Page 61

Interface Standards

Appendix E, Interface Standards RS-232 RS-232 defines an interface between two devices such as, for example, the wiring box and a host computer. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (15.24 m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.

RS-422 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4,000 feet (1,219m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used.

RS-485 RS-485, like RS-422, can transmit up to 4,000 feet (1,219 m) using differential voltages. Unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in Multidrop configuration.

Ethernet Ethernet is supported for 10/100M, TCP/IP, UDP, and EtherNet/IP. A 6-byte address is used, which is divided into a 3-byte vendor ID and a 3-byte vendor-defined field. Ethernet manufacturers are assigned a unique vendor ID, and are then responsible for insuring that all of their devices have unique addresses in the last 3 bytes.

A-10

MS-Connect 210 User’s Manual

Page 62

Appendices

Appendix F, DIN Rail Mounting The MS-Connect 210 can be mounted on a wall or other vertical surface using Microscan’s DIN Rail Mounting Kit (P/N 98-000093-01). DIN Rail Mounting Kit Includes: Item 1 2 3 4

Qty. 2 2 4 4

Description Mount, Adapter, DIN Rail, MS-Connect 210 Adapter, DIN Rail Screw, 6-32 x 3/8”, Thread Cutting, FH, PHIL, SS Screw, 10-32 x 9/16”, PH, PHIL, SS

Part Number 10-000247-01 12-000298-01 12-000303-01 12-000302-01

3 4X

1 2X

2 2X

1. Attach the DIN Rail Adapter Mount (1) to the DIN Rail Adapter (2) using the two screws provided (3). 2. Repeat Step 1 with the other DIN Rail Adapter Mount and DIN Rail Adapter.

4 DIN Rail 3. Attach the two DIN Rail Adapter Mounts (1) to the underside of the MS-Connect 210 using the four screws provided (4), as shown in the illustration at right. 4. Mount the MS-Connect 210 on an available DIN Rail using the two DIN Rail Adapters (2).

MS-Connect 210 User’s Manual

MS-Connect 210

A-11

Page 63

Glossary of Terms

Appendix G, Glossary of Terms Aux RS-232 - The connection between a reader’s auxiliary port and a host. The MS-Connect 210 passes the RS-232 signal through, creating a condition in which the host’s RX/TX is connected directly to the reader. Baud Rate - The number of discrete signal events per second. Bits per second. Connector - Physical device (plug or socket) on a device or cable to provide in/out connectivity for various circuits and pins. Data Bits - The number of bits used to represent one character of data output. Decode - A Good Read. The successful capture and output of the information encoded in a symbol. Discrete I/O - Inputs and outputs characterized by discrete signal transitions from one voltage level to another so that digital switching can occur. Firmware - Software hard-coded in non-volatile memory. Good Read - A decode. The successful capture and output of the information encoded in a symbol. Host - A computer, PLC (Programmable Logic Controller), or other device that is used to execute commands and to process data and discrete signals. Host RS-232 - Enables a reader to communicate with a host although they are not directly connected. The reader is routed through the MS-Connect 210, and then to the host. Host RS-422 - The RS-422 connection between the MS-Connect 210 and the host. The MS-Connect 210 passes RS-422 from the reader to the host. Input - A channel or communications line. The decoded data or discrete signal that is received by a device. LED (Light-Emitting Diode) - Often used as a performance indicator, as on the exterior of the MS-Connect 210. Master Symbol - A symbol whose data is stored in a reader and compared to other symbols in an application as they are decoded. Useful in applications that require sortation and routing. Matchcode - A method of comparing current decoded symbol data against stored master symbol data. Useful in applications that require sortation and routing. Micro-Change - A threaded, sealed connector that provides secure cabling in industrial and automation environments. New Master - A condition in which a reader decodes and stores a new master symbol in an application using matchcode. No Read - A condition in which a reader fails to decode a candidate symbol. Normally Closed - A discrete output state that is only active when open. Normally Open - A discrete output state that is only active when closed.

A-12

MS-Connect 210 User’s Manual

Page 64

Appendices Opto-isolation - The transfer of signals between elements of a circuit (typically a transmitter and receiver) while keeping the elements electrically isolated. An example of opto-isolation is the relationship of an LED and a light sensor, separated from each other so that light can travel across a barrier but electrical current cannot. Output - A channel or communications line. The data or discrete signals that are transmitted or displayed by a device. Parity - An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1s in the data field is even or odd. Port - Logic circuit for receiving and transmitting data. (One or more ports may be included within a single connector.) Protocol - The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Read Cycle - A pre-defined period of time during which a reader will attempt to capture symbol data. RoHS (Reduction of Hazardous Substances) - A directive that restricts the use of lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB), and polybrominated diphenyl ether (PBDE) in the manufacture of certain types of electronic and electrical equipment. Signal - A transmission of analog or digital information, electrical current, voltage, or another specific quantity, that can be varied in such a way that it conveys information from one point to another. Symbology - A symbol type, such as Code 39 or Code 128, with special rules to define the widths and positions of bars (or 2D modules) and spaces to represent specific numeric or alphanumeric information. Terminal Block - An insulated block on a printed circuit board (PCB) that secures two or more wires together using a clamping device (usually screws or spring clips). Topology - The arrangement of a network, including communication nodes and connection lines. Trigger - A signal, transition, or character string that initiates a read cycle. UART (Universal Asynchronous Receiver/Transmitter) - A hardware device that converts bytes of data to and from bit streams represented as binary electrical impulses. Typically used with other communication standards, such as RS-232. VFD (Vacuum Fluourescent Display) - A very bright type of display (brighter than a liquid crystal display) often used on consumer electronics. The MS-Connect 210’s display is a VFD. Watchdog - A hardware timing device that restores the normal operation of a computer system (the display driver, in the case of the MS-Connect 210) if it stops functioning properly. WEEE (Waste Electrical and Electronic Equipment) - A directive that requires manufacturers of electrical and electronic equipment to take responsibility for the disposal of that equipment.

MS-Connect 210 User’s Manual

A-13

Page 65

Glossary of Terms

A-14

MS-Connect 210 User’s Manual