A two-page spec sheet (SP022H-EN-1013, 2015) for the Microscan MS-Connect 210, an IP65 wiring and connectivity box for Microscan laser scanners and 2D imagers. It lists the connectors, terminal block ratings, environmental limits and dimensions, and options such as the display, relay modules and DIN rail kit.
- Device
- Factory floor wiring box that connects Microscan laser scanners and 2D imagers to a host by serial or Ethernet p. 1
- Host interfaces
- RS-232 and RS-422 serial; Ethernet TCP/IP and EtherNet/IP p. 1, 2
- Connectors
- Reader: M23 19-pin circular socket; trigger: 4-pin MicroChange socket; power: 3-pin MicroChange plug; Ethernet: 8-pin M12 MicroChange socket p. 2
- Power
- 10-28 V; can also power three additional readers p. 1, 2
- Display
- Optional, 2 x 20 alphanumeric characters, showing two lines of decoded information p. 1, 2
- Dimensions
- 7.3 in. (184 mm) long, 6.3 in. (160 mm) wide, 2.8 in. (71 mm) high; 1.6 lb. (726 g) p. 2
- Environment
- Operating 0 to 50° C (32 to 122°F); storage -30 to 70° C (-22 to 158°F); humidity up to 90% non-condensing; IP65 enclosure p. 2
- Terminal wire range
- J1-J8: 26 to 14 AWG, 11 mm strip; J9-J15: 22 to 18 AWG, 5 mm strip p. 2
- Terminal ratings
- J2-J5: 28 VDC, 4 Amps max.; J6-J8: 240 VAC, 3 Amps max. p. 2
- Relay modules
- Slots K1 to K3 for optional pluggable relay modules, for external devices such as light stacks p. 1, 2
- Accessories
- DIN rail kit, relay modules p. 2
- Cable access
- Small holes 0.18 to 0.39 in. (4.5 to 10 mm), large 0.2 to 0.5 in. (5 to 12.7 mm) p. 2
- Mounting
- Four through-holes for mounting screws; optional plate for DIN rail mounting p. 1
What this sheet walks you through
- Routing input and output wiring through the access holes to the terminal blocks p. 1
- Terminal blocks, jumpers and switches inside the box p. 2
Questions this sheet answers
What voltage does the Microscan MS-Connect 210 need?
10-28 V, fed to the J1 input power terminal. p. 2
Does the MS-Connect 210 support EtherNet/IP?
Yes, the spec sheet says Ethernet TCP/IP and EtherNet/IP are available out of the box. p. 1
What connector does the reader plug into on the MS-Connect 210?
An M23 19-pin circular socket connector. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
MS–Connect 210
Optional Display Visible I/O Indicators
Accessible Connectors
Optional Ethernet Access Port
MS–Connect 210: Easy Integration
- For fast installation and easy maintenance of any Microscan scanner or imager
- IP65 rated industrial design
- Better organization of cables and wiring on factory floor
Connectivity Solution with Ethernet The MS-Connect 210 simplifies connectivity of Microscan readers in industrial applications. This factory floor ready wiring box features a vivid display, convenient access holes for easy wire routing, and multiple connectivity options including Ethernet protocols. The MS-Connect 210 is the ideal Microscan reader accessory for any users seeking an easy connectivity option. Ethernet Connectivity Connect to a host using serial or Ethernet connection. Ethernet TCP/IP and EtherNet/IP protocols are available out of the box. Informative Display Providing two lines of decoded information, the optional display is ultra-bright and easy to read.
- Protocol conversion allows connection via Ethernet
Simple Connectivity Solution for: Microscan laser barcode scanners
Microscan 2D barcode imagers
For more information on this product, visit www.microscan.com.
I/O Indicators The front panel on the MS-Connect 210 provides visual confirmation of performance. Multiple colors are used for easy recognition. Relay Modules The MS-Connect 210 includes slots for optional relay modules to allow for greater use of external devices including light stacks.
Practical Design Four access holes located on the box allow users quick, easy, and clean wiring of inputs and outputs. Mounting is simplified with four accessible throughholes for mounting screws. An optional plate is available for easy DIN rail mounting. Clear Wiring Path Wiring to the appropriate terminal block is easily accomplished, due to the access holes and a clear area located between the terminal rows. Additional Power The MS-Connect 210 includes the option to power three additional readers.
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
MS−Connect 210 Specifications and Options MS-CONNECT 210 INTERNAL VIEW
TOPSIDEBACKCONNECTORS
CE MARK General Immunity for Heavy Industry: EN 55024: 1998 ITE Immunity Standard EN 61000-6-2-:2001
Reader: M23 19-pin circular socket connector Trigger: 4-pin MicroChange socket Power: 3-pin MicroChange plug
EMISSIONSOTHER ACCESSORIESINDICATORS
Type: DIN rail kit, Relay modules Industrial Ethernet Connector: 8-pin M12 MicroChange socket
Digital Display: 2X20 Alphanumeric characters Beeper: Configurable LEDs: I/O status, Serial
SAFETY CERTIFICATIONS DESIGNED FOR
EN 55022:1998 Class A
MECHANICAL Length: 7.3” (184 mm) Width: 6.3” (160 mm) Height: 2.8” (71 mm) Weight: 1.6 lb. (726 g)
ENVIRONMENTAL Enclosure: IP65 Humidity: up to 90% (non-condensing) Operating Temperature: 0° to 50° C (32° to 122°F) Storage Temperature: -30° to 70° C (-22° to 158°F)
ELECTRICAL
TERMINAL BLOCKS MAX RATING J1-J8 Wire Range: 26 to 14 AWG. Wire Strip Length: 11 mm J9-J15 Wire Range: 22 to 18 AWG. Wire Strip Length: 5 mm J2-J5 Max Voltage: 28 VDC. Max Current: 4 Amps J6-J8 Max Voltage: 240 VAC. Max Current: 3 Amps
Power: 10-28 V
COMMUNICATION PROTOCOLS
PLUGGABLE RELAY MODULEACCESS CGBK1Pluggable Relay ModuleK2Pluggable Relay ModuleK3Pluggable Relay Module
Standard Interface: RS-232, RS-422
FCC, UL/cUL, CE, BSMI
ROHS/WEEE COMPLIANT ISO CERTIFICATION
Certified ISO 9001:2008 Quality Management System ©2015 Microscan Systems, Inc. SP022H-EN-1013 Warranty–For current warranty information on this product, please visit www.microscan.com/warranty.
Small: Access diameter range 0.18” to 0.39” (4.5 to 10 mm) Large: Access diameter range 0.2” to 0.5” (5 to 12.7 mm)
INPUTS/OUTPUTS J1Input Power 10-28 VDCJ2Output Power 10-28 VDCJ3ChassisJUMPERSJ4Output Power 10-28 VDCJP1Relay Output 1 OptionsJ5Output Power 10-28 VDCJP2Relay Output 2 OptionsJ6Output 1JP3Relay Output 3 OptionsJ7Output 2JP 11Trigger Button LockoutJ8Output 3JP 10
New Master Button Lockout
Microscan Systems Inc. Tel 425 226 5700 / 800 251 7711 Fax 425 226 8250
Microscan EuropeJ9RS 422/485J10Trigger/New MasterJ11Input 1SW1On/OffJ13Host RS-232SW2Reader Default
Tel 65 6846 1214 / Fax 65 6846 4641
J14Aux RS 232SW3Display Comm SwitchesJ15MS-Q 5 VDCSW5
Reader Output Indicators
www.microscan.comJ16SpareSW7Reader Ethernet Option
Tel 31 172 423360 / Fax 31 172 423366
SWITCHES
Microscan Asia Pacific
Product Information: info@microscan.com Technical Support: helpdesk@microscan.com