Page 51

TFTP Services

TFTP Services The Ethernet Port contains an embedded TFTP server that can be used to update the Ethernet Port firmware. The TFTP server only supports standard TFTP, not Extended TFTP. Free TFTP client software is available at http://www.weird-solutions.com/. When the server requests transmission of a packet, the TFTP client transmits the next packet’s data using the block number of the packet requested for re-transmission. Therefore, the server accepts it as the re-transmitted data, since the block numbers match. Re-transmission attempts occur only when using the Ethernet Port on a half-duplex hub with other network traffic present. The connection is extremely reliable over a full-duplex switch.

Firmware Upload Use a TFTP client to upload firmware. The firmware file must be a valid DSTniSPB (Special Program Binary) file with the “.spb” extension. Currently, any file name is accepted. The file’s first TFTP packet contains the SPB header and checksum information, which is validated before any data is written to flash. Note that due to RAM limitation in the Ethernet Port, the firmware file must be written to flash as the TFTP packets are received, one by one. Therefore, it is important to allow a firmware file enough time to upload completely before resetting the target Ethernet Port of closing the TFTP client. Once the header is validated and the upload begins, the old firmware is already being overwritten. Canceling the transfer before completion will result in corrupt firmware that will not load after the Ethernet Port is reset. If an error occurs during the transfer, DO NOT reset the Ethernet Port. Remedy the problem described in the TFTP error message and then attempt the upload again. A subsequent version of firmware will contain the capability for recovery from a corrupt state via an Ethernet boot. The current version supports recovery by loading firmware over the serial port.

2-22

MS-Connect 210 User’s Manual

Page 52

Appendices Contents Appendix A General Specifications .............................................................................................. A-2 Appendix B Electrical Specifications ............................................................................................ A-4 Appendix C Data Flow Between Ports ......................................................................................... A-8 Appendix D Star Network Topology ............................................................................................. A-9 Appendix E Interface Standards................................................................................................. A-10 Appendix F DIN Rail Mounting ................................................................................................... A-11 Appendix G Glossary of Terms .................................................................................................. A-12

MS-Connect 210 User’s Manual

A-1

Page 53

General Specifications

Appendix A, General Specifications Mechanical Mounting Hole Dimensions: 6.6” (168 mm) x 2.5” (63.5 mm) Full Length: 7.3” (184 mm) Width: 6.3” (160 mm) Height: 2.8” (71 mm) Weight: 1.6 lb. (726 g)

Environmental Enclosure: IP65 Humidity: Up to 90% (non-condensing) Operating Tempurature: 0° to 50°C (32° to 122°F) Storage Tempurature: -30° to 70°C (-22° to 158°F)

Electrical Power Requirements: 5.1 Watts (max.) w/ Display and Ethernet, 10-28VDC, 200mV p-p max. ripple Box Only: 32 mA Box + Display: 90 mA Box + Ethernet: 62 mA Box + Display + Ethernet: 120 mA @ 24VDC (typ.) Trigger, New Master, Input 1: 5 to 28V rated (6.5mA @ 24VDC) Output 1, 2, 3: Pass through: Optoisolated, 1-28V rated, (Ice<100mA max., must be limited by user) Relay: See Relay Module specifications. Minimum High

Low

Top

Maximum

Vin

4.5V

28V

Iin

4mA

7mA

Vin

0V

2V

Iin

0mA

1mA

Back

Connectors Reader: M23 19-pin circular socket connector Industrial Ethernet Connector: 8-pin M12 Micro-Change Trigger: 4-pin Micro-Change socket Power: 3-pin Micro-Change plug

CGBs Small: Access diameter range 0.18” to 0.39” (4.5 to 10 mm) Large: Access diameter range 0.2” to 0.5” (5 to 12.7 mm)

Side

Indicators Display: 2x20 alphanumeric characters LEDS: I/O status, Serial Beeper: Configurable

MS-Connect 210 Dimensions

Communication Protocols Standard Interfaces: RS-232, RS-422, Ethernet

Other Accessories Type: DIN Rail Kit, Pluggable Relay Modules

A-2

MS-Connect 210 User’s Manual

Page 54

Appendices FIS Options MS-Connect 210 with Display: FIS-0210-0001G MS-Connect 210 without Display: FIS-0210-0002G MS-Connect 210 with Ethernet + Display: FIS-0210-0003G

CE Mark General Immunity for Light Industry: EN 55024:1998 ITE Immunity Standard EN 61000-6-2:2001

Safety Certifications FCC, UL/cUL, CE, CB, RoHS/WEEE

©2014 Microscan Systems, Inc. All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes. Warranty–One year limited warranty on parts and labor. Extended warranty available.

MS-Connect 210 User Manual

A-3

Page 55

Electrical Specifications

Appendix B, Electrical Specifications Power: 55 Watts (max.)

Pluggable Relay Modules K1 K2 K3

Pluggable Series 70 Relay Module Pluggable Series 70 Relay Module Pluggable Series 70 Relay Module

Inputs / Outputs J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J13 J14 J15 J16

Input Power 10-28VDC Output Power 10-28VDC Chassis Output Power 10-28VDC Output Power 10-28VDC Output 1 Output 2 Output 3 RS-422/485 Trigger / New Master Input 1 Host RS-232 Aux RS-232 MS-Q 5VDC Spare

Jumpers JP1 JP2 JP3 JP10 JP11

Relay 1 Options Relay 2 Options Relay 3 Options New Master Button Lockout Trigger Button Lockout

Terminal Blocks Max. Rating J1 through J8 Wire Range Wire Strip Length

26 to 14 AWG. 11 mm

Wire Range Wire Strip Length

22 to 18 AWG. 5 mm

Max. Voltage Max. Current

28VDC 4 Amps

Max. Voltage Max. Current

240VAC 3 Amps

J9 through J15

J2 through J5

J6 through J8

Switches SW1 SW2 SW3 SW5 SW7

A-4

Power On / Off Reader Default Display Comm. Switches Reader Output Indicators Ethernet/RS-422/485 Control Switches

MS-Connect 210 User’s Manual

Page 56

Appendices 19-pin Reader Connector

Pin + CTS/RTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

RTS CTS

MS-Connect 210 User’s Manual

MS-Connect 210 Host RS-232 + Aux RS-232 + Aux RS-422/485 Output 1 (+) Output 2 (+) Output 3 (+) TX232 RX232 Power/Signal GND Trigger New Master RxD (–) Aux TxD TxD (+) Aux RxD RxD (+) Trigger/New Master/Input Common Output 2 (–) Output 3 (–) Default Input 1 TxD (–) Output 1 (–) Power (+)

+ Ethernet

Rx – Tx + Tx –

Rx +

A-5

Page 57

Electrical Specifications

Optoisolator Outputs Optoisolator circuits can transfer pulses between the wiring box and peripherals with no direct connection to the internal circuitry. However, not every optoisolator configuration provides complete isolation. The diagrams below show fully optoisolated and non-optoisolated circuits. Note: The table below only shows delays for the MS-Connect 210. Refer to the connected reader’s specifications for additional delay information. Iload =5mA

Iload =50mA

V Out-Ona

0.05V

0.6V

Iload =100mA 1.2V t On-Typ

0.7ms

0.9ms

1.1ms t Off-Typ

1.6ms

1.5ms

1.5ms a. Voltage drop across output when activated.

Output Circuit Examples Note: The following internal optoisolator examples do not represent all possible configurations. Refer to original manufacturer’s specifications for any output modules that are installed. Fully Optoisolated This circuit is fully optoisolated and is the recommended configuration. It allows the user to apply 1 – 28 VDC to the circuit. Caution: The maximum current that can pass through the optoisolator is 100mA.

Isolated

Host Power (+) 1 to 28 V

Scanner

Outputs (+)

Output

Input Outputs (–) Power ground

Grounded (Not Optoisolated) In this diagram, power is applied externally, but the power ground is used to complete the circuit. This setup involves some risk to the optoisolator if excessive voltages are applied. Caution: The maximum current that can pass through the optoisolator is 100mA.

Power (+) 1 to 28 V Scanner

Outputs (+)

Output

Input Outputs (–)

Power ground

Additional Isolated Output Circuit Examples Secondary Relay 1 to 28 V RELAY

Isolated

Isolated Power +

Power + Scanner

Outputs (+)

Scanner Output

Outputs (+)

PLC V

PLC

Input

Output Outputs (–)

Outputs (–)

PLC GND

Power ground

Power ground

A-6

MS-Connect 210 User’s Manual

Page 58

Appendices

Optoisolator Inputs All discrete inputs can be fully isolated pulses as PNP or NPN circuits. Minimum

Maximum

VIN-HIGH/IIN-HIGH

4.5 V/4.0mA

28 V/7mA

VIN-LOW/IIN-LOW

0 V/0mA

2.0V/1mA

5V

24V t On

8µs

4 µs t Off

20µs

30µs

Input (+) I load Input (–)

Input Examples Important: The following examples do not represent all possible wiring configurations. Fully Optoisolated PNP Source +V

Isolated V CC

NPN Source (trigger only)

Isolated V CC

+V Input (+)

Signal Input (+)

Input (–)

Input (–)

Signal

Not Optoisolated PNP Source

Non-isolated V CC

Power (+)

+V

Input (+)

V CC Signal

NPN Source (trigger only)

Non-isolated Power (+)

+V

Input (+) Input (–)

Input (–) Power ground

Signal

Power ground

MS-Connect 210 User’s Manual

A-7

Page 59

Data Flow Between Ports

Appendix C, Data Flow Between Ports The following diagrams demonstrate how data moves between an MS-Connect 210 display, an RS-232 cabled reader, a handheld, a host computer, and the Ethernet gateway. Initiated from Reader Reader RS-232

Ethernet Gateway Handheld RS-232 RS-232 Host Display

Initiated from Handheld Handheld RS-232

Ethernet Gateway Reader RS-232 RS-232 Host Display

Initiated from Host RS-232 Host

Ethernet Gateway Handheld RS-232 Reader RS-232 Display

Initiated from Ethernet Ethernet Gateway

Reader RS-232 Handheld RS-232 RS-232 Host Display

A-8

MS-Connect 210 User’s Manual

Page 60

Appendices

Appendix D, Star Network Topology A star network is a local area network (LAN) that directly connects multiple workstations, or nodes, to a central computer. All workstations on the network are indirectly connected to each other through the central computer. Star networks allow multiple workstations to communicate from scattered locations throughout a large physical area. The illustration below shows a simplified model of a star topology. The large center sphere represents the central computer, and the five smaller spheres represent workstations on the network. The straight lines represent cabling. workstations workstations central computer

One of the main advantages of the star network topology commonly used in EtherNet/IP is that a cable failure isolates a single workstation instead of affecting the entire network. In addition, the isolation of a single node makes the diagnostic process relatively simple.

MS-Connect 210 User’s Manual

A-9