Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 7

MS-Connect 210 User Manual, pages 1 to 10

Pages 1 to 10 of 65

The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-Connect 210

Page 1 read from a scan by OCR; it may hold reading errors

MICROSCAN.

MS-Connect 210 User Manual

P/N 84-210210 RevA

Page 2

Copyright and Disclaimer Copyright ©2014 Microscan Systems, Inc. Tel: +1.425.226.5700 / 800.762.1149 Fax: +1.425.226.8250 All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Microscan manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Microscan. Throughout this manual, trademarked names might be used. We state herein that we are using the names to the benefit of the trademark owner, with no intention of infringement.

Disclaimer The information and specifications described in this manual are subject to change without notice.

Latest Manual Version For the latest version of this manual, see the Download Center on our web site at: www.microscan.com.

Technical Support For technical support, e-mail: helpdesk@microscan.com.

Warranty For current warranty information, see: www.microscan.com/warranty.

Microscan Systems, Inc. United States Corporate Headquarters +1.425.226.5700 / 800.762.1149 United States Northeast Technology Center +1.603.598.8400 / 800.468.9503 European Headquarters +31.172.423360 Asia Pacific Headquarters +65.6846.1214 ii

MS-Connect 210 User Manual

Page 3

Introduction

Table of Contents Chapter 1

Setting Up the Device

Check Required Hardware ...................................................................... 1-2 Configure the Display .............................................................................. 1-4 Connect the System ................................................................................ 1-5 Configure Output Settings ..................................................................... 1-14 Power-On the MS-Connect 210 ............................................................ 1-19 Install ESP ............................................................................................. 1-20 Select and Identify the MS-Connect 210 ............................................... 1-21

Chapter 2

Using Ethernet

Power-On the System ............................................................................. 2-2 Select and Identify the MS-Connect 210 ................................................. 2-3 Set Network Parameters ......................................................................... 2-4 Set COM Port Parameters....................................................................... 2-6 Select Reader Model and Connect.......................................................... 2-7 Configure the Connected Reader ............................................................ 2-8 Configuring the Ethernet Port .................................................................. 2-9 Ethernet Port Custom Features ............................................................. 2-11 Ethernet Port Operation......................................................................... 2-14 EtherNet/IP Serial Interface (Class 0x68).............................................. 2-15 Input (T –>O) Assembly Object (Class 0x04, Instance 0x64)................ 2-18 Output (O –>T) Assembly Object (Class 0x04, Instance 0x65) ............. 2-18 Configuration Assembly Object (Class 0x04, Instance 0x80)................ 2-18 Service-Object Summary....................................................................... 2-18 RSLogix Examples ................................................................................ 2-19 EIPScan Examples ................................................................................ 2-21 TFTP Services ....................................................................................... 2-22

Appendices Appendix A General Specifications .........................................................A-2 Appendix B Electrical Specifications .......................................................A-4 Appendix C Data Flow Between Ports ....................................................A-8 Appendix D Star Network Topology ........................................................A-9 Appendix E Interface Standards ............................................................A-10 Appendix F DIN Rail Mounting ..............................................................A-11 Appendix G Glossary of Terms .............................................................A-12

MS-Connect 210 User’s Manual iii

Page 4

About the MS-Connect 210

About the MS-Connect 210 The key features of the MS-Connect 210 are: • Easy Ethernet configuration with ESP® Software • Ethernet TCP/IP and EtherNet/IP™ • Trigger and New Master controls on external button panel • Output indicator LEDs • Easy-to-access ports, Micro-Change connectors, and cabling routes • Clearly labeled terminal blocks • Spacious interior for easy wiring access • Convenient quick-reference insert with default settings and output options • Easy mounting, with available DIN rail option • Ultra-bright alphanumeric display (with FIS-0210-0001G and FIS-0210-0003G models)

About This Manual This User’s Manual provides complete information on setting up the MS-Connect 210 and using it in an application setting. The information is presented in the order that the MS-Connect 210 might be set up and made ready for operation.

Highlighting Cross-references and web links are highlighted in blue bold. Menu topics and other points of emphasis are highlighted in Bold Initial Caps. References to the titles of external documents are italicized.

iv

MS-Connect 210 User’s Manual

Page 5

Introduction

Product Labels The following labels are located on the MS-Connect 210: WEEE (Waste Electronic and Electrical Equipment) label.

Product ID, serial number, date of manufacture, FIS number, electrical and safety information.

MS-Connect 210 User’s Manual v

Page 6

Statement of Agency Compliance

Statement of Agency Compliance The MS-Connect 210 has been tested for compliance with FCC (Federal Communications Commission) regulations and has been found to conform to all applicable FCC Rules and Regulations. To comply with FCC RF exposure compliance requirements, this device must not be co-located or operate in conjunction with any other antenna or transmitter. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

The MS-Connect 210 has been tested for compliance with CE (Conformité Européenne) standards and guidelines, and has been found to conform to applicable CE standards, specifically EN 55024:1998 ITE Immunity Standard and EN 61000-6-2:2001. The MS-Connect 210 has been tested by an independent electromagnetic compatibility laboratory in accordance with the applicable specifications and instructions.

vi

MS-Connect 210 User’s Manual

Page 7

Introduction

Statement of RoHS Compliance All Microscan readers with a ‘G’ suffix in the FIS number are RoHS-Compliant. All compliant readers were converted prior to March 1, 2007. All standard accessories in the Microscan Product Pricing Catalog are RoHS-Compliant except 20-500013-01 and 98-000039-02. These products meet all the requirements of “Directive 2002/95/EC” European Parliament and the Council of the European Union for RoHS compliance. In accordance with the latest requirements, our RoHS-Compliant products and packaging do not contain intentionally added Deca-BDE, Perfluorooctanes (PFOS) or Perfluorooctanic Acid (PFOA) compounds above the maximum trace levels. To view the document stating these requirements, please visit: http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=CELEX:32002L0095:EN:HTML and http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2006:372:0032:0034:EN:PDF

Please contact your sales manager for a complete list of Microscan’s RoHS-Compliant products. This declaration is based upon information obtained from sources which Microscan believes to be reliable, and from random sample testing; however, the information is provided without any representation of warranty, expressed or implied, regarding accuracy or correctness. Microscan does not specifically run any analysis on our raw materials or end product to measure for these substances. The information provided in this certification notice is correct to the best of Microscan’s knowledge at the date of publication. This notice is not to be considered a warranty or quality specification. Users are responsible for determining the applicability of any RoHS legislation or regulations based on their individual use of the product. In regards to “RoHS Directive 2011_65_EU” Microscan produces Monitoring and Control Instruments as well as Industrial Monitoring & Control Instruments as defined within the directive. Microscan has developed and is implementing a RoHS2 compliance plan with the intention of bringing all active products listed in our current marketing literature within full compliance as per the directive deadlines. Key milestones for the transition plan are as follows: • Complete internal product audit by July 2014. • Initial “Monitoring and Control Instruments” RoHS2 compliant products available by December 2014 • Initial “Industrial Monitoring & Control Instruments” RoHS2 compliant products available by July 2015 • All new products introduced in 2015 are expected to be WEEE & RoHS2 compliant. Microscan will mark the products with the ‘CE’ marking that complies with the RoHS2 process to acquire ‘CE’ certification per the example given: Example >> Machinery directive + EMC directive + RoHS2 = Declaration of Conformity.

MS-Connect 210 User Manual vii

Page 8

1 Setting Up the Device Contents Check Required Hardware............................................................................................................ 1-2 Configure the Display.................................................................................................................... 1-4 Connect the System...................................................................................................................... 1-5 Configure Output Settings........................................................................................................... 1-14 Power-On the MS-Connect 210.................................................................................................. 1-19 Install ESP .................................................................................................................................. 1-20 Select and Identify the MS-Connect 210 .................................................................................... 1-21

This section is designed to get your MS-Connect 210 up and running quickly. Following these steps will allow you to get a sense of the product’s capabilities while you set it up for active operation.

MS-Connect 210 User’s Manual

1-1

Page 9

Check Required Hardware

Check Required Hardware Stand-Alone Configuration Item 1 2 3

Description

Part Number

MS-Connect 210 Connectivity Box with Display MS-Connect 210 Connectivity Box MS-Connect 210 Connectivity Box with Display and Ethernet

FIS-0210-0001G FIS-0210-0002G FIS-0210-0003G

Microscan Reader (10-28V or 5V)

FIS-XXXX-XXXXG

Power Supply (10-28V)

97-100004-15

Reader Cable, 19-pin to 25-pin, Host RS-422/485 Reader Cable, 19-pin to 25-pin, Host RS-232, Aux RS-232 Reader Cable, 19-pin to 25-pin, Ethernet Reader Cable, 19-pin to 15-pin, Host RS-232 (5V readers and MS-9)* Reader Cable, 19-pin to 15-pin, Host RS-422/485 (5V readers and MS-9)* Reader Cable, 19-pin to 15-pin, Host RS-232 Reader Cable, 19-pin to 15-pin, Host RS-422/485

61-000122-01 61-000123-01 61-000124-01 61-000127-02 61-000139-01 61-000121-02 61-000138-01

7

MS-Q Reader Cable (optional; must be stripped before wiring)

61-000066-02

8

Internal Ethernet Cable (optional), 8-pin M12 external Micro-Change to RJ45 Ethernet module connector

61-000128-01

9 10 11 12 13

Industrial Ethernet Cable (optional), 8-pin M12 Micro-Change

User-supplied

14

Pluggable Relay Module, 120VAC, Series 70, Type SM (optional; not shown) Pluggable Relay Module, 240VAC, Series 70, Type SM (optional; not shown) Pluggable Relay Module, 24VDC, Series 70, Type SM (optional; not shown)

4 5 6

15 16 17

IC-332 Power Adapter (5V readers)

FIS-0001-0035G

Object Detector (optional)

99-000017-02

Host Cable (pre-stripped to 9-pin)

61-000105-01

Ethernet Cable (optional), RJ45

User-supplied

DIN Rail Mounting Kit (optional; not shown)

98-000013-04 98-000013-05 98-000013-06 98-000093-01

*IC-332 not required with MS-9.

Hardware Required for Stand-Alone Configuration

1-2

MS-Connect 210 User’s Manual

Page 10

Setup and Operation

Check Required Hardware (cont.) Multidrop and Daisy Chain Configurations Item 1 2 3

Description

Part Number

MS-Connect 210 Connectivity Box with Display MS-Connect 210 Connectivity Box MS-Connect 210 Connectivity Box with Display and Ethernet

FIS-0210-0001G FIS-0210-0002G FIS-0210-0003G

Microscan Reader (10-28V or 5V)

FIS-XXXX-XXXXG

Power Supply (10-28V)

97-100004-15

Reader Cable, 19-pin to 25-pin, Host RS-422/485 Reader Cable, 19-pin to 25-pin, Host RS-232, Aux RS-232 Reader Cable, 19-pin to 25-pin, Ethernet Reader Cable, 19-pin to 15-pin, Host RS-232 (5V readers and MS-9)* Reader Cable, 19-pin to 15-pin, Host RS-422/485 (5V readers and MS-9)* Reader Cable, 19-pin to 15-pin, Host RS-232 Reader Cable, 19-pin to 15-pin, Host RS-422/485

61-000122-01 61-000123-01 61-000124-01 61-000127-02 61-000139-01 61-000121-02 61-000138-01

7

MS-Q Reader Cable (optional; not shown; must be stripped before wiring)

61-000066-02

8

Internal Ethernet Cable (optional), 8-pin M12 external Micro-Change to RJ45 Ethernet module connector

61-000128-01

9

MS-Connect 210 Industrial Ethernet Cable (optional), 8-pin M12 Micro-Change

User-supplied

10

MS-Connect 210 Multidrop / Daisy Chain Cable (must be stripped and wired to MS-Connect 210’s RS-422 terminal blocks)

User-supplied

11 12 13 14 15

MS-Connect 5100 USB Programming Cable, Type A to Type B, 6 ft.

61-000112-01

16

Pluggable Relay Module, 120VAC, Series 70, Type SM (optional; not shown) Pluggable Relay Module, 240VAC, Series 70, Type SM (optional; not shown) Pluggable Relay Module, 24VDC, Series 70, Type SM (optional; not shown)

4 5 6

17 18 19

MS-Connect 5100 Host Cable, 9-pin to RJ12, 6 ft.

61-000108-01

MS-Connect 5100 Concentrator Cable, user-stripped to RJ45

User-supplied

IC-332 Power Adapter (5V readers)

FIS-0001-0035G

Object Detector (optional)

99-000017-02

DIN Rail Mounting Kit (optional; not shown)

98-000013-04 98-000013-05 98-000013-06 98-000093-01

*IC-332 not required with MS-9.

Hardware Required for Multidrop or Daisy Chain Configuration MS-Connect 210 User’s Manual

1-3