Summary

What is in it

Microscan user manual for the MS-Connect 210 connectivity box, a wiring box that connects a Microscan bar code reader to a host, with optional alphanumeric display and Ethernet. It lists the hardware and cables for stand-alone, multidrop and daisy chain setups, then covers configuring the display, connecting 10-28V and 5V readers, output settings, ESP software, Ethernet TCP/IP and EtherNet/IP setup with RSLogix and EIPScan examples, and specifications, data flow and DIN rail mounting.

Its parts

  1. Setting Up the Device
  2. Using Ethernet

From the manual

Key facts from this manual

Each line names its page in the PDF.

The user manual (P/N 84-210210 RevA, 2014) for the Microscan MS-Connect 210, a connectivity box that links Microscan readers to a host over RS-232, RS-422/485 or Ethernet. It covers the hardware lists, display and output switch settings, connecting 10-28 V and 5 V readers, and Ethernet and EtherNet/IP setup. The appendices give specifications, I/O wiring examples and DIN rail mounting.

Read for this summary: pages 1 to 6, 8 to 14, 21, 26, 38 to 39 and 52 to 62 of 65.

Device
Connectivity box that links Microscan readers to a host by RS-232, RS-422 or Ethernet p. 9, 53
Versions
FIS-0210-0001G with display; FIS-0210-0002G without display; FIS-0210-0003G with Ethernet and display p. 54
Compatible readers
10-28 V: MS-9, QX-830, QX-870, MS-890; 5 V through the IC-332 adapter: MS-1, MS-2, MS-3, MS-4, Quadrus MINI, Quadrus MINI 3, Quadrus MINI Velocity; also an MS-Q on terminal block J15 p. 12, 13, 14
Power
10-28VDC, 200mV p-p max. ripple; at 24VDC typical: box 32 mA, with display 90 mA, with Ethernet 62 mA, with both 120 mA p. 53
Ethernet
10/100M, TCP/IP, UDP and EtherNet/IP; one EtherNet/IP I/O connection and two TCP connections; BOOTP; TFTP firmware upload p. 38, 61
Connectors
Reader: M23 19-pin circular socket; Ethernet: 8-pin M12 Micro-Change; trigger: 4-pin Micro-Change socket; power: 3-pin Micro-Change plug p. 53
Discrete I/O
Trigger, New Master and Input 1 rated 5 to 28V (6.5mA at 24VDC); outputs 1, 2, 3 optoisolated pass-through, 1-28V, under 100mA, limited by the user p. 53
Display
2x20 alphanumeric characters, on FIS-0210-0001G and FIS-0210-0003G p. 4, 53
Parts
Power supply (10-28V) 97-100004-15; IC-332 power adapter FIS-0001-0035G; object detector 99-000017-02; host cable 61-000105-01; MS-Q reader cable 61-000066-02; internal Ethernet cable 61-000128-01 p. 9
DIN rail kit
P/N 98-000093-01 p. 62
Relay modules
Up to three Pluggable Series 70 relay modules (K1 to K3), in 120VAC, 240VAC and 24VDC versions p. 9, 55
Dimensions
7.3 in. (184 mm) long, 6.3 in. (160 mm) wide, 2.8 in. (71 mm) high; 1.6 lb. (726 g); mounting holes 6.6 x 2.5 in. (168 x 63.5 mm) p. 53
Environment
Operating 0 to 50°C (32 to 122°F); storage -30 to 70°C (-22 to 158°F); humidity up to 90% non-condensing; IP65 enclosure p. 53
Power protection
Reverse-voltage protection up to 30V; the Power LED lights red when polarity is wrong and green when it is right p. 26

What this manual walks you through

  • Hardware for stand-alone, multidrop and daisy chain setups p. 9, 10
  • Setting the display dip switches at SW3 to match the reader p. 11
  • Connecting a 10-28 volt reader p. 12
  • Connecting a 5 volt reader through the IC-332 power adapter p. 13
  • Wiring an MS-Q imager to terminal block J15 p. 14
  • Setting output polarity and beeper switches at SW5 p. 21
  • Configuring the Ethernet port with BOOTP, ESP, Telnet or DeviceInstaller p. 38, 39
  • Wiring optoisolated outputs and inputs p. 57, 58
  • How data flows between the reader, handheld, host, display and Ethernet ports p. 59
  • Mounting on a DIN rail p. 62

Good to know

  • The dip switches at SW4 are for factory use only and should not be moved. p. 11
  • Power must be cycled each time the display baud rate dip switches are changed. p. 11
  • Reversing the IC-332 adapter when connecting a 5 volt reader may seriously damage the interface. p. 13
  • The J1 power input terminal is always powered, whatever the power switch position. p. 26
  • No more than 100mA may pass through an output optoisolator. p. 57

Questions this manual answers

Which Microscan readers work with the MS-Connect 210?

The manual names the MS-9, QX-830, QX-870 and MS-890 as 10-28 volt readers, and the MS-1 to MS-4, Quadrus MINI, MINI 3 and MINI Velocity as 5 volt readers used with the IC-332 adapter. p. 12, 13

Why is the MS-Connect 210 power LED red?

The power connection polarity is reversed; the box then gets no power, and its reverse-voltage protection guards it up to 30V. p. 26

How does the MS-Connect 210 get its IP address?

At power-on it asks a BOOTP server for one, and falls back to a default IP address if none responds. p. 39

Which MS-Connect 210 version has the display?

FIS-0210-0001G (display) and FIS-0210-0003G (Ethernet and display); FIS-0210-0002G has none. p. 54

What DIN rail kit fits the MS-Connect 210?

The DIN Rail Mounting Kit, P/N 98-000093-01, with two adapter mounts, two DIN rail adapters and screws. p. 62

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. MS-Connect 210 User Manual1
    1. About the MS-Connect 2104
    2. About This Manual4
    3. Highlighting4
    4. Product Labels5
    5. Statement of Agency Compliance6
    6. Statement of RoHS Compliance7
    7. 1 Setting Up the Device8
    8. 2 Using Ethernet30
    9. Appendices52

From the PDF’s own bookmarks.

The whole text · 7 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 6561-65

The file

Revision and size

RevisionP/N 84-210210 RevA
PublisherMicroscan Systems, Inc.
Pages65
PDF2.4 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 65

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 65
Page 2
Page 2of 65
Page 3
Page 3of 65