 2kHz with 3kHz interval
Y4
4 second after triggering
W4
Buzzer duration 0.10 sec
Y5
6 second after triggering
W5
Buzzer duration 0.20 sec
Y6
8 second after triggering
W6
Buzzer duration 0.40 sec
Y7
10 second after triggering
W7
Buzzer duration 0.05 sec
W8
Buzzer duration 0.01 sec
Redundant Decoding X0
Read bar code once
X1
Read bar code twice before transmitting
Positive & Negative Bar Codes
X2
Read bar code three times before transmitting
V4
Positive bar codes only
X3
Read bar code four times before transmitting
V2
Both positive and negative bar codes
7R
Read bar code five times before transmitting
7S
Read bar code six times before transmitting
Setting the Trigger Function S7
Disable the trigger function (Laser On)
S8
Enable the trigger function (Laser OFF until the trigger is activated )
Z
Activate the trigger; turns the laser ON
S0
Xmit Error (Trigger Enabled Mode only) 5E
Do not Xmit error code
5F
Xmit “BR” <CR> for bad read or no read
5G
Xmit <STX> ”>” <ETX> for bad read; <STX> “?” <ETX> for no read
Selecting the Read Mode
5H
Single Read Mode (Trigger must be Enabled, S8)
Xmit “>” <CR> for bad read,”?” <CR> or no read
5I
Transmit “<CAN>” <CR> for bad read or no read
5J
Xmit “<CAN>”<ETX> for bad read or no read
S1
Multiple Read Mode
S2
Continuous Read Mode
7H
Does not allow first bar distortion
7I
Allow first bar distortion
7O
Normal scan
Print Quality Adjustment X4
For lower density, poor print (low gain)
X5
For high density, good print quality bar code without voids (high gain)
X6
Xmit data from Low or High gain
Page 22 Downloaded from www.Manualslib.com manuals search engine
Page 27
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner X7
LPN5627 / LPR5627 Laser Fixed Mount
Xmit data from Low and High gain Trigger Input, OK & NG Output Controls Good Read LED Operation
8A
Trigger Input (positive logic) High active
8B
Trigger Input (negative logic) Low active
8C
Output synchronous transmission (negative – true logic)
8D
Output synchronous transmission (positive – true logic)
8E
Output one-shot transmission (negative – true logic)
T4
Disable good read LED (GRL)
T8
GRL ON for 0.10 seconds after decode
T5
GRL ON for 0.20 seconds after decode
T6
GRL ON for 0.40 seconds after decode
T7
GRL ON for 0.80 seconds after decode
V0
LED ON Red for 0.40 seconds
8F
Output one-shot Xmit (positive – true logic)
V1
LED ON Red for 0.80 seconds
8G
Output one-shot duration 10 mS
V8
LED ON Green for .40 seconds
8H
Output one-shot duration 20 mS
V9
LED ON Green for .80 seconds
8I
Output one-shot duration 30 mS
8J
Output one-shot duration 40 mS
8K
Output one-shot duration 50 mS
8L
Output one-shot duration 60 mS
8M
Output one-shot duration 70 mS
8N
Output one-shot duration 80 mS
8O
Output one-shot duration 90 mS
8P
Output one-shot duration 100 mS
8Q
Enable outputs
8R
Disable outputs
Motor Control S6
Motor always ON
S5
Motor OFF until trigger
Page 23 Downloaded from www.Manualslib.com manuals search engine
Page 28
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
Appendix C: Bar Code Programming Menus & Commands Index 1. Global Default & Scanner Configurations....................................... 25 2. Symbology Selection ................................................................... 28 3. Add/Activate Specific Bar Code Symbologies ................................. 29 4. Delete/Deactivate Specific Bar Code Symbologies.......................... 31 5. Options for UPC.......................................................................... 32 6. Options for Code 39.................................................................... 33 7. Options for Codabar (NW-7) ........................................................ 34 8. Options for 2 of 5 ....................................................................... 35 9. Options for IATA ........................................................................ 36 10. Fixing the Number of Digits ........................................................ 37 11. Creating a Prefix and/or Suffix .................................................... 38 12. Setting Prefixes (Identifying the Symbology) ................................ 39 13. Setting Suffixes (Identifying the Symbology) ................................ 40 14. Direct Input of Numeric Characters ............................................. 42 15. Direct Input of Alpha Characters ................................................. 43 16. Direct Input of Control Characters ............................................... 44 17. Enable Number of Characters/Digits Transmitted.......................... 44 18. Disable Number of Characters/Digits Transmitted ......................... 46 19. Communication Parameters ........................................................ 47 20. Handshaking ............................................................................. 49 21. Buzzer Operation ....................................................................... 50 22. Positive & Negative Bar Codes .................................................... 52 23. Setting the Trigger Function ....................................................... 52 24. Selecting the Read Mode ............................................................ 53 25. Scanner Timeout (Trigger Enabled Mode only) ............................. 55 26. Redundant Decoding.................................................................. 56 27. Transmitting Error Indications (Trigger Enabled only) ................... 57 28. Print Quality Adjustments ........................................................... 57 29 Good Read Indicator Operation .................................................. 586 30. Sequencer Controls .................................................................... 59 31. Motor Control ............................................................................ 60
Page 24 Downloaded from www.Manualslib.com manuals search engine
Page 29
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
1. Global Default & Scanner Configurations Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
U1
Return all parameters to Default settings
1Y
Clear all prefixes
-2Z-
1Z
Clear all suffixes
-2[-
P6
Disable Graph Mode
-Q7-
U0
Scanner Test Mode
-V1-
U8
Read Rate Mode
-V9-
U9
Graph Mode (TBD)
-V:-
-V2- %
CONTINUED ON NEXT PAGE…
Page 25 Downloaded from www.Manualslib.com manuals search engine
Page 30
Manual No. 25-ULPNR101-03; Feb, 2003 Scanner
LPN5627 / LPR5627 Laser Fixed Mount
1. Global Default & Scanner Configurations (continued) Computer Command
Function /Description
Bar Code Command
(Z7)
START/END Programming Menu
-[8-
Z1
Reset all values set by command
-[2-
Z2
Save all values set by command (not lost upon power off)
-[3-
Z3
Display software settings and version number
-[!-
Z4
Display prefix/suffix value length (expressed in hexadecimal format)
-[5-
Note: Where computer commands appear in parenthesis, bar code commands must be used to program the scanner.
%) symbol throughout the menus to
Note: Scanner default settings are indicated by a pointing hand ( follow.
* Use Z2 (Save all values set by command) after computer command to store settings in memory prior to power off. Scanner Test Mode (U0) - This mode resets all unit parameters to a predefined set of defaults for the purpose of putting the scanner into a test mode which reads barcodes continuously. The predefined defaults are the following: ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Reads all barcodes by symbology No fixed number of digits defined (32 digits minimum). Normal scan, continuous scan. Large only. No verification, no "Bad Read (BR)". Buzzer 3KHz, volume maximum. Buzzer after decoding (10 ms). Good LED after decoding (green, 100 ms). RS232C (9600 baud, 8, 1, no parity, no handshaking).
Straight Across Scan Mode (U3) - This mode resets all unit parameters to predefined defaults for the purpose of allowing straight across scanning of up to 3 labels. The predefined defaults are the following: ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Reads all barcodes by symbology. No fixed number of digits defined (32 digits max.) Normal scan, multiple scan. Trigger disable. Small and large. No verification, no "Bad Read (BR)". Buzzer 3KHz and 2KHz, volume max. Buzzer after decoding (200 ms). Page 26
Downloaded from www.Manualslib.com manuals search engine