Page 11

Configure the Display

Configure the Display If you are using a version of the MS-Connect 210 with an alphanumeric character display (FIS-0210-0001G or FIS-0210-0003G), you must configure the display before applying power to the system. For the MS-Connect 210’s display to operate correctly, all communication settings must match those of the reader. Settings can be matched using the dip switches located on the board at SW3.

Display Communication Dip Switches

Important: The dip switches located at SW4 on the board are FOR FACTORY USE ONLY and should not be moved.

Display Communication Dip Switches* BAUD RATE

DATA BITS

SWITCH 9.6K 19.2K 38.4K 57.6K 115.2K 7 1 OFF ON ON ON ON 2 ON OFF OFF ON ON 3 ON OFF ON OFF ON 4-5 NOT USED 6 7 8

8

PARITY EVEN/ODD NONE

CLEAR SCREEN YES NO

ON**

OFF

OFF ON ON

OFF

* Settings must match reader. Default settings shown in bold italics. ** Sends a Form Feed command (0x0C) to the display, clearing the screen whenever the MS-Connect 210 receives new data. The reader’s Preamble must be set to 0x0C for Clear Screen to function.

Once the MS-Connect 210’s dip switches are configured to match reader settings, decoded symbol data and other information will display correctly during operation of the system. Note: Power must be cycled to the MS-Connect 210 each time the dip switch settings for baud rate are changed. 1-4

MS-Connect 210 User’s Manual

Page 12

Setup and Operation

Connect the System There are a number of different ways to connect a reader, the MS-Connect 210, and a host. The 19-pin reader connector; the Micro-Change connectors for the power supply, optional Ethernet, and optional object detector; and three CGBs are located at the back of the unit. 8-pin M12 Industrial Ethernet Micro-Change Connector (optional) CGBs

Large CGB accomodates RJ45 Ethernet connector

19-pin Reader Connector

Power Micro-Change Connector

Trigger Micro-Change Connector

MS-Connect 210 Connectors

Connecting a 10-28 Volt Reader to the MS-Connect 210 If you are using an MS-9, QX-830, QX-870, or MS-890: 1. Attach the 19-pin to 25-pin Reader Cable to the MS-Connect 210 via the 19-pin reader connector, shown in the illustration above. Important: The MS-9 requires a 19-pin to 15-pin Reader Cable. 2. Tighten the cable housing at the 19-pin reader connector on the back of the MS-Connect 210 unit. 3. Attach cabling inside the wiring box. 4. Attach an Object Detector (optional) to the MS-Connect 210 via the trigger Micro-Change connector, shown in the illustration above. 5. Attach the Power Supply to the MS-Connect 210 via the power Micro-Change connector, shown in the illustration above. CAUTION: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

MS-Connect 210 User’s Manual

1-5

Page 13

Connect the System

Connecting a 5-Volt Reader to the MS-Connect 210 If you are using an MS-1, MS-2, MS-3, MS-4, Quadrus MINI, Quadrus MINI 3, or Quadrus MINI Velocity: 1. Attach the 19-pin to 15-pin Reader Cable to the MS-Connect 210 via the 19-pin reader connector, shown in the illustration below. 2. Tighten the cable housing at the 19-pin reader connector on the back of the MS-Connect 210 unit. 3. Attach the 15-pin end of the Reader Cable to the 10-28VDC end of the IC-332 Power Adapter, and attach the reader’s cable to the 5VDC end of the IC-332 Adapter. Important: Reversing the IC-332 in this configuration may seriously damage the interface. 4. Attach cabling inside the wiring box. 5. Attach an Object Detector (optional) to the MS-Connect 210 via the trigger Micro-Change connector, shown in the illustration below. 6. Attach the Power Supply to the MS-Connect 210 via the power Micro-Change connector, shown in the illustration below. CAUTION: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

8-pin M12 Industrial Ethernet Micro-Change Connector (optional) CGBs

Large CGB accomodates RJ45 Ethernet connector

19-pin Reader Connector

Power Micro-Change Connector

Trigger Micro-Change Connector

MS-Connect 210 Connectors

1-6

MS-Connect 210 User’s Manual

Page 14

Setup and Operation

Connecting an MS-Q Imager to the MS-Connect 210 Once you have a reader connected to the MS-Connect 210 by RS-232, you can simultaneously connect an MS-Q by wiring it directly to the MS-Q terminal block inside the box (J15). 1. Unscrew one of the three CGB caps at the back of the unit. 2. Clear the CGB’s access hole to create a cabling route into the box. 3. Pass a pre-stripped MS-Q Reader Cable (61-000066-02 or user-supplied) through the access hole so that the reader connector is outside the box and the end to be wired is inside the box.

To inside of wiring box

4. Wire the MS-Q Reader Cable to the MS-Q terminal block (J15). • Wire +5V to Pin 1 (VIN; red) • Wire TX232 to Pin 2 (RS-232 Transmit; brown) • Wire RX232 to Pin 3 (RS-232 Receive; orange) • Wire HH GND to Pin 5 (Ground; black)

MS-Connect 210 User’s Manual

MS-Q Reader Cable (61-000066-02 or user-supplied)

1-7

Page 15

Connect the System

Connecting the MS-Connect 210 to a Host Once you have a reader connected to the MS-Connect 210 by RS-232, you have the option of connecting the MS-Connect 210 to a host computer. 1. Unscrew one of the three CGB caps at the back of the unit. 2. Clear the CGB’s access hole to create a cabling route into the box. 3. Pass a pre-stripped RS-232 Host Cable (P/N 61-000105-01) through the access hole so that the 9-pin connector is outside the box, and the end to be wired is inside the box. 4. Wire the Host Cable to the “Host RS-232” terminal block (J13). Important: Refer to the label on the Host Cable (61-000105-01) for color-coded pin assignments. 5. Connect the Host Cable to the host’s RS-232 port.

• Wire CHASSIS to Host Cable Shield Wire • Wire TX232 to Host Receive, Pin 2 • Wire RX232 to Host Transmit, Pin 3 • Wire SGNL GND to Host Ground, Pin 5

Connection ID label

Host Cable (61-000105-01)

1-8

MS-Connect 210 User’s Manual

Page 16

Setup and Operation

Connecting the MS-Connect 210 to a Multidrop Network Once you have a reader connected to the MS-Connect 210 by RS-232, you have the option of connecting the MS-Connect 210 and reader to a Multidrop network.

Important: Before connecting to a Multidrop network, be sure that all four switches at SW7 are in the UP position. This closes the circuits to allow Multidrop communication.

Multiple MS-Connect 210s and readers can be added to a Multidrop network (one reader per MS-Connect 210).

Multidrop Concentrator

MS-Connect 210 User’s Manual

To other MS-Connect 210s and readers in the Multidrop network

1-9

Page 17

Connect the System

Connecting the MS-Connect 210 to Ethernet Once you have a reader connected to the MS-Connect 210 by RS-232, you have the option of connecting the MS-Connect 210 and reader to Ethernet. The Optional Ethernet Module converts RS-232 to Ethernet for readers without embedded Ethernet.

Important: Before connecting to Ethernet using the Reader Ethernet port, be sure that all four switches at SW7 are in the DOWN position. This opens the circuits to create a pass through condition. The Reader Ethernet port is intended for readers that have embedded Ethernet.

See Chapter 2, Using Ethernet, for more detail about how to configure the MS-Connect 210 for Ethernet operation.

1-10

MS-Connect 210 User’s Manual

Page 18

Setup and Operation

Using the Internal Ethernet Cable The optional internal Ethernet cable (61-000128-01) provides a quick, water-tight connection to an Ethernet network.

The 8-pin M12 Micro-Change end of the internal Ethernet cable is externally visible. The RJ45 end of the cable is inside the box, and can be connected to either of the Ethernet modules highlighted below.

MS-Connect 210 User’s Manual

1-11

Page 19

Connect the System

Using Input 1 The Input 1 terminal block (J11) allows you to wire buttons or other external devices for resetting counters, unlatching outputs, or other application requirements. Wire the external device to the Input 1 terminal block at J11.

The Input 1 LED will illuminate to signal a switching event.

1-12

MS-Connect 210 User’s Manual

Page 20

Setup and Operation

Powering Additional Readers from the Terminal Blocks The MS-Connect 210 can power up to three additional readers during active operation. This is accomplished by wiring the additional readers to terminal blocks J2 through J5 inside the box, as shown below. Note: If you are using MS-890s, the MS-Connect 210 can power up to two additional readers, due to the greater power demands of those products. The primary reader, or Reader 1, is powered through the 19-pin reader connector at the back of the unit.

MS-Connect 210 Power Supply Micro-Change Connector

Terminal Blocks J2 - J5

Reader 2 Connect the positive wire of the reader’s Reader Cable to J2 PWR+ (Pin 1), the negative wire to J2 PWR- (Pin 2), and the Chassis GND wire to J3 (Pin 3). Reader 3 Connect the positive wire of the reader’s Reader Cable to J4 PWR+ (Pin 1), the negative wire to J4 PWR- (Pin 2), and the Chassis GND wire to J3 (Pin 2). Reader 4 Connect the positive wire of the reader’s Reader Cable to J5 PWR+ (Pin 1), the negative wire to J5 PWR- (Pin 2), and the Chassis GND wire to J3 (Pin 1).

MS-Connect 210 User’s Manual

1-13