Manual · Microscan
MS-Connect 210 User Manual
Manual65 pagesPDF 2.4 MB
User manual for the Microscan MS-Connect 210 connectivity box that links Microscan readers to a host by serial, Ethernet TCP/IP or EtherNet/IP.
Covers · 1 model
The models it covers
Summary
What is in it
Microscan user manual for the MS-Connect 210 connectivity box, a wiring box that connects a Microscan bar code reader to a host, with optional alphanumeric display and Ethernet. It lists the hardware and cables for stand-alone, multidrop and daisy chain setups, then covers configuring the display, connecting 10-28V and 5V readers, output settings, ESP software, Ethernet TCP/IP and EtherNet/IP setup with RSLogix and EIPScan examples, and specifications, data flow and DIN rail mounting.
Its parts
- Setting Up the Device
- Using Ethernet
From the manual
Key facts from this manual
Each line names its page in the PDF.
The user manual (P/N 84-210210 RevA, 2014) for the Microscan MS-Connect 210, a connectivity box that links Microscan readers to a host over RS-232, RS-422/485 or Ethernet. It covers the hardware lists, display and output switch settings, connecting 10-28 V and 5 V readers, and Ethernet and EtherNet/IP setup. The appendices give specifications, I/O wiring examples and DIN rail mounting.
- Device
- Connectivity box that links Microscan readers to a host by RS-232, RS-422 or Ethernet p. 9, 53
- Versions
- FIS-0210-0001G with display; FIS-0210-0002G without display; FIS-0210-0003G with Ethernet and display p. 54
- Compatible readers
- 10-28 V: MS-9, QX-830, QX-870, MS-890; 5 V through the IC-332 adapter: MS-1, MS-2, MS-3, MS-4, Quadrus MINI, Quadrus MINI 3, Quadrus MINI Velocity; also an MS-Q on terminal block J15 p. 12, 13, 14
- Power
- 10-28VDC, 200mV p-p max. ripple; at 24VDC typical: box 32 mA, with display 90 mA, with Ethernet 62 mA, with both 120 mA p. 53
- Ethernet
- 10/100M, TCP/IP, UDP and EtherNet/IP; one EtherNet/IP I/O connection and two TCP connections; BOOTP; TFTP firmware upload p. 38, 61
- Connectors
- Reader: M23 19-pin circular socket; Ethernet: 8-pin M12 Micro-Change; trigger: 4-pin Micro-Change socket; power: 3-pin Micro-Change plug p. 53
- Discrete I/O
- Trigger, New Master and Input 1 rated 5 to 28V (6.5mA at 24VDC); outputs 1, 2, 3 optoisolated pass-through, 1-28V, under 100mA, limited by the user p. 53
- Display
- 2x20 alphanumeric characters, on FIS-0210-0001G and FIS-0210-0003G p. 4, 53
- Parts
- Power supply (10-28V) 97-100004-15; IC-332 power adapter FIS-0001-0035G; object detector 99-000017-02; host cable 61-000105-01; MS-Q reader cable 61-000066-02; internal Ethernet cable 61-000128-01 p. 9
- DIN rail kit
- P/N 98-000093-01 p. 62
- Relay modules
- Up to three Pluggable Series 70 relay modules (K1 to K3), in 120VAC, 240VAC and 24VDC versions p. 9, 55
- Dimensions
- 7.3 in. (184 mm) long, 6.3 in. (160 mm) wide, 2.8 in. (71 mm) high; 1.6 lb. (726 g); mounting holes 6.6 x 2.5 in. (168 x 63.5 mm) p. 53
- Environment
- Operating 0 to 50°C (32 to 122°F); storage -30 to 70°C (-22 to 158°F); humidity up to 90% non-condensing; IP65 enclosure p. 53
- Power protection
- Reverse-voltage protection up to 30V; the Power LED lights red when polarity is wrong and green when it is right p. 26
What this manual walks you through
- Hardware for stand-alone, multidrop and daisy chain setups p. 9, 10
- Setting the display dip switches at SW3 to match the reader p. 11
- Connecting a 10-28 volt reader p. 12
- Connecting a 5 volt reader through the IC-332 power adapter p. 13
- Wiring an MS-Q imager to terminal block J15 p. 14
- Setting output polarity and beeper switches at SW5 p. 21
- Configuring the Ethernet port with BOOTP, ESP, Telnet or DeviceInstaller p. 38, 39
- Wiring optoisolated outputs and inputs p. 57, 58
- How data flows between the reader, handheld, host, display and Ethernet ports p. 59
- Mounting on a DIN rail p. 62
Good to know
- The dip switches at SW4 are for factory use only and should not be moved. p. 11
- Power must be cycled each time the display baud rate dip switches are changed. p. 11
- Reversing the IC-332 adapter when connecting a 5 volt reader may seriously damage the interface. p. 13
- The J1 power input terminal is always powered, whatever the power switch position. p. 26
- No more than 100mA may pass through an output optoisolator. p. 57
Questions this manual answers
Which Microscan readers work with the MS-Connect 210?
The manual names the MS-9, QX-830, QX-870 and MS-890 as 10-28 volt readers, and the MS-1 to MS-4, Quadrus MINI, MINI 3 and MINI Velocity as 5 volt readers used with the IC-332 adapter. p. 12, 13
Why is the MS-Connect 210 power LED red?
The power connection polarity is reversed; the box then gets no power, and its reverse-voltage protection guards it up to 30V. p. 26
How does the MS-Connect 210 get its IP address?
At power-on it asks a BOOTP server for one, and falls back to a default IP address if none responds. p. 39
Which MS-Connect 210 version has the display?
FIS-0210-0001G (display) and FIS-0210-0003G (Ethernet and display); FIS-0210-0002G has none. p. 54
What DIN rail kit fits the MS-Connect 210?
The DIN Rail Mounting Kit, P/N 98-000093-01, with two adapter mounts, two DIN rail adapters and screws. p. 62
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 7 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file