A two-page spec sheet (SP022H-EN-1013, 2015) for the Microscan MS-Connect 210, an IP65 wiring and connectivity box for Microscan laser scanners and 2D imagers. It lists the connectors, terminal block ratings, environmental limits and dimensions, and options such as the display, relay modules and DIN rail kit.

Device
Factory floor wiring box that connects Microscan laser scanners and 2D imagers to a host by serial or Ethernet p. 1
Host interfaces
RS-232 and RS-422 serial; Ethernet TCP/IP and EtherNet/IP p. 1, 2
Connectors
Reader: M23 19-pin circular socket; trigger: 4-pin MicroChange socket; power: 3-pin MicroChange plug; Ethernet: 8-pin M12 MicroChange socket p. 2
Power
10-28 V; can also power three additional readers p. 1, 2
Display
Optional, 2 x 20 alphanumeric characters, showing two lines of decoded information p. 1, 2
Dimensions
7.3 in. (184 mm) long, 6.3 in. (160 mm) wide, 2.8 in. (71 mm) high; 1.6 lb. (726 g) p. 2
Environment
Operating 0 to 50° C (32 to 122°F); storage -30 to 70° C (-22 to 158°F); humidity up to 90% non-condensing; IP65 enclosure p. 2
Terminal wire range
J1-J8: 26 to 14 AWG, 11 mm strip; J9-J15: 22 to 18 AWG, 5 mm strip p. 2
Terminal ratings
J2-J5: 28 VDC, 4 Amps max.; J6-J8: 240 VAC, 3 Amps max. p. 2
Relay modules
Slots K1 to K3 for optional pluggable relay modules, for external devices such as light stacks p. 1, 2
Accessories
DIN rail kit, relay modules p. 2
Cable access
Small holes 0.18 to 0.39 in. (4.5 to 10 mm), large 0.2 to 0.5 in. (5 to 12.7 mm) p. 2
Mounting
Four through-holes for mounting screws; optional plate for DIN rail mounting p. 1

What this sheet walks you through

  • Routing input and output wiring through the access holes to the terminal blocks p. 1
  • Terminal blocks, jumpers and switches inside the box p. 2

Questions this sheet answers

What voltage does the Microscan MS-Connect 210 need?

10-28 V, fed to the J1 input power terminal. p. 2

Does the MS-Connect 210 support EtherNet/IP?

Yes, the spec sheet says Ethernet TCP/IP and EtherNet/IP are available out of the box. p. 1

What connector does the reader plug into on the MS-Connect 210?

An M23 19-pin circular socket connector. p. 2

Can the MS-Connect 210 mount on a DIN rail?

Yes, with the optional DIN rail plate (DIN rail kit). p. 1, 2

The file

Size and text

Pages2
PDF448 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Microscan MS-Connect 210 Spec Sheet

The text of page 1, from the PDF itself

MS–Connect 210

Optional Display Visible I/O Indicators

Accessible Connectors

Optional Ethernet Access Port

MS–Connect 210: Easy Integration

  • For fast installation and easy maintenance of any Microscan scanner or imager
  • IP65 rated industrial design
  • Better organization of cables and wiring on factory floor

Connectivity Solution with Ethernet The MS-Connect 210 simplifies connectivity of Microscan readers in industrial applications. This factory floor ready wiring box features a vivid display, convenient access holes for easy wire routing, and multiple connectivity options including Ethernet protocols. The MS-Connect 210 is the ideal Microscan reader accessory for any users seeking an easy connectivity option. Ethernet Connectivity Connect to a host using serial or Ethernet connection. Ethernet TCP/IP and EtherNet/IP protocols are available out of the box. Informative Display Providing two lines of decoded information, the optional display is ultra-bright and easy to read.

  • Protocol conversion allows connection via Ethernet

Simple Connectivity Solution for: Microscan laser barcode scanners

Microscan 2D barcode imagers

For more information on this product, visit www.microscan.com.

I/O Indicators The front panel on the MS-Connect 210 provides visual confirmation of performance. Multiple colors are used for easy recognition. Relay Modules The MS-Connect 210 includes slots for optional relay modules to allow for greater use of external devices including light stacks.

Practical Design Four access holes located on the box allow users quick, easy, and clean wiring of inputs and outputs. Mounting is simplified with four accessible throughholes for mounting screws. An optional plate is available for easy DIN rail mounting. Clear Wiring Path Wiring to the appropriate terminal block is easily accomplished, due to the access holes and a clear area located between the terminal rows. Additional Power The MS-Connect 210 includes the option to power three additional readers.

Page 2 of Microscan MS-Connect 210 Spec Sheet

The text of page 2, from the PDF itself

MS−Connect 210 Specifications and Options MS-CONNECT 210 INTERNAL VIEW

TOPSIDEBACKCONNECTORS

CE MARK General Immunity for Heavy Industry: EN 55024: 1998 ITE Immunity Standard EN 61000-6-2-:2001

Reader: M23 19-pin circular socket connector Trigger: 4-pin MicroChange socket Power: 3-pin MicroChange plug

EMISSIONSOTHER ACCESSORIESINDICATORS

Type: DIN rail kit, Relay modules Industrial Ethernet Connector: 8-pin M12 MicroChange socket

Digital Display: 2X20 Alphanumeric characters Beeper: Configurable LEDs: I/O status, Serial

SAFETY CERTIFICATIONS DESIGNED FOR

EN 55022:1998 Class A

MECHANICAL Length: 7.3” (184 mm) Width: 6.3” (160 mm) Height: 2.8” (71 mm) Weight: 1.6 lb. (726 g)

ENVIRONMENTAL Enclosure: IP65 Humidity: up to 90% (non-condensing) Operating Temperature: 0° to 50° C (32° to 122°F) Storage Temperature: -30° to 70° C (-22° to 158°F)

ELECTRICAL

TERMINAL BLOCKS MAX RATING J1-J8 Wire Range: 26 to 14 AWG. Wire Strip Length: 11 mm J9-J15 Wire Range: 22 to 18 AWG. Wire Strip Length: 5 mm J2-J5 Max Voltage: 28 VDC. Max Current: 4 Amps J6-J8 Max Voltage: 240 VAC. Max Current: 3 Amps

Power: 10-28 V

COMMUNICATION PROTOCOLS

PLUGGABLE RELAY MODULEACCESS CGBK1Pluggable Relay ModuleK2Pluggable Relay ModuleK3Pluggable Relay Module

Standard Interface: RS-232, RS-422

FCC, UL/cUL, CE, BSMI

ROHS/WEEE COMPLIANT ISO CERTIFICATION

Certified ISO 9001:2008 Quality Management System ©2015 Microscan Systems, Inc. SP022H-EN-1013 Warranty–For current warranty information on this product, please visit www.microscan.com/warranty.

Small: Access diameter range 0.18” to 0.39” (4.5 to 10 mm) Large: Access diameter range 0.2” to 0.5” (5 to 12.7 mm)

INPUTS/OUTPUTS J1Input Power 10-28 VDCJ2Output Power 10-28 VDCJ3ChassisJUMPERSJ4Output Power 10-28 VDCJP1Relay Output 1 OptionsJ5Output Power 10-28 VDCJP2Relay Output 2 OptionsJ6Output 1JP3Relay Output 3 OptionsJ7Output 2JP 11Trigger Button LockoutJ8Output 3JP 10

New Master Button Lockout

Microscan Systems Inc. Tel 425 226 5700 / 800 251 7711 Fax 425 226 8250

Microscan EuropeJ9RS 422/485J10Trigger/New MasterJ11Input 1SW1On/OffJ13Host RS-232SW2Reader Default

Tel 65 6846 1214 / Fax 65 6846 4641

J14Aux RS 232SW3Display Comm SwitchesJ15MS-Q 5 VDCSW5

Reader Output Indicators

www.microscan.comJ16SpareSW7Reader Ethernet Option

Tel 31 172 423360 / Fax 31 172 423366

SWITCHES